Search NASA⌕ Search

Engineering topics

Olson, John E

Publications and source records attributed to Olson, John E.

Radioactive Cesium Isotope Ratios as a Tool for determining Dispersal and Re-dispersal Mechanisms Downwind from the Nevada Nuclear Security Site

Fractionation of the two longer lived radioactive cesium isotopes (135 and 137) produced by above ground nuclear tests have been measured and used to clarify the dispersal mechanisms of cesium deposited in the area between the Nevada Nuclear Security Site (NNSS) and Lake Mead in the southwestern United States. Fractionation of these isotopes is due to the 135 decay chain requiring several days to completely decay to Cs and the 137 decay chain less than one hour. Since the Cs precursors are gases, iodine and xenon, the 135Cs plume was deposited farther downwind than the 137Cs plume. Samples were obtained from the Las Vegas arm of Lake Mead, separated into segments, gamma counted to identify layers of activity and analyzed for 135Cs/137Cs ratios. The layers proved to have nearly identical highly fractionated isotope ratios. This information is consistent with a model where the cesium was initially deposited onto the land area draining into Lake Mead and the composite from all the above ground shots subsequently washed onto the Lake by high intensity rain and windstorms producing a layering of Cs activity where each layer is a portion of the composite.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multi-collector Isotope Ratio Mass Spectrometer -- Operational Performance Report

This report describes the operational testing of a new magnetic sector mass spectrometer that utilizes seven full-sized discrete dynode electron multipliers operating simultaneously. The instrument includes a newly developed ion dispersion lens that enables the mass dispersed individual isotope beams to be separated sufficiently to allow a full-sized discrete dynode pulse counting multiplier to be used to measure each isotope beam. The performance of the instrument was measured using SRM 996 (244Pu spike) at loadings of 2.4 and 12 fg on resin beads and with SRM 4350B Columbia River Sediment samples. The measured limit of detection (3s) for 240Pu was 3.4 attograms for SRM 996. The limit of quantitation (LOQ), defined as 10 s, was 11.2 attograms. The measured concentration of 239Pu in the CRS standard was 152 ± 6 fg/g.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion mobility spectrometers and methods for ion mobility spectrometry

An ion mobility spectrometer may include an inner electrode and an outer electrode arranged so that at least a portion of the outer electrode surrounds at least a portion of the inner electrode and defines a drift space therebetween. The inner and outer electrodes are electrically insulated from one another so that a non-linear electric field is created in the drift space when an electric potential is placed on the inner and outer electrodes. An ion source operatively associated with the ion mobility spectrometer releases ions to the drift space defined between the inner and outer electrodes. A detector operatively associated with at least a portion of the outer electrode detects ions from the drift space.

47 OTHER INSTRUMENTATION↗

Continuous sampling ion mobility spectrometers and methods therefor

An ion mobility spectrometer may include a flow channel having an inlet end and an outlet end. A deflection electrode is positioned within the flow channel so that a non-linear electric field is created between at least a portion of the flow channel and at least a portion of the deflection electrode when an electrostatic potential is placed across the deflection electrode and the flow channel. The ion mobility spectrometer also includes means for producing ions at a position upstream from the leading edge of the deflection electrode, so that ions produced thereby are deflected by the deflection electrode into the non-linear electric field. A detector positioned within the flow channel for detects ions from the non-linear electric field.

47 OTHER INSTRUMENTATION↗