Preliminary results from the portable standard satellite laser ranging intercomparison with MOBLAS-7

Conventional Satellite Laser Ranging (SLR) instrumentation has been configured and successfully used to provide high-accuracy laboratory measurements on the LAGEOS-2 and TOPEX cube-corner arrays. The instrumentation, referred to as the Portable Standard, has also been used for field measurements of satellite ranges in tandem with MOBLAS-7. Preliminary results of the SLR measurements suggest that improved range accuracy can be achieved using this system. Results are discussed.

Selden, Michael↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

Test results from LAGEOS-2 optical characterization using pulsed lasers

The Laser Geodynamic Satellite-2 (LAGEOS-2) has undergone extensive optical testing at NASA Goddard Space Flight Center during 1989. The techniques included measuring the far field diffraction pattern using cw and pulsed lasers. In the pulsed measurement technique, response of the satellite was studied by measuring the far-field diffraction pattern (FFDP) as a function of pulsewidth, wavelength, polarization, position in the FFDP, detector/processing techniques, and satellite orientation. The purpose of the pulsed laser testing was two-fold: (1) to characterize the satellite optical response with the detector and signal processing electronics currently used in most SLR stations using the portable laser ranging standard, and (2) to characterize the satellite response for various conditions using the highest bandwidth optical detector (streak camera) available for the next generation of satellite laser ranging (SLR) technology. The portable ranging standard employed multiple measurement devices and an optical calibration scheme to eliminate range-dependent and amplitude-dependent systematics. These precautions were taken to eliminate/minimize instrumental errors and provide maximum accuracy. For LAGEOS orbit (6000 Km), ground stations are located 34 to 38 Mu radians off the axis of the return signal from the satellite; therefore, an optical mask was used to restrict the field of view (FOV) of detection to this annular region of the FFDP. The two measurement techniques were implemented using an aperture sharing scheme and complemented each other by providing mutual verification.

Varghese, Thomas K.↗

Optical attenuation mechanism upgrades, MOBLAS, and TLRS systems

This poster presentation describes the Optical Attenuation Mechanism (OAM) Upgrades to the MOBLAS and TLRS Crustal Dynamics Satellite Laser Ranging (CDSLR) systems. The upgrades were for the purposes of preparing these systems to laser range to the TOPEX/POSEIDON spacecraft when it will be launched in the summer of 1992. The OAM permits the laser receiver to operate over the expected large signal dynamic range from TOPEX/POSEIDON and it reduces the number of pre- and post-calibrations for each satellite during multi-satellite tracking operations. It further simplifies the calibration bias corrections that had been made due to the pass-to-pass variation of the photomultiplier supply voltage and the transmit filter glass thickness. The upgrade incorporated improvements to the optical alignment capability of each CDSLR system through the addition of a CCD camera into the MOBLAS receive telescope and an alignment telescope onto the TLRS optical table. The OAM is stepper motor and microprocessor based; and the system can be controlled either manually by a control switch panel or computer controlled via an EIA RS-232C serial interface. The OAM has a neutral density (ND) range of 0.0 to 4.0 and the positioning is absolute referenced in steps of 0.1 ND. Both the fixed transmit filter and the daylight filter are solenoid actuated with digital inputs and outputs to and from the OAM microprocessor. During automated operation, the operator has the option to overide the remote control and control the OAM system via a local control switch panel.

Eichinger, Richard↗

Performance comparison of high speed microchannel plate photomultiplier tubes

The transit time spread characteristics of high speed microchannel photomultipliers has improved since the upgrade of the NASA CDSLR network to MCP-PMT's in the mid-1980's. The improvement comes from the incorporation of 6 micron (pore size) microchannels and offers significant improvement to the satellite ranging precision. To examine the impact on ranging precision, two microchannel plate photomultiplier tubes (MCP-PMT) were evaluated for output pulse characteristics and temporal jitter. These were a Hamamatsu R 2566 U-7 MCP-PMT (6 micron) and an ITT 4129f MCP-PMT (12 micron).

Varghese, Thomas↗

High resolution vidicon-based readout system for photon-counting streak camera applications

The design, implementation, and evaluation of a high-resolution vidicon-based reconfigurable imaging system for integration into a photon-counting streak camera that can be readily coupled to a standard interface and computer have been achieved. Experimental results are reported which demonstrate that the design goals are met, providing the capability to measure differential time to better than 3 picosecond accuracy. Augmented by real-time calibration, the accuracy, linearity, noise levels, and stability of the system are adequate to support dual wavelength laser ranging.