Search NASA⌕ Search

Engineering topics

Ovanesov, Mikhail V.

Publications and source records attributed to Ovanesov, Mikhail V..

Engineering and evaluation of FXa bypassing agents that restore hemostasis following Apixaban associated bleeding

Direct oral anticoagulants (DOACs) targeting activated factor Xa (FXa) are used to prevent or treat thromboembolic disorders. DOACs reversibly bind to FXa and inhibit its enzymatic activity. However, DOAC treatment carries the risk of anticoagulant-associated bleeding. Currently, only one specific agent, andexanet alfa, is approved to reverse the anticoagulant effects of FXa-targeting DOACs (FXaDOACs) and control life-threatening bleeding. However, because of its mechanism of action, andexanet alfa requires a cumbersome dosing schedule, and its use is associated with the risk of thrombosis. Here, we present the computational design, engineering, and evaluation of FXa-variants that exhibit anticoagulation reversal activity in the presence of FXaDOACs. Our designs demonstrate low DOAC binding affinity, retain FXa-enzymatic activity and reduce the DOAC-associated bleeding by restoring hemostasis in mice treated with apixaban. Importantly, the FXaDOACs reversal agents we designed, unlike andexanet alfa, do not inhibit TFPI, and consequently, may have a safer thrombogenic profile.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of wavelength and filter set choices on fluorogenic thrombin generation assay: Considerations for interlaboratory differences

Insufficient agreement between results of various in–house and commercial thrombin generation (TG) assays complicates TG adoption and use. can be caused by different assay variables, for example, volumes and concentrations of reagents. Although most modern assays employ the same fluorogenic thrombin substrate Z–Gly–Gly–Arg 7–amino–4–methylcoumarin (ZGGR–AMC), the excitation (Ex) and emission (Em) wavelengths used for fluorescence signal measurements can be different.

60 APPLIED LIFE SCIENCES↗

Comparative Analysis of Thrombin Calibration Algorithms and Correction for Thrombin-α2macroglobulin Activity

Background: The thrombin generation (TG) test is useful for characterizing global hemostasis potential, but fluorescence substrate artifacts, such as thrombin-α2macroglobulin (T-α2MG) signal, inner filter effect (IFE), substrate consumption, and calibration algorithms have been suggested as sources of intra- and inter-laboratory variance, which may limit its clinical utility. Methods: Effects of internal vs. external normalization, IFE and T-α2MG on TG curves in normal plasma supplemented with coagulation factors, thrombomodulin, and tissue factor were studied using the Calibrated Automated Thrombinography (CAT; Diagnostica Stago, Parsippany, NJ, USA) and in-house software. Results: The various calibration methods demonstrated no significant difference in producing TG curves, nor increased the robustness of the TG assay. Several TG parameters, including thrombin peak height (TPH), produced from internal linear calibration did not differ significantly from uncalibrated TG parameters. Further, TPH values from internal linear and nonlinear calibration with or without T-α2MG correction correlated well with TPH from external calibration. Higher coefficients of variation (CVs) for TPH values were observed in both platelet-free and platelet-rich plasma with added thrombomodulin. Conclusions: Our work suggests minimal differences between distinct computational approaches toward calibrating and correcting fluorescence signals into TG levels, with most samples returning similar or equivalent TPH results.

59 BASIC BIOLOGICAL SCIENCES↗