Search NASA⌕ Search

Engineering topics

Oyarzun, Diego I.

Publications and source records attributed to Oyarzun, Diego I..

Electrolyzer energy dominates separation costs in state-of-the-art CO 2 electrolyzers: Implications for single-pass CO 2 utilization

In low-temperature CO 2 electrolysis, a fundamental trade-off exists between maximizing electrolyzer performance and minimizing downstream CO 2 recovery. Here, by coupling a down-the-gas-channel electrolyzer model with a techno-economic analysis, we find that the optimal single-pass CO 2 conversion for ethylene production is typically low—on the order of 5%–10%—although larger optima are found if the H 2 faradic efficiency is very low. Similarly, strategies for eliminating carbonate crossover require more energy than downstream gas separation if they increase the cell potential by ~0.2 V; however, when CAPEX are accounted for, this “break-even” voltage increases to ~ 0.4 to 0.8 V for electricity prices varying from 6c/kWh to 1.5c/kWh. These findings are a consequence of the low energy requirements of industrial gas separation relative to electrochemical CO 2 reduction. Under most circumstances, maintaining near-optimal electrolyzer performance is more important than reducing or eliminating downstream gas separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-performance aqueous zinc-ion hybrid capacitors based on 3D printed metal-organic framework cathodes

The zinc-ion hybrid capacitor is a promising energy storage device, but current overall capacity is limited by the capacitance of the carbon cathode. We have produced a hierarchically porous, nitrogen-doped carbon cathode with good cycling and mechanical stability by 3D printing and pyrolysis of the zinc-based metal–organic framework ZIF-8. When incorporated into a zinc-ion hybrid capacitor, we achieved an areal capacitance of 16.9 F cm -2 and energy density of 7.23 mW h cm -2 , outperforming zinc-ion hybrid capacitors based on conventional cathodes.

25 ENERGY STORAGE↗

Unraveling the Ion Adsorption Kinetics in Microporous Carbon Electrodes: A Multiscale Quantum-Continuum Simulation and Experimental Approach

With the understanding that sorption in porous carbon electrodes is crucial to many environmental and energy technologies, such as capacitive deionization (CDI), supercapacitor energy storage, and activated carbon filters. In each of these examples, a practical model that can describe ion electrosorption kinetics is highly desirable for accelerating material design. Here, we proposed a multiscale model to study the ion electrosorption kinetics in porous carbon electrodes by combining quantum mechanical simulations with continuum approaches. Our model integrates the Butler-Volmer (BV) equation for sorption kinetics and a continuously stirred tank reactor (CSTR) formulation with atomistic calculations of ion hydration and ion-pore interactions based on density functional theory (DFT). We validated our model experimentally by using ion mixtures in a flow-through electrode CDI device and developed an in-line UV absorption system to provide unprecedented resolution of individual ions in the separation process. We showed that the multiscale model captures unexpected experimental phenomena that cannot be explained by the traditional ion electrosorption theory. The proposed multiscale framework provides a viable approach for modeling separation processes in systems where pore sizes and ion hydration effects strongly influence the sorption kinetics, which can be leveraged to explore possible strategies for improving carbon-based and, more broadly, pore-based technologies

36 MATERIALS SCIENCE↗

Selectivity of nitrate and chloride ions in microporous carbons: the role of anisotropic hydration and applied potentials

Understanding ion transport in porous carbons is critical for a wide range of technologies, including supercapacitors and capacitive deionization for water desalination, yet many details remain poorly understood. For instance, an atomistic understanding of how ion selectivity is influenced by the molecular shape of ions, morphology of the micropores and applied voltages is largely lacking. In this work, we combined molecular dynamics simulations with enhanced sampling methods to elucidate the mechanism of nitrate and chloride selectivity in subnanometer graphene slit-pores. We demonstrate that nitrate is preferentially adsorbed over chloride in the slit-like micropores. This preferential adsorption was found to stem from the weaker hydration energy and unique anisotropy of the ion solvation of nitrate. Beside the effects of ion dehydration, we found that applied potential plays an important role in determining the ion selectivity, leading to a lower selectivity of nitrate over chloride at a high applied potential. We conclude that the measured ion selectivity results from a complex interplay between voltage, confinement, and specific ion effects-including ion shape and local hydration structure.

36 MATERIALS SCIENCE↗

Cation Selectivity in Capacitive Deionization: Elucidating the Role of Pore Size, Electrode Potential, and Ion Dehydration

Capacitive deionization (CDI) is a promising water desalination technology that is applicable to the treatment of low-salinity brackish waters and the selective removal of ionic contaminants. In this work, we show that by making a small change in the synthetic procedure of hierarchical carbon aerogel monolith (HCAM) electrodes, we can adjust the pore-size distribution and tailor the selectivity, effectively switching between selective adsorption of calcium or sodium ions. Ion selectivity was measured for a mixture of 5 mM NaCl and 2.5 mM CaCl 2 . For the low activated flow-through CDI (fteCDI) cell, we observed extremely high sodium selectivity over calcium (S Na/Ca $\gg$ 10, no Ca 2+ adsorbed) at all of the applied potentials, while for the highly activated fteCDI cell, we observed a selectivity value of 6.6 ± 0.8 at 0.6 V for calcium over sodium that decreased to 2.2 ± 0.03 at 1.2 V. Molecular dynamics simulations indicated that the loss in Ca 2+ selectivity over Na+ at high applied voltages could be due to a competition between ion-pore electrostatic interactions and volume exclusion (“crowding”) effects. Interestingly, we also find with these simulations that the relative sizes of the ions change due to changes in hydration at a higher voltage.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Understanding resistances in capacitive deionization devices

The desalination characteristics of capacitive deionization (CDI) are significantly impacted by the cell resistance. Here we apply electrochemical impedance spectroscopy (EIS) to analyze the resistive properties of a CDI device, which include EIS measurements on a complete assembled cell (in two wire mode) and EIS measurements with additional contacts to decouple electrode/electrolyte and contact impedances (four wire mode). These measurements shed light on the interface between current collector and electrode as well as the internal capacitive and resistive elements of the cell. With two-wire and four-wire EIS measurements, we find that the often observed high-frequency arc(s) in the impedance spectra can be due to contact effects and/or an internal ionic-transfer resistance that is locally in parallel with macropore wall capacitance. In some cases, the two associated arcs in the Nyquist plot are overlapping and present simultaneously, making their identification in the EIS spectra difficult unless both two-wire and four-wire measurements are made. Despite causing a large high-frequency arc in the Nyquist plot, we find that the apparent internal ionic-transfer resistance is negligible compared to the resistances of the electrode, separator, and external electronic components. Here, an investigation of the contact impedance between the electrode and current collector reveals a parallel RC arc that can grow over time if an improper material is used (e.g., titanium). In our system, the electrode ionic resistance dominates the total Ohmic power dissipation, which has implications for scale-up of CDI systems and future improvements of cell design.

36 MATERIALS SCIENCE↗

On the competition between mixing rate and uniformity in a coaxial hydrodynamic focusing mixer

Fast microfluidic mixers for use with line-of-sight integrating detection schemes pose unique challenges. Such detectors typically cannot discriminate signal from slow moving (e.g. near internal walls) and fast-moving portions of the fluid stream. This convolves reaction rate dynamics with fluid flow residence time dynamics. Further, the small cross sections of typical three-dimensional hydrodynamic focusing devices lead to lower detection signals. The current study focuses on achieving both small time scales of mixing and homogenous residence times. This is achieved by injecting sample through a center capillary and hydrodynamically focusing using a sheath flow within a tapered second capillary. The current design also features a third, larger coaxial capillary. The mixed stream flows into the large cross-section of this third capillary to decelerate and expand the stream by up to 14-fold to improve line-of-sight signal strength of reaction products. Hydrodynamic focusing, mixing, and expansion are studied using analytical and numerical models and also studied experimentally using a fluorescein-iodide quenching reaction. The experimentally validated models are used to explore trade-offs between mixing rate and uniformity. For the first time, this work presents detailed analysis of the Lagrangian time history of species transport during mixing inside coaxial capillaries to measure mixing nonuniformity. The mixing region enables order 100 μs mixing times and residence time widths of the same order (140 μs).

42 ENGINEERING↗