An FPGA-based readout chip emulator for the CMS ETL detector upgrade

Here, we present an FPGA-based readout chip emulator board for the CMS Endcap Timing Layer (ETL) detector upgrade. The emulator board uses an Intel Cyclone 10 GX FPGA to emulate the digital functions of four Endcap Layer Readout Chips (ETROCs). Based on the actual ETROC design, the firmware is implemented and verified. The emulator board is being used for the ETROC digital design verification and system development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TDC with uncontrolled delay lines: calibration approaches and precision improvement methods

The time-to-digital-converter (TDC) using uncontrolled delay lines has a simple structure and finer measurement precision since the delay cells are pure digital gates that operate at maximum speed. For every incoming hit, two “snapshots” of the delay line are taken by the register array with two strobes separated with a known time interval. With two measurements, propagation delays of each cell in the delay line can be calibrated for the operating temperature and voltage. The two measurements can also be averaged to improve the TDC measurement precision. We will discuss various calibration approaches and present test results in this work.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In-pixel automatic threshold calibration for the CMS Endcap Timing Layer readout chip

We present the implementation and verification of an in-pixel automatic threshold calibration circuit for the CMS Endcap Timing Layer (ETL) in the High-Luminosity LHC upgrade. The discriminator threshold of the ETL readout chip (ETROC) needs to be calibrated regularly to mitigate the circuit baseline change. Traditional methods need a lot of communication through a slow control system hence are time-consuming. This paper describes an in-pixel automatic scheme with improvements in operating time and usability. In this scheme, a sample-accumulation circuit is used to measure the average discriminator output. A binary successive approximation and linear combination scan are applied to find the equivalent baseline. The actual calibration procedure has been first implemented in FPGA firmware and tested with the ETROC front-end prototype chip (ETROC0). The calibration circuit has been implemented with Triple Modular Redundancy (TMR) and verified with Single Event Effects (SEEs) simulation. A complete calibration process lasts 35 ms with a 40 MHz clock. In the worst case, the dynamic and static power consumption are estimated to be 300 uW and 10.4 uW, respectively. The circuit design, implemented in a 65 CMOS technology, will be integrated into ETROC2, the next iteration of the ETROC with a 16 x16 pixel matrix.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-center quadrature scheme for the molecular continuum

We report a common way to evaluate electronic integrals for polyatomic molecules is to use Becke’s partitioning scheme (Becke and Chem, 1988) in conjunction with overlapping grids centered at each atomic site. The Becke scheme was designed for integrands that fall off rapidly at large distances, such as those approximating bound electronic states. When applied to states in the electronic continuum, however, Becke scheme exhibits slow convergence and it is highly redundant. Here, we present a modified version of Becke scheme that is applicable to functions of the electronic continuum, such as those involved in molecular photoionization and electron–molecule scattering, and which ensures convergence and efficiency comparable to those realized in the calculation of bound states. In this modified scheme, the atomic weights already present in Becke’s partition are smoothly switched off within a range of few bond lengths from their respective nuclei, and complemented by an asymptotically unitary weight. The atomic integrals are evaluated on small spherical grids, centered on each atom, with size commensurate to the support of the corresponding atomic weight. The residual integral of the interstitial and long-range region is evaluated with a central master grid. The accuracy of the method is demonstrated by evaluating integrals involving integrands containing Gaussian Type Orbitals and Yukawa potentials, on the atomic sites, as well as spherical Bessel functions centered on the master grid. These functions are representative of those encountered in realistic electron-scattering and photoionization calculations in polyatomic molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scrape-off layer transport and filament characteristics in high-density tokamak regimes

A detailed cross-device investigation on the role of filamentary dynamics in high-density regimes has been performed within the EUROfusion framework, comparing the ASDEX Upgrade (AUG) and TCV tokamaks. Both devices run density ramp experiments at different levels of plasma current, keeping the toroidal field or q 95 constant in order to disentangle the role of the parallel connection length and the current. During the scan at a constant toroidal field, in both devices the scrape-off layer (SOL) profiles tend to develop a clear SOL density shoulder at a lower edge density whenever the current is reduced. Different current behaviour is substantially reconciled in terms of the edge density normalized to the Greenwald fraction. During the scan at constant q 95 AUG exhibits similar behaviour, whereas in TCV no upstream profile modification signature has been observed at lower current levels. The latter behaviour has been ascribed to the lack of target density rollover. In this work, the relation between the upstream density profile modification and detachment condition has been investigated. For both devices the relation between blob size and the SOL density e-folding length is found independent of the plasma current, with the observation of a clear increase in blob size and the edge density normalized to a Greenwald fraction. ASDEX Upgrade has also explored filamentary behaviour in the H-mode. The experiments in AUG have focused on the role of neutrals, performing discharges with and without cryogenic pumps, highlighting how high neutral pressure, not only in the divertor but also at the midplane, is needed in order to develop an H-mode SOL profile shoulder in AUG.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VIPRAM_L1CMS: a 2-Tier 3D Architecture for Pattern Recognition for Track Finding

In HEP tracking trigger applications, flagging an individual detector hit is not important. Rather, the path of a charged particle through many detector layers is what must be found. Moreover, given the increased luminosity projected for future LHC experiments, this type of track finding will be required within the Level 1 Trigger system. This means that future LHC experiments require not just a chip capable of high-speed track finding but also one with a high-speed readout architecture. VIPRAM_L1CMS is 2-Tier Vertically Integrated chip designed to fulfill these requirements. It is a complete pipelined Pattern Recognition Associative Memory (PRAM) architecture including pattern recognition, result sparsification, and readout for Level 1 trigger applications in CMS with 15-bit wide detector addresses and eight detector layers included in the track finding. Pattern recognition is based on classic Content Addressable Memories with a Current Race Scheme to reduce timing complexity and a 4-bit Selective Precharge to minimize power consumption. VIPRAM_L1CMS uses a pipelined set of priority-encoded binary readout structures to sparsify and readout active road flags at frequencies of at least 100MHz. VIPRAM_L1CMS is designed to work directly with the Pulsar2b Architecture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE DARK ENERGY CAMERA

The Dark Energy Camera is a new imager with a 2.°2 diameter field of view mounted at the prime focus of the Victor M. Blanco 4 m telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five-element optical corrector, seven filters, a shutter with a 60 cm aperture, and a charge-coupled device (CCD) focal plane of 250 μm thick fully depleted CCDs cooled inside a vacuum Dewar. The 570 megapixel focal plane comprises 62 2k × 4k CCDs for imaging and 12 2k × 2k CCDs for guiding and focus. The CCDs have 15 μm × 15 μm pixels with a plate scale of 0.″263 pixel{sup −1}. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 s with 6–9 electron readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and testing of the first 2D Prototype Vertically Integrated Pattern Recognition Associative Memory

An associative memory-based track finding approach has been proposed for a Level 1 tracking trigger to cope with increasing luminosities at the LHC. The associative memory uses a massively parallel architecture to tackle the intrinsically complex combinatorics of track finding algorithms, thus avoiding the typical power law dependence of execution time on occupancy and solving the pattern recognition in times roughly proportional to the number of hits. This is of crucial importance given the large occupancies typical of hadronic collisions. The design of an associative memory system capable of dealing with the complexity of HL-LHC collisions and with the short latency required by Level 1 triggering poses significant, as yet unsolved, technical challenges. For this reason, an aggressive R&D program has been launched at Fermilab to advance state of-the-art associative memory technology, the so called VIPRAM (Vertically Integrated Pattern Recognition Associative Memory) project. The VIPRAM leverages emerging 3D vertical integration technology to build faster and denser Associative Memory devices. The first step is to implement in conventional VLSI the associative memory building blocks that can be used in 3D stacking, in other words, the building blocks are laid out as if it is a 3D design. In this paper, we report on the first successful implementation of a 2D VIPRAM demonstrator chip (protoVIPRAM00). The results show that these building blocks are ready for 3D stacking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-142: Performance Study of Automatic Image-Segmentation Algorithms in Motion Tracking Via MR-IGRT

Purpose: Evaluate commonly used segmentation algorithms on a commercially available real-time MR image guided radiotherapy (MR-IGRT) system (ViewRay), compare the strengths and weaknesses of each method, with the purpose of improving motion tracking for more accurate radiotherapy. Methods: MR motion images of bladder, kidney, duodenum, and liver tumor were acquired for three patients using a commercial on-board MR imaging system and an imaging protocol used during MR-IGRT. A series of 40 frames were selected for each case to cover at least 3 respiratory cycles. Thresholding, Canny edge detection, fuzzy k-means (FKM), k-harmonic means (KHM), and reaction-diffusion level set evolution (RD-LSE), along with the ViewRay treatment planning and delivery system (TPDS) were included in the comparisons. To evaluate the segmentation results, an expert manual contouring of the organs or tumor from a physician was used as a ground-truth. Metrics value of sensitivity, specificity, Jaccard similarity, and Dice coefficient were computed for comparison. Results: In the segmentation of single image frame, all methods successfully segmented the bladder and kidney, but only FKM, KHM and TPDS were able to segment the liver tumor and the duodenum. For segmenting motion image series, the TPDS method had the highest sensitivity, Jarccard, and Dice coefficients in segmenting bladder and kidney, while FKM and KHM had a slightly higher specificity. A similar pattern was observed when segmenting the liver tumor and the duodenum. The Canny method is not suitable for consistently segmenting motion frames in an automated process, while thresholding and RD-LSE cannot consistently segment a liver tumor and the duodenum. Conclusion: The study compared six different segmentation methods and showed the effectiveness of the ViewRay TPDS algorithm in segmenting motion images during MR-IGRT. Future studies include a selection of conformal segmentation methods based on image/organ-specific information, different filtering methods and their influences on the segmentation results. Parag Parikh receives research grant from ViewRay. Sasa Mutic has consulting and research agreements with ViewRay. Yanle Hu receives travel reimbursement from ViewRay. Iwan Kawrakow and James Dempsey are ViewRay employees.