Quantifying spatial resolution in a fast neutron radiography system

Neutron imaging is a powerful nondestructive examination modality that has been employed in various applications. Fast neutrons provide advantages over lower energy neutrons, such as examining thicker samples and inducing negligible activation and transmutations. However, fast neutrons interact mostly via elastic scattering with both the neutron detector and the object, causing degradation in spatial resolution. This study explores the quantification of spatial resolution caused by the testing target itself and suggests proper candidate materials for characterizing spatial resolution in terms of modulation transfer function. Knife-edge radiographs of 3 mm, 6 mm, and 5 cm thick Tantalum (Ta) foils, and a 2.54 cm Tungsten (W) cube were acquired using a CCD-based imaging system and a Polyvinyl Toluene (PVT) scintillator at the Ohio State Research Reactor (OSURR)’s fast neutron beam facility. The spatial resolutions calculated were 195 ± 20 μm, 224 ± 22 μm, 248 ± 25 μm, and 435 ± 44 μm for 3 mm, 6 mm, and 5 cm Ta foils, and 2.54 cm W cube, respectively. The results showed a worsening spatial resolution with increasing target thickness. Simulations and calculations estimate that elastic scattering kinematics between neutrons and protons in the PVT medium also limits spatial resolution, and it sets a lower limit of ~44 μm on the spatial resolution for 2 MeV neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Parametric Evaluation of New Fast Neutron Scintillator Designs

Experiments conducted at Idaho National Laboratory (INL) measured the performance of prototype fast neutron scintillator screens with various scintillator materials deposited in a range of thicknesses on high density polyethylene (HDPE) of varying thickness. The HDPE acts as a converter for the fast neutrons, utilizing a proton recoil reaction to cause the scintillator material to emit photons. INL’s Neutron Radiography (NRAD) Reactor’s North Radiography Station (NRS) beamline has a fast neutron flux (above 1 MeV) greater than 1.5×107 n/cm2s. This study determined which combination of scintillator material and thickness, as well as which HDPE thickness, exhibited the best screen performance for fast neutron imaging based on light output and spatial resolution. The results of these measurements inform development of higher detection quantum efficiency screens for fast neutron imaging.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of polyvinyl toluene scintillators for fast neutron imaging

We evaluated here polyvinyl toluene (PVT) scintillators fabricated with different emitting dopants and scintillator optical configurations for fast neutron imaging. A neutron imaging apparatus was constructed to study scintillators under MeV neutron exposure. PVT with 2% Xylyl Flrpic emitter was identified as the brightest. The addition of a black backing to the scintillator, compared with a specular reflector film backing, improved the resolution of the neutron image obtained with the PVT scintillator by about 2 ×. It is concluded that a PVT imaging screen with 2% Xylyl Flrpic, configured with a black backing, provides the best quality fast neutron image of the scintillators tested.

36 MATERIALS SCIENCE↗