Search NASA⌕ Search

Engineering topics

Oldenburg, C. M.

Publications and source records attributed to Oldenburg, C. M..

Multi‐Layered Systems for Permanent Geologic Storage of CO 2 at the Gigatonne Scale

Abstract The effectiveness of Carbon Capture and Storage (CCS) as an imperative decarbonization technology relies on the sealing capacity of a fine‐grained caprock to permanently store CO 2 deep underground. Uncertainties in assessing the caprock sealing capacity increase with the spatial and temporal scales and may delay CCS deployment at the gigatonne scale. We have developed a computationally efficient transport model to capture the dynamics of basin‐wide upward CO 2 migration in a multi‐layered setting over geological time scales. We find that massive capillary breakthrough and viscous flow of CO 2 , even through pervasively fractured caprocks, are unlikely to occur and compromise the storage security. Potential leakage from the injection reservoir is hampered by repetitive layering of overlying caprocks. This finding agrees with geologic intuition and should be understandable by the public, contributing to the development of climate policies around this technology with increased confidence that CO 2 will be indefinitely contained in the subsurface.

58 GEOSCIENCES↗

Leakage From Coexisting Geologic Forcing and Injection‐Induced Pressurization: A Semi‐Analytical Solution for Multilayered Aquifers With Multiple Wells

Abstract Abnormal fluid pressures (above or below hydrostatic pressure) can develop and persist in sedimentary basins. The common occurrence of abnormal pressures may cause challenges for project permitting of geological carbon sequestration (GCS), particularly in reservoirs with pre‐injection overpressure. The leaky wells that may exist in some sedimentary basins can provide flow paths between deep brine aquifers and shallower freshwater aquifers. Pre‐injection relative overpressures can cause brine leakage through leaky wells even before any injection occurs. The tendency for flow through leaky wells is coupled with the process of pressure dissipation that occurs through aquitards. Specifically, with non‐zero permeability, aquitards can dissipate pressure over large areal extents and thereby reduce leakage rates through leaky wells. This study presents development of a semi‐analytical solution for hydraulic head and brine leakage in multilayered aquifer–aquitard systems with geologic pressure forcing. The geologic forcing that causes abnormal pressures in the multilayered system can coexist with any number of injection, extraction, and leaky wells that also affect fluid pressure. The semi‐analytical model is applied to explore how leakage through leaky wells varies as functions of pressurization rate, along with aquitard and leaky well properties in an overpressured multilayered system. The results show that although injection‐induced pressures can dissipate rapidly through suitably permeable aquitards, coexisting geologic forcing may create sustained rates of brine leakage into freshwater aquifers through leaky wells. In GCS, a very low‐permeability aquitard with high capillary entry pressure to free‐phase CO 2 is desired to serve as the caprock to prevent leakage of CO 2 from the storage reservoir. Nevertheless, the results from this study show that the brine leakage impact to shallow freshwater aquifers through leaky wells might substantially decrease with increasing aquitard permeability values, as long as small aquitard permeability and high capillary entry pressure serve to prevent CO 2 leakage.

Cihan, A.↗

Mechanistic modeling of CO 2 well leakage in a generic abandoned well through a bridge plug cement-casing gap

Both known and unmapped plugged and abandoned wells are potential leakage pathways for CO 2 from geologic carbon sequestration (GCS) sites. Although many abandoned wells have cement bridge plugs installed to prevent leakage, the seal between the cement and the inner casing wall is subject to failure. In this study, we carried out detailed T2Well simulations of cases of sudden non-Darcy flow of CO 2 and brine leakage up the gap between a cement plug and the inner steel casing wall that becomes a fully connected flow path during the post-injection period. The goal of our study was two-fold: (1) to understand the dynamics, rates, and the characteristic temporal signals associated with the onset of leakage through various gap-aperture sizes, and (2) to suggest potential monitoring strategies based on the findings. Simulation results show that the leakage of CO 2 and brine upward is transient with interesting phase interference behavior. Time-dependent oscillatory flows with varying pressure, temperature, and flow rates of CO 2 and brine show strong dependence on gap aperture. Phase-change and decompression lead to very low temperatures at the top of the well for gap apertures larger than 4 mm suggesting that remote thermal monitoring at the ground surface may be an effective way of monitoring even if well locations are not known a priori. Pressure in the well is also indicative of CO 2 leakage. The temporal patterns of changing temperature and pressure may be useful diagnostic signals for leakage detection. Finally, these transient leakage signals may provide information on the cause of leakage and/or characteristics of the flow path that could inform effective remediation design and execution approaches.

58 GEOSCIENCES↗