Search NASA⌕ Search

Engineering topics

Oye, V.

Publications and source records attributed to Oye, V..

Identifying geological structures through microseismic cluster and burst analyses complementing active seismic interpretation

At the Decatur carbon capture and storage site (IL, USA) CO 2 has been injected from 2011–2014 and from 2017 to present near the base of the Lower Mt. Simon Sandstone saline reservoir, resulting in microseismicity. Microseismicity is mainly located in the basement and distributed in distinct spatial clusters. The lack of significant impedance contrasts within the basement makes the interpretation of active-source seismic reflection data challenging, however, recent reprocessing allowed to resolve faults above and at the top of the basement. These faults generally do not coincide with the location of microseismic events and their continuation to the general depth of the seismic events cannot be assumed. This paper shows how the interpretation of the microseismicity can complement structural interpretations of active-source seismic reflection data. In particular, we analyze clusters and bursts (abrupt increases) of microseismicity, identify unresolved, smaller-scale weaknesses and extract statistical parameters. These parameters allow comparisons with the interpreted faults, and with fracture sets intercepted by boreholes. During injection at the Decatur site, the injection pressure was kept far below fracture pressure, nevertheless, seismic events were induced and spread far beyond the expected extent of the CO 2 plume. We argue that local stress transfers related to the CO 2 injection reactivated pre-existing fractures within the critically stressed basement. Finally, we conducted a slip tendency analysis for faults interpreted from active seismic, selected cluster, bursts and nodal planes from focal mechanisms to determine if the interpreted structures are optimally oriented with respect to the stress regime. Our results suggest that the orientation of fractures close to the injection well, generally shows slight deviations from the optimal orientation for slip. This might indicate either slight local deviations of the maximum horizontal stress azimuth from the average direction used in the analysis, or the lack of optimally oriented fractures at this location.

58 GEOSCIENCES↗

Relocating microseismicity from downhole monitoring of the Decatur CCS site using a modified double-difference algorithm

SUMMARY The injection of CO2 at the Decatur carbon capture and storage site has generated significant microseismic activity, which occurs in distinct spatial clusters up to approximately 2.2 km from the primary injection well. Accurate and precise event locations are vital for the characterization of the microseismicity to help understand the reservoir response to the CO2 injection, whilst enabling the identification of minor faults and fractures below the resolution of conventional active seismic imaging. However, microseismic monitoring of fluid injection sites, such as Decatur, is often performed using a network of borehole sensors often from a single well. While these downhole sensors have excellent detection capabilities, their poor azimuthal coverage limits the ability to precisely determine event locations. We have developed a modified double-difference relocation algorithm suitable for both 1-D and 3-D velocity models, and which incorporates differential back azimuth observations to allow the benefits of the original double-difference algorithm to be applicable to a downhole microseismic monitoring setting. Applying the modified double-difference algorithm to the microseismicity at Decatur, we have successfully relocated 4293 events. The relocation included over 59 million observations for 757 285 event pairs, split across seven geographic regions. Despite the majority of observations being recorded in only two boreholes, with an almost identical azimuthal coverage, the results have shown to be reliable with significantly reduced residuals and low uncertainties associated with the final locations. We have analysed the residuals in terms of their association with each geographic region, data type, station and individual events, to fully appreciate their influence in the inversion and the fit of the data to the final set of event locations. For each region, the relocated seismicity has become less diffuse with improved clustering, and with newly visible linear features often orientated in a NE–SW direction. These results show the potential improvements that can be made to microseismic event locations recorded by a borehole network with a limited and variable azimuthal distribution.

58 GEOSCIENCES↗

Characterization of induced seismicity patterns derived from internal structure in event clusters

Microseismicity induced by CO 2 injection at Decatur, Illinois, occurs in distinct clusters and shows no obvious correlation with the proceeding pressure front. Here, we analyze some of these clusters in more depth by using a waveform cross-correlation approach. With this approach we can associate about 1400 events from two clusters, with moment magnitudes between 1.1 and -1.7, with specific formations of much smaller vertical dimensions (tens of meters) than the depth resolution of traveltime-based event locations. The differentiation of reservoir and basement events, and the definition of subclusters by waveform correlation, rather than by location, helps to better analyze the spatiotemporal evolution of the events within a cluster. In the Decatur case, this is characterized by event migration from the reservoir into the adjacent basement. The spatial variation of Brune stress drop and Gutenberg b value exhibits signs of a fluid-driven triggering mechanism at the cluster level, revealing a punctual hydraulic connection between reservoir and basement, most likely associated with basement faults cutting into the reservoir. The observed clustering of microseismicity can thus be explained by the lateral heterogeneity of permeability and crustal strength and is overall consistent with a pressure-induced triggering mechanism. Hence, proper long-term risk mitigation for large-scale fluid injection close to the basement requires prior mapping of small subseismic basement-connected faults.

58 GEOSCIENCES↗