Search NASA⌕ Search

Engineering topics

Ordonez, Juan C.

Publications and source records attributed to Ordonez, Juan C..

Performance Assessment of Pakistani Central Receiver Plant Case Study Using Aimpoint Strategy Optimization Tools

Pakistan has a high potential for both photovoltaic and Concentrated Solar Power (CSP) deployment to meet its energy requirements. Previous feasibility studies have shown that a variety of CSP technologies are both technically and economically viable in the Pakistani climate and can significantly mitigate the country's current lack of grid reliability. This work aims to enhance the performance of a previously designed Central Receiver System (CRS) plant for Pakistan using state-of-the-art aimpoint optimization methods. Results from our case study show that optimized aiming strategies have increased practicality due to their adherence to flux limitations on the receiver, and offer ~2.4% more thermal energy delivered to the receiver for the Pakistani case study compared to modern performance characterization software, translating to up to 149 additional hours of nameplate-capacity production to address the shortfall in an electricity-starved market.

central receiver system↗

Low-temperature solar thermal-power systems for residential electricity supply under various seasonal and climate conditions

In this work, the performance of low-temperature (<100 degrees C) solar thermal-power systems to satisfy residential electric loads was analyzed. The solar-driven system was designed to provide a fraction of the total electricity demand in a complementary operation with the electric grid. The analysis was conducted for an coperation during seven days each season, considering real solar and climate variables and residential loads at different climate zones in the United States. The efficiency of the system strongly depends on the solar radiation profile and the ambient temperature. Maximum efficiencies of around 9.5% were obtained in the cold and marine climate zones due to the high solar energy input and low heat dissipation temperatures. In these two zones, the system could supply more than 98% of the electricity demand all seasons. At mixed-humid and hot-humid regions, the system supplied around 50% of the electric load in three of the four seasons, but it only supplies about 27% of the electricity needs in the mixed-humid zone during summer and hot-humid zone during winter. The effect of the solar collector field area and the tank volume was also analyzed. In general, larger solar fields positively impact the efficiency. However, the impact of the tank volume varies depending on the solar radiation profile and the load requirements. Average efficiencies for the seven-day operation can be larger than 6% with a proper selection of the solar collector area and tank volume for an Organic Rankine Cycle with a capacity of about 2.6 kW. Finally, an economic analysis of the system was conducted, and the results were compared with a solar PV + battery system of similar capacity. It is expected that the cost for the analyzed solar-thermal system decreases in the coming years with the increased interest on low temperature applications.

14 SOLAR ENERGY↗

Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

Influence of Correlations on the Thermal Performance Modeling of Parabolic Trough Collectors

The influence of correlations on the thermal performance modeling of parabolic trough collectors was analyzed in this work. A versatile model for a parabolic trough collector was developed that allows one- and two-dimensional analysis and enables the use of correlations to calculate thermophysical properties and convection heat transfer coefficients. The model also allows the use of constant values for properties and/or coefficients obtained from the evaluation correlations at a specific temperature. The effect of each correlation was evaluated independently, and the results were compared with a reference case that considered a two-dimensional approach and used all the correlations. For the analyzed cases, the correlation for the absorber emittance has the strongest impact on the collector efficiency, leading to a lower error when used. Based on the results, a one-dimensional model approach considering a correlation for the absorber emittance leads to efficiency errors below 3% for collector lengths of up to 243.6 m. Compared with the reference case, a one-dimensional approach using all correlations for a collector with a length of 500 m, and operating with an inlet temperature of 773 K, can result in errors around 9%. However, using constant values for properties and heat transfer coefficients could lead to errors of up to 50%. Multiple thermal models for parabolic trough collectors proposed in the literature rely on a one-dimensional approach, estimated values for the heat transfer coefficients, and constant thermophysical properties. The errors associated with those approaches are analyzed and quantified in this work as a function of the collector length and operation temperature.

absorber emittance↗

Energy, Exergy, Entropy Generation Minimization, and Exergoenvironmental Analyses of Energy Systems-A Mini-Review

Meeting the growing energy demands has become a crucial challenge, which should employ energy integration and benefit from the extraction of the maximum thermodynamic potential of the resources consumed. This brief review presents an overview of the essential elements of the methods of energy, exergy, entropy generation minimization, and exergoenvironmental analyses. In combination, these methodologies constitute a powerful toolbox for the design, analysis, and optimization of energy systems. The quantification of energy and environmental impacts provided by them is essential in guiding toward system designs that are consistent with current energy and environmental needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermodynamic Modeling of Heat Engines Including Heat Transfer and Compression–Expansion Irreversibilities

In this paper, a thermodynamic model based on an endoreversible engine approach is developed to analyze the performance of heat engines operating under different thermodynamic cycles. The model considers finite heat transfer rate, variable heat source and sink temperatures, and irreversibilities associated with the expansion and compression. Expressions for the maximum power and efficiency at maximum power output are obtained as a function of hot and cold reservoir temperatures, the equivalent isentropic efficiency of compression and expansion components, and the effective conductance ratio between heat exchangers. In all cases, the Curzon–Ahlborn efficiency is retrieved at constant reservoir temperatures and neglected compression–expansion irreversibilities. The proposed model allows assessing the effect of isentropic efficiencies and heat exchanger design and operation characteristics for different thermodynamic cycles.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of the concentration ratio on energetic and exergetic performance of concentrating solar collectors with integrated transparent insulation materials

The effect of the concentration ratio on the performance of parabolic trough and central receiver collectors with integrated Transparent Insulation Materials (TIMs) is analyzed in this work. A model based on optical, energy, and exergy analyses is developed to determine thermal and second law efficiencies of concentrated solar collectors as a function of the absorber temperature and concentration ratio. The results are compared with the respective traditional collector configurations without TIM. In general, high concentration ratios are fundamental to maintain high efficiencies. The incorporation of a TIM into concentrated solar collectors leads to higher thermal efficiencies at high operating temperatures even at low concentration ratios. An equivalent second law efficiency to that of the reference collector configuration can be achieved at lower concentration ratios by incorporating a TIM in parabolic trough or a TIM and a glass envelope in central receiver collectors. As a result, the idea of using a TIM deserves further exploration as it seems to be a promising alternative that contributes to a more efficient and cost-effective technology.

14 SOLAR ENERGY↗