An analytical solution to obtain the optimum source location using multiple direction finders on a spherical surface

An analytical solution is presented for determining the optimum location of a radiating source on the surface of a sphere, given multiple bearings. The bearings are assumed to have small errors of the order of 0-10 deg. The optimum location is found by minimizing the sum of the squares of the perpendicular great-circle distances from the source to the bearing lines. This is achieved analytically through an eigenvalue approach, rather than the usual iterative, numerical approach. Bearings of different weight are taken into account by approximating the distance from each direction finder to the source. The result is general and may have wide application. Since it is simple and nearly as fast as the triangulation technique for source location, it is now used in the SUNY-Albany East Coast Lightning Detection Network to compute the optimum location for lightning in real time.

Orville, Richard E., Jr.↗

Cloud-to-ground lightning flash characteristics from June 1984 through May 1985

A magnetic direction-finding network for the detection of lightning cloud-to-ground strikes has been installed along the east coast of the United States. Time, location, flash polarity, stroke count, and peak signal amplitude are recorded in real time. The data were recorded from Maine to North Carolina and as far west as Ohio; analyses were restricted to flashes within 300 km of a direction finder. Measurements of peak signal strength have been obtained from 720,284 first return strokes lowering negative charge. The resulting distribution indicates that few negative strokes have peak currents exceeding 100 kA. Measurements have also been obtained of peak signal strength from 17,694 first return strokes lowering positive charge. These strokes have a median peak current of 45 kA, with some peak currents reaching 300-400 kA. The median peak signal strength and the peak current, double from summer to winter for both negative and positive first return strokes. The polarity of ground flashes is observed to be less than 5 percent positive throughout the summer and early fall, then increases to over 50 percent during the winter, and returns to less than 10 percent in early spring. The percent of positive flashes with one stroke is observed to be approximately 90 percent throughout the year. The percent of negative flashes with one stroke is observed to increase from 40 percent in the summer to approximately 80 percent in January, returning to less than 50 percent in the spring.

Orville, Richard E.↗