Large Stroke, Picometer Resolution Hexapod for Dynamic Mirror Positioning

Viewgraph presentation reviews the Fast Picometer Mirror mounting (FPMM) for the Terrestrial Planet Finder Coronagraph (TPF-C). Included in the presentation are slides with an overviews of the TPF-C, the requirements of the FPMM, the selection of the materials using the ACE system, and the architecture of the FPMM.

Ohl, Raymond G.

Highlights of the ASPE 2004 Winter Topical Meeting on Free-Form Optics: Design, Fabrication, Metrology, Assembly

We present highlights from the American Society for Precision Engineering's 2004 winter topical meeting entitled Free-Form Optics: Design, Fabrication, Metrology, Assembly. We emphasize those papers that are most relevant to astronomical optics. Optical surfaces that transcend the bounds of rotational symmetry have been implemented in novel optical systems with fantastic results since the release of Polaroid's first instant camera. Despite these successes, free-form optics have found only a few niche applications and have yet to enter the mainstream. The purpose of this meeting is to identify the state of the art of free-form optics design, fabrication, metrology and assembly and to identify the technical and logistical challenges that inhibit their widespread use. Issues that will be addressed include: What are free-form optics? How can optical systems be made better with free-form optics? How can designers use free-form optics? How can free-form optics be fabricated? How can they be measured? How are free-form optical systems assembled? Control of multi-axis systems.

Ohl, Raymond G.

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.

Effects of Forged Stock and Pure Aluminum Coating on Cryogenic Performance of Heat Treated Aluminum Mirrors

We present the results of an on-going test program designed to empirically determine the effects of different stress relief procedures for aluminum mirrors. Earlier test results identified a preferred heat treatment for flat and spherical mirrors diamond turned from blanks cut out of Al 6061-T651 plate stock. Further tests have been performed on mirrors from forged stock and one set from plate stock coated with Alumiplate(trademark) aluminum coating to measure the effect of these variables on cryogenic performance. The mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for three thermal cycles. We correlate the results of our optical testing with heat treatment and metallographic data.

Toland, Ronald W.

Optomechanical Alignment of the Grating Wheel Mechanism for a Ground-based, Cryogenic, Near-Infrared Astronomy Instrument

We describe the population, optomechanical alignment, and alignment verification of near-infrared gratings on the grating wheel mechanism (GWM) for the Infrared Multi- Object Spectrometer (IRMOS). IRMOS is a cryogenic (80 K) facility instrument for the Mayall Telescope (3.8 m) at Kitt Peak National Observatory and a MEMS spectrometer concept demonstrator for NASA's James Webb Space Telescope. The IRMOS optics, bench, and mechanisms are predominantly made of Al 6061 -T651. The GWM consists of 13 planar diffraction gratings and one flat imaging mirror (58 x 57 mm), each mounted at a unique compound angle on a 31.8 cm diameter gear. The Al 6061 grating substrates are stress relieved for enhanced cryogenic performance and the optical surface is replicated from an off-the-shelf master. The imaging mirror is diamond turned and post-polished. The grating mechanism spans a projected diameter of approximately 48cm when fully assembled, utilizes several flexure designs throughout the system to accommodate thermal gradient situations, and is controlled using custom software with an off-the-shelf controller. Each optic is aligned in six degrees of freedom relative to the GWM coordinate system, which is defined relative to an optical alignment cube mounted at the center of the gear. The tip/tilt (Rx, Ry) orientation of a given grating is measured using the zero-order return from an autocollimating theodolite. Each optic's mount includes a one-piece shim located between the optic and the gear. The shim is machined to fine align each optic. We also describe alignment verification, where grating diffractive properties are compared to model predictions.

Gutkowski, Sharon M.

Ambient and Cryogenic Alignment Verification and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a facility instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low- to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial Micro Electro-Mechanical Systems (MEMS) Digital Micro-mirror Device (DMD) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and the ambient and cryogenic imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve to venfy alignment, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides further verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides spectral lines at 546.1 nm and 1550 nm, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard test results validate this prediction. We conclude with an instrument performance prediction for first light.

Connelly, Joseph A.

Effects of Forged Stock and Pure Aluminum Coating on Cryogenic Performance of Heat Treated Aluminum Mirrors

In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress that may relieve and distort mirror figure to unacceptable levels at cryogenic operating temperatures unless relieved during fabrication. Cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of an on-going test program designed to empirically determine the effects of different stress relief procedures for aluminum mirrors. Earlier test results identified a preferred heat treatment for flat and spherical mirrors diamond turned from blanks cut out of Al6061-T651 plate stock. Further tests have been performed on mirrors from forged stock and one set from plate stock coated with Alumiplate(TM) aluminum coating to measure the effect of these variables on cryogenic performance. The mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for three thermal cycles. We correlate the results of our optical testing with heat treatment and metallographic data.

Toland, Ronald

Alignment of the Grating Wheel Mechanism for a Ground-Based, Cryogenic, Near-Infrared Astronomy Instrument

We describe the population, optomechanical alignment, and alignment verification of near-infrared gratings on the grating wheel mechanism (GWM) for the Infrared Multi-Object Spectrometer (IRMOS). IRMOS is a cryogenic (80 K), principle investigator-class instrument for the 2.1 m and Mayall 3.8 m telescopes at Kitt Peak National Observatory, and a MEMS spectrometer concept demonstrator for the James Webb Space Telescope. The GWM consists of 13 planar diffraction gratings and one flat imaging mirror (58 x 57 mm), each mounted at a unique compound angle on a 32 cm diameter gear. The mechanism is predominantly made of Al 6061. The grating substrates are stress relieved for enhanced cryogenic performance. The optical surfaces are replicated from off-the-shelf masters. The imaging mirror is diamond turned. The GWM spans a projected diameter of approx. 48 cm when fully assembled, utilizes several flexure designs to accommodate potential thermal gradients, and is controlled using custom software with an off-the-shelf controller. Under ambient conditions, each grating is aligned in six degrees of freedom relative to a coordinate system that is referenced to an optical alignment cube mounted at the center of the gear. The local tip/tilt (Rx/Ry) orientation of a given grating is measured using the zero-order return from an autocollimating theodolite. The other degrees of freedom are measured using a two-axis cathetometer and rotary table. Each grating's mount includes a one-piece shim located between the optic and the gear. The shim is machined to fine align each grating. We verify ambient alignment by comparing grating difractive properties to model predictions.

Gutkowski, Sharon M.

Integration, Testing and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator-class instrument for the Kitt Peak National Observatory 2.1 m and Mayall 3.8 m telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = lambda/delta lambda = 300 - 3000). On the 3.8 m telescope, IRMOS produces simultaneous spectra of approximately 100 objects in its approximately 3 x 2 arcmin field of view using a commercial micro electro-mechanical systems (MEMS) digital micro-mirror device (DMD) from Texas Instruments. The multi-mirror array DMD operates as a real-time programmable slit mask. The all-reflective optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the DMD field stop, and the spectrograph images the DMD onto a large-format detector. The instrument operates at approximately 80 K, cooled by a single electro-mechanical cryocooler. The bench and all components are made from aluminum 6061-T651. There are three cryogenic mechanisms. We describe laboratory integration and test of IRMOS before shipment to Kitt Peak. We give an overview of the optical alignment technique and integration of optical, mechanical, electrical and cryogenic subsystems. We compare optical test results to model predictions of point spread function size and morphology, contrast, and stray light. We discuss some lessons learned and conclude with a prediction for performance on the telescope.

Ohl, Raymond G.

Subsystem Imaging Performance and Modeling of the Infrared Multi-Object Spectrograph

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter). IRMOS is a near-IR (0.8 - 2.5 micron) spectrograph with low to mid resolution (R=lambda/delta, lambda = 300 - 3800). The IRMOS spectrograph produces simultaneous spectra of - 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial MEMS multi-mirror array device (MMA). The IRMOS optical design consists of two imaging systems, or "stages." The focal reducer, stage one, images the focal plane of the telescope onto the MMA. The spectrograph, stage two, images the MMA onto the detector. We describe the breadboard alignment method and imaging and scattered light performance for both the focal reducer and spectrograph. This testing provides verification of the optomechanical alignment method, and a measurement of the contribution of scattered light in the system due to mirror small scale surface error. After the stage I and 2 optics are integrated with the instrument, our test results will make it possible to distinguish between scattered light from the mirrors and the MMA. Image testing will be done at four wavelengths in the visible and near-IR. A mercury-argon pencil lamp will provide spectral lines at 546.1 and 1012 nm, and a blackbody radiation source lines at 1600 and 2200 nm. A CCD camera will be used as a detector for the visible wavelengths, and an IR photodiode will be used for the IR wavelengths. We compare our data with a theoretical analysis using a commercial software package. Mirror surface error is modeled by treating each surface as a superposition of various gratings (e.g., diamond turning tool marks, features due to the impurities of Al 6061, and periodic mid-frequency errors due to drift during machining).

Connelly, Joseph A.

Comparison of Stress Relief Procedures for Cryogenic Aluminum Mirrors

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter) and an engineering prototype for a potential design for the Next Generation Space Telescope/Multi-Object Spectrograph. IRMOS is a low-to mid-resolution (R = lambda/delta-lambda = 300-3800), near-IR (0.8-2.5 micron) spectrograph which produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arcmin field of view using a commercial MEMS multimirror array device. The instrument operating temperature is 80 K and the design is athermal --- the optical bench and mirrors are machined from aluminum 6061-T651. In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress, which, unless relieved during fabrication, may relieve and distort mirror figure to unacceptable levels at the operating temperature. Other cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of a test program designed to empirically determine the best stress relief procedure for the IRMOS mirrors. Identical test mirrors with spherical and flat optical prescriptions are processed with five different heat treatment formulae from the literature and compared to samples with out any additional processing. After figuring via diamond turning, the mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for several thermal cycles. The heat treatment procedure for the mirrors that yielded the least and most repeatable change in figure error and radius is applied to the IRMOS mirror blanks. We correlate the results of our optical testing with heat treatment and metallographic data.

Ohl, Raymond G.

Design, Fabrication, Optical Testing, and Performance of Diamond Machined Aspheric Mirrors for Ground-Based Near-IR Astronomy

Challenges in fabrication and testing have historically limited the choice of surfaces available for the design of reflective optical instruments. Spherical and conic mirrors are common, but, for future science instruments, more degrees of freedom are necessary to meet challenging performance and packaging requirements. These instruments will be composed of unusual aspheres located far off-axis with large spherical departure, and some designs will require asymmetric surface profiles. In particular, single-surface astigmatism correction in spectrographs necessitates a toroidal surface, which lacks an axis of rotational symmetry. We describe the design, fabrication, optical testing, and performance of three rotationally symmetric, off-axis, aspheric mirrors and one toroidal, off-axis, biconic camera mirror on aluminum substrates for the Infrared Multi-Object Spectrograph (IRMOS) instrument. IRMOS is a facility instrument for the Kitt Peak National Observatory's Mayall Telescope (3.8 m) and an engineering prototype for a possible design of the Next Generation Space Telescope/Multi-Object Spectrograph. The symmetric mirrors range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. They are various off-axis, convex and concave, prolate and oblate ellipsoids. The concave biconic mirror has a 94x76 mm aperture, Rx=377 mm, kx=0.0778, Ry=407 mm, and ky=0.1265 and is decentered. by -2 mm in x and 227 mm in y. The mirrors have an aspect ratio of approximately 4:1. The surface error fabrication tolerances are less than 63.3 nm RMS figure error and less than 10 nm RMS microroughness. The mirrors are attached to the instrument bench via a semi-kinematic, integral flexure mount. We describe mirror design, diamond machining, the results of figure testing using computer-generated holograms, and imaging and scattered light modeling and performance.

Ohl, Raymond G.

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John

UIT Observations of Early-Type Galaxies and Analysis of the FUSE Spectrum of a Subdwarf B Star

This work covers Ultraviolet Imaging Telescope (UIT) observations of early-type galaxies (155 nm) and Far Ultraviolet Spectroscopic Explorer (FUSE) spectra of a Galactic subdwarf B star (sdB). Early UV space astronomy missions revealed that early-type galaxies harbor a population of stars with effective temperatures greater than that of the main sequence turn-off (about 6,000 K) and UV emission that is very sensitive to characteristics of the stellar population. We present UV (155 nm) surface photometry and UV-B color profiles for 8 E and SO galaxies observed by UIT. Some objects have de Vaucouleurs surface brightness profiles, while others have disk-like profiles, but we find no other evidence for the presence of a disk or young, massive stars. There is a wide range of UV-B color gradients, but there is no correlation with metallicity gradients. SdB stars are the leading candidate UV emitters in old, high metallicity stellar populations (e.g., early-type galaxies). We observed the Galactic sdB star PG0749+658 with FUSE and derived abundances with the aim of constraining models of the heavy element distribution in sdB atmospheres. All of the elements measured are depleted with respect to solar, except for Cr and Mn, which are about solar, and Ni, which is enhanced. This work was supported in part by NASA grants NAG5-700 and NAG5-6403 to the University of Virginia and NAS5-32985 to Johns Hopkins University.

Ohl, Raymond G.

Optical Performance Modeling of FUSE Telescope Mirror

We describe the Metrology Data Processor (METDAT), the Optical Surface Analysis Code (OSAC), and their application to the image evaluation of the Far Ultraviolet Spectroscopic Explorer (FUSE) mirrors. The FUSE instrument - designed and developed by the Johns Hopkins University and launched in June 1999 is an astrophysics satellite which provides high resolution spectra (lambda/Delta(lambda) = 20,000 - 25,000) in the wavelength region from 90.5 to 118.7 nm The FUSE instrument is comprised of four co-aligned, normal incidence, off-axis parabolic mirrors, four Rowland circle spectrograph channels with holographic gratings, and delay line microchannel plate detectors. The OSAC code provides a comprehensive analysis of optical system performance, including the effects of optical surface misalignments, low spatial frequency deformations described by discrete polynomial terms, mid- and high-spatial frequency deformations (surface roughness), and diffraction due to the finite size of the aperture. Both normal incidence (traditionally infrared, visible, and near ultraviolet mirror systems) and grazing incidence (x-ray mirror systems) systems can be analyzed. The code also properly accounts for reflectance losses on the mirror surfaces. Low frequency surface errors are described in OSAC by using Zernike polynomials for normal incidence mirrors and Legendre-Fourier polynomials for grazing incidence mirrors. The scatter analysis of the mirror is based on scalar scatter theory. The program accepts simple autocovariance (ACV) function models or power spectral density (PSD) models derived from mirror surface metrology data as input to the scatter calculation. The end product of the program is a user-defined pixel array containing the system Point Spread Function (PSF). The METDAT routine is used in conjunction with the OSAC program. This code reads in laboratory metrology data in a normalized format. The code then fits the data using Zernike polynomials for normal incidence systems or Legendre-Fourier polynomials for grazing incidence systems. It removes low order terms from the metrology data, calculates statistical ACV or PSD functions, and fits these data to OSAC models for the scatter analysis. In this paper we briefly describe the laboratory image testing of FUSE spare mirror performed in the near and vacuum ultraviolet at John Hopkins University and OSAC modeling of the test setup performed at NASA/GSFC. The test setup is a double-pass configuration consisting of a Hg discharge source, the FUSE off-axis parabolic mirror under test, an autocollimating flat mirror, and a tomographic imaging detector. Two additional, small fold flats are used in the optical train to accommodate the light source and the detector. The modeling is based on Zernike fitting and PSD analysis of surface metrology data measured by both the mirror vendor (Tinsley) and JHU. The results of our models agree well with the laboratory imaging data, thus validating our theoretical model. Finally, we predict the imaging performance of FUSE mirrors in their flight configuration at far-ultraviolet wavelengths.

Saha, Timo T.

Hardware and Methods of the Optical End-to-End Test of the Far Ultraviolet Spectroscopic Explorer (FUSE)

The Far Ultraviolet Spectroscopic Explorer (FUSE), currently being tested and scheduled for a 1999 launch, is an astrophysics satellite designed to provide high spectral resolving power (Lambda/(Delta)Lambda = 24,000-30,000) over the interval 90.5-118.7 nm. The FUSE optical path consists of four co-aligned, normal incidence, off-axis parabolic, primary mirrors which illuminate separate Rowland circle spectrograph channels equipped with holographic gratings and delay line microchannel plate detectors. We describe the hardware and methods used for the optical end-to-end test of the FUSE instrument during satellite integration and test. Cost and schedule constraints forced us to devise a simplified version of the planned optical test which occurred in parallel with satellite thermal-vacuum testing. The optical test employed a collimator assembly which consisted of four co-aligned, 15" Cassegrain telescopes which were positioned above the FUSE instrument, providing a collimated beam for each optical channel. A windowed UV light source, remotely adjustable in three axes, was mounted at the focal plane of each collimator. Problems with the UV light sources, including high F-number and window failures, were the only major difficulties encountered during the test. The test succeeded in uncovering a significant problem with the secondary structure used for the instrument closeout cavity and, furthermore, showed that the mechanical solution was successful. The hardware was also used extensively for simulations of science observations, providing both UV light for spectra and visible light for the fine error sensor camera.

Conard, Steven J.