Search NASA⌕ Search

Engineering topics

Olson, R.

Publications and source records attributed to Olson, R..

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock and compression-bang time at the NIF [National Ignition Facility]

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using DHe-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase DHe-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock and compression-bang times in DHe-filled surrogate implosions at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiative Energy Budget Studies Using Observations from the Earth Radiation Budget Experiment (ERBE)

Our research activities under this NASA grant have focused on two broad topics associated with the Earth Radiation Budget Experiment (ERBE): (1) the role of clouds and the surface in modifying the radiative balance; and (2) the spatial and temporal variability of the earth's radiation budget. Each of these broad topics is discussed separately in the text that follows. The major points of the thesis are summarized in section 3 of this report. Other dissertation focuses on deriving the radiation budget over the TOGA COARE region.

Ackerman, Steven A.↗

Weld-Wire Monitor

Changes in the size or composition of weld wire being fed to an automatic welding machine are detected by an impedance-monitoring instrument. The instrument triggers an alarm if the changes would affect weld quality or cause weld failure. Device could find applications in construction of pipelines or nuclear powerplants.

Olson, R.↗

Solar weather/climate predictions

Solar variability influences upon terrestrial weather and climate are addressed. Both the positive and negative findings are included and specific predictions, areas of further study, and recommendations listed.

Schatten, K. H.↗