Search NASA⌕ Search

Engineering topics

Pablant, N. A.

Publications and source records attributed to Pablant, N. A..

At least 19 records

Full-torus impurity transport simulation in boron powder injection experiments in the Large Helical Device

The toroidal distribution of boron deposition on plasma-facing components (PFCs) in boron powder injection using an impurity power dropper (IPD) was investigated by full-torus simulation and observations in a systematic plasma density-scan experiment. The images of the ablation of dropped boron powders observed with a visible CCD camera were consistently explained by the simulations of the ablation positions of the boron powders considering the size distribution. Simulations assuming full-torus boron deposition on the PFCs did not reproduce the observed intensity profile of boron emission lines for higher plasma densities. It indicated that the density of boron deposited on PFCs installed toroidally far from the IPD was low for higher plasma densities due to the change in the ablation positions of the boron powders toward the outboard side. The experimental results verified the previous full-torus simulation of the toroidal distribution of the boron deposition in both lower and higher plasma densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Versatile multi-energy hard x-ray camera to study confined and unconfined fast electron dynamics and anisotropies (Invited)

A powerful and flexible hard x-ray (HXR) camera has been recently installed and tested on the WEST tokamak (CEA, France) in collaboration with the Princeton Plasma Physics Laboratory. The diagnostic is a pinhole camera fielded with a 2D pixel detector equipped with a 1 mm thick CdTe sensor. The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at the pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space, energy, and time resolved x-ray measurements. The novel camera has been used to measure the core radiation from non-Maxwellian (fast) electrons accelerated by Lower Hybrid (LH) waves and also the beam–target emission of tungsten in the divertor region produced by fast electron losses interacting with the target. In addition, anisotropic hard x-ray emission has been detected for the first time at the WEST core and edge plasma, with opposite toroidal intensity trends. Finally, experimental vertical and toroidal HXR profiles have been successfully reproduced with the LH code LUKE.

47 OTHER INSTRUMENTATION↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

The Updated Case for a National Stellarator Program

The stellarator concept provides a compelling path to a Fusion Pilot Plant that features steady state, disruption free operation with low recirculating power. The need for a national stellarator program and a new stellarator experiment have been highlighted previously in the FESAC Long-Range Plan (LRP) and the APS Community Planning Process (CPP). There have been many advances in the stellarator field since those reports were drafted, both theoretically and experimentally, that provide an even stronger motivation for an expanded stellarator program within the US. In addition, in recent years a number of private companies have been founded (and funded) to pursue the stellarator concept, two of which are FES Milestone Program award recipients. An expanded stellarator program is needed to fully support these companies and their goals. This whitepaper aims to briefly provide an updated outlook on the need for a national stellator program including benefits to private industry and opportunities for Public Private Partnerships (PPP).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Compelling Need for a Mid-Scale Stellarator Facility

In the pursuit of the goal of commercial fusion as an abundant and safe source of energy, the stellarator is a leading concept with compelling attractiveness and demonstrated performance. In this white paper we, as a community of US researchers from Universities, National Laboratories, and Private Industry, involved in studying the stellarator concept, lay out the programmatic and technical motivation for a new mid-size stellarator research facility in the US. This contribution is complementary to several other whitepapers authored by members of our community which address different mid-scale stellarator aspects. A community based technical facility proposal has been prepared by F. Parra, et al: Flexible Stellarator Physics Facility. Two private stellarator companies have submitted proposals supporting the development of a mid-scale stellarator: Thea Energy (C.P.S. Swanson, et al.), Type One Energy (W. Guttenfelder, et al.).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Achieving stationary high performance plasmas at Wendelstein 7-X

This work reports on recent results on the search for high performance plasma scenarios at the magnetically confined stellarator fusion device Wendelstein 7-X. In four new designed scenarios, the development from transient toward stationary plasmas of improved performance has been realized. In particular, a high performance duration of up to 5 s, an energy confinement time of 0.3 s, a diamagnetic energy of 1.1 MJ, a central ion temperature of 2.2 keV, and a fusion triple product of 3.4 x 10 19 m -3 ∙ keV ∙ s have been achieved, and previously observed limitations of the machine have been overcome, regarding both the performance and its duration. The two main experimental techniques for stationary high performance are neutral beam injection core fueling on the one hand and the use of a magnetic field configuration with internal islands on the other hand. Two of the developed scenarios are expected to be extendable straightforward toward a duration of several tens of seconds, making use of the long pulse operation capabilities of W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Spatial calibration and synthetic diagnostic of a multi-energy hard x-ray camera at WEST tokamak

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam–target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

Impurity transport in ion- and electron-root confinement scenarios at Wendelstein 7-X

This paper reports on the observation of enhanced Ar impurity confinement in high density, turbulence reduced ion-root confinement (IRC) scenarios in Wendelstein 7-X (W7-X). Compared to the central electron-root confinement (CERC), Ar densities are substantially increased up to one order of magnitude and Ar flux profiles switch from slightly positive to pronounced negative fluxes all along the plasma radius in IRC. Estimations of the diffusive D and convective V transport parameter profiles using the STRAHL impurity transport code suggest a fundamentally different behavior in CERC and IRC with, compared to neoclassical values, high diffusive D and typical V profiles in CERC versus strongly reduced D and pronounced negative V profiles in IRC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

Demonstration of reduced neoclassical energy transport in Wendelstein 7-X

Research on magnetic confinement of high-temperature plasmas has the ultimate goal of harnessing nuclear fusion for the production of electricity. Although the tokamak is the leading toroidal magnetic-confinement concept, it is not without shortcomings and the fusion community has therefore also pursued alternative concepts such as the stellarator. Unlike axisymmetric tokamaks, stellarators possess a three-dimensional (3D) magnetic field geometry. The availability of this additional dimension opens up an extensive configuration space for computational optimization of both the field geometry itself and the current-carrying coils that produce it. Such an optimization was undertaken in designing Wendelstein 7-X (W7-X), a large helical-axis advanced stellarator (HELIAS), which began operation in 2015 at Greifswald, Germany. A major drawback of 3D magnetic field geometry, however, is that it introduces a strong temperature dependence into the stellarator’s non-turbulent ‘neoclassical’ energy transport. Indeed, such energy losses will become prohibitive in high-temperature reactor plasmas unless a strong reduction of the geometrical factor associated with this transport can be achieved; such a reduction was therefore a principal goal of the design of W7-X. In spite of the modest heating power currently available, W7-X has already been able to achieve high-temperature plasma conditions during its 2017 and 2018 experimental campaigns, producing record values of the fusion triple product for such stellarator plasmas. The triple product of plasma density, ion temperature and energy confinement time is used in fusion research as a figure of merit, as it must attain a certain threshold value before net-energy-producing operation of a reactor becomes possible. Here we demonstrate that such record values provide evidence for reduced neoclassical energy transport in W7-X, as the plasma profiles that produced these results could not have been obtained in stellarators lacking a comparably high level of neoclassical optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of injection and confinement improvement through impurity induced profile modifications on the Wendelstein 7-X stellarator

Pulsed injections of boron carbide granules into Wendelstein 7-X stellarator (W7-X) plasmas transiently increase the plasma stored energy and core ion temperatures above the reference W7-X experimental programs by up to 30%. In a series of 4 MW electron cyclotron resonance heating experiments, the PPPL Probe Mounted Powder Injector provided 50 ms bursts of 100 μm granules every 350 ms at estimated quantities ranging from approximately 1 mg/pulse to over 30 mg/pulse. For each injection, the stored energy was observed to initially drop and the radiated power transiently increased, while the radial electron density profile rose at the edge as material was assimilated. Once the injected boron carbide was fully absorbed, the density rise transitioned to the core while the stored energy increased above the previous baseline level by an amount linearly correlated with the injection quantity. During the injection, the ion temperature gradient steepened with peak core ion temperatures observed to increase from a nominal 1.7 keV to over 2.6 keV for the largest injection amounts. Enhanced performance is accompanied by a reversal of the radial electric field at ρ < 0.3, indicating that the core transport has switched to the ion root. These observations are suggestive of a change in transport and provide further evidence that externally induced profile modifications provide a possible path to enhanced W7-X performance metrics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Charge-state independent anomalous transport for a wide range of different impurity species observed at Wendelstein 7-X

Here, the plasma volume averaged impurity confinement of selected charge states and impurity species has been characterized for the Stellarator Wendelstein 7-X (W7-X), covering a wide range of atomic charges (Z = 12–44) and atomic masses (M = 28–184). A comparison of the experimental findings to theoretical neoclassical and turbulent transport expectations suggests, aside from/in addition to the neoclassical transport, an additional significant anomalous transport mechanism, which is not inconsistent with the predictions of a turbulence dominated impurity transport and is in agreement with the experimental results from recent transport studies based on the direct measurements of impurity diffusion profiles, performed at W7-X.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced energy confinement after series of pellets in Wendelstein 7-X

A series of ice pellets was injected into the advanced stellarator Wendelstein 7-X (W7-X). Although the pellets were small and slow, deep and efficient particle fueling could be observed experimentally. The most striking feature appearing after the injection of the pellets, however, was a transient increase in the energy confinement time. This transient phase resembled in several aspects modes of enhanced confinement after gas-puff or pellet injection, as observed in other fusion experiments. All experimental attempts, to prolong this phase, failed. In this paper, discharges are described that show the enhanced energy confinement, and some conditions are summarized which seem to be essential in order to generate it. The focus here is on deep particle fueling by pellets, and shaping of the density profiles during and after the series of pellets. During this time, neutral gas particle re-fueling at the plasma edge is reduced, while density profile peaking and low impurity radiation losses are present.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Increasing the density in Wendelstein 7-X: benefits and limitations

In stellarators, increasing the density is beneficial for the energy confinement. While there is no single reason for this observation, it is still very robust across different devices and this is reflected in the empirical energy confinement time scaling for stellarators, ISS04. In order to study whether this is also true for Wendelstein 7-X, here the density scaling of the energy confinement time is analyzed and compared to ISS04 for the first divertor experiments. When the density is increased beyond a critical density, however, radiative collapses are frequently observed. Existing analytical models for the critical density are revisited to assess whether they can predict the accessible density range. Furthermore, since close to the collapse the radiation losses increase substantially, the impact on the global energy confinement is investigated. It is found that in plasmas with high radiation the density scaling of the energy confinement time becomes weaker, the reason for this observation is not yet clear. In the second half of the first divertor campaign, boronization was applied to W7-X for the first time. This broadened the operational window, allowing for operation at higher density and, hence, higher stored energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge exchange recombination spectroscopy at Wendelstein 7-X

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, to include typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

47 OTHER INSTRUMENTATION↗