Search NASA⌕ Search

Engineering topics

Pacheco, Jose L.

Publications and source records attributed to Pacheco, Jose L..

A performant energy-conserving particle reweighting method for Particle-in-Cell simulations

A new particle-based reweighting method is developed and demonstrated in the Aleph Particle-in-Cell with Direct Simulation Monte Carlo (PIC-DSMC) program. Novel splitting and merging algorithms ensure that modified particles maintain physically consistent positions and velocities. This method allows a single reweighting simulation to efficiently model plasma evolution over orders of magnitude variation in density, while accurately preserving energy distribution functions (EDFs). Demonstrations on electrostatic sheath and collisional rate dynamics show that reweighting simulations achieve accuracy comparable to fixed weight simulations with substantial computational time savings. This highly performant reweighting method is recommended for modeling plasma applications that require accurate resolution of EDFs or exhibit significant density variations in time or space.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tunnel ionization within a one-dimensional, undriven plasma sheath

In high density, high temperature plasmas, the plasma sheath that develops can result in extremely high electric fields, on the order of tens to hundreds of V/nm. Under the right conditions, these electric fields can reach magnitudes that can increase the probability of electron tunneling ionization to occur, resulting in one or more electron-ion pairs. The presence of tunneling ionization can then modify the development of the plasma sheath, as well as properties such as the ion and electron densities and plasma potential. The tunnel ionization process for hydrogen atoms is demonstrated, in this work, as implemented in a Sandia National Laboratories, particle-in-cell code Aleph. Results are presented for the application of the tunnel ionization process to a one-dimensional, undriven plasma sheath. Additional results for cases that consider warm ions and neutrals, the inclusion of electron–neutral collisions, and the injection of neutral particles, as well as the application to various plasma devices, will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation

The freely available “Stopping and Range of Ions in Matter” (SRIM) code is used for evaluating ion beam ranges and depth profiles. We present secondary ion mass spectrometry and Rutherford backscattering experimental results of Si samples implanted with low energy Sb ions to evaluate the accuracy of SRIM simulations. We show that the SRIM simulation systematically overestimates the range by 2–6 nm and this overestimation increases for larger ion implantation energy. For the lowest energy implantation investigated, here we find up to a 25% error between the SRIM simulation and the measured range. Finally, the ion straggle shows excellent agreement between simulation and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lithium source for focused ion beam implantation and analysis

In this work, we present a new Li source for focused ion beam applications. Based on an AuSi eutectic alloy, Li is added as an impurity to minimize effects from degradation when exposed to air. We show the source is stable over the course of an hour and spot sizes ≲10 nm can be achieved. The Li beam can achieve hundreds of nanometer ranges in semiconductors with minimal damage being generated along the path length. The source performance is evaluated through a high-resolution ion beam induced charge collection experiment on an Si-based detector. Further application of the source for ion beam analysis is numerically explored; the example investigated is based on probing a semiconductor heterostructure through a Rutherford backscattering experiment, where the Li beam can reveal information that is inaccessible with either low energy or high energy He projectiles used as probes.

36 MATERIALS SCIENCE↗

Modeling a ring magnet in ALEGRA

We show here that Sandia's ALEGRA software can be used to model a permanent magnet in 2D and 3D, with accuracy matching that of the open-source commercial software FEMM. This is done by conducting simulations and experimental measurements for a commercial-grade N42 neodymium alloy ring magnet with a measured magnetic field strength of approximately 0.4 T in its immediate vicinity. Transient simulations using ALEGRA and static simulations using FEMM are conducted. Comparisons are made between simulations and measurements, and amongst the simulations, for sample locations in the steady-state magnetic field. The comparisons show that all models capture the data to within 7%. The FEMM and ALEGRA results agree to within approximately 2%. The most accurate solutions in ALEGRA are obtained using quadrilateral or hexahedral elements. In the case where iron shielding disks are included in the magnetized space, ALEGRA simulations are considerably more expensive because of the increased magnetic diffusion time, but FEMM and ALEGRA results are still in agreement. The magnetic field data are portable to other software interfaces using the Exodus file format.

36 MATERIALS SCIENCE↗

A Novel use of Direct Simulation Monte-Carlo to Model Dynamics of COVID-19 Pandemic Spread

In this report, we evaluate a novel method for modeling the spread of COVID-19 pandemic. In this new approach we leverage methods and algorithms developed for fully-kinetic plasma physics simulations using Particle-In-Cell (PIC) Direct Simulation Monte-Carlo (DSMC) models. This approach then leverages Sandia-unique simulation capabilities, and High-Performance Computer (HPC) resources and expertise in particle-particle interactions using stochastic processes. Our hypothesis is that this approach would provide a more efficient platform with assumptions based on physical data that would then enable the user to assess the impact of mitigation strategies and forecast different phases of infection. This work addresses key scientific questions related to the assumptions this new approach must make to model the interactions of people using algorithms typically used for modeling particle interactions in physics codes (kinetic plasma, gas dynamics). The model developed uses rational/physical inputs while also providing critical insight; the results could serve as inputs to, or alternatives for, existing models. The model work presented was developed over a four-week time frame, thus far showing promising results and many ways in which this model/approach could be improved. This work is aimed at providing a proof-of-concept for this new pandemic modeling approach, which could have an immediate impact on the COVID-19 pandemic modeling, while laying a basis to model future pandemic scenarios in a manner that is timely and efficient. Additionally, this new approach provides new visualization tools to help epidemiologists comprehend and articulate the spread of this and other pandemics as well as a more general tool to determine key parameters needed in order to better predict pandemic modeling in the future. In the report we describe our model for pandemic modeling, apply this model to COVID-19 data for New York City (NYC), assess model sensitivities to different inputs and parameters and , finally, propagate the model forward under different conditions to assess the effects of mitigation and associated timing. Finally, our approach will help understand the role of asymptomatic cases, and could be extended to elucidate the role of recovered individuals in the second round of the infection, which is currently being ignored.

59 BASIC BIOLOGICAL SCIENCES↗

COVID-19 LDRD Project Summaries

Sandia National Laboratories currently has 27 COVID-related Laboratory Directed Research & Development (LDRD) projects focused on helping the nation during the pandemic. These LDRD projects cross many disciplines including bioscience, computing & information sciences, engineering science, materials science, nanodevices & microsystems, and radiation effects & high energy density science.

36 MATERIALS SCIENCE↗

Electroforming-Free TaOx Memristors using Focused Ion Beam Irradiations

In this study, we demonstrate creation of electroforming-free TaOx memristive devices using focused ion beam irradiations to locally define conductive filaments in TaOx films. Electrical characterization shows that these irradiations directly create fully functional memristors without the need for electroforming. Finally, ion beam forming of conductive filaments combined with state-of-the-art nano-patterning presents a CMOS compatible approach to wafer level fabrication of fully formed and operational memristors.

36 MATERIALS SCIENCE↗

Strain engineering of the silicon-vacancy center in diamond

We control the electronic structure of the silicon-vacancy (SiV) color-center in diamond by changing its static strain environment with a nano-electro-mechanical system. This allows deterministic and local tuning of SiV optical and spin transition frequencies over a wide range, an essential step towards multiqubit networks. In the process, we infer the strain Hamiltonian of the SiV revealing large strain susceptibilities of order 1 PHz/strain for the electronic orbital states. Here, we identify regimes where the spin-orbit interaction results in a large strain susceptibility of order 100 THz/strain for spin transitions, and propose an experiment where the SiV spin is strongly coupled to a nanomechanical resonator.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Controlling the coherence of a diamond spin qubit through its strain environment

The uncontrolled interaction of a quantum system with its environment is detrimental for quantum coherence. For quantum bits in the solid state, decoherence from thermal vibrations of the surrounding lattice can typically only be suppressed by lowering the temperature of operation. Here, we use a nano-electro-mechanical system to mitigate the effect of thermal phonons on a spin qubit – the silicon-vacancy colour centre in diamond – without changing the system temperature. By controlling the strain environment of the colour centre, we tune its electronic levels to probe, control, and eventually suppress the interaction of its spin with the thermal bath. Strain control provides both large tunability of the optical transitions and significantly improved spin coherence. Finally, our findings indicate the possibility to achieve strong coupling between the silicon-vacancy spin and single phonons, which can lead to the realisation of phonon-mediated quantum gates and nonlinear quantum phononics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fiber-Coupled Diamond Quantum Nanophotonic Interface

Color centers in diamond provide a promising platform for quantum optics in the solid state, with coherent optical transitions and long-lived electron and nuclear spins. Building upon recent demonstrations of nanophotonic waveguides and optical cavities in single-crystal diamond, we now demonstrate on-chip diamond nanophotonics with a high-efficiency fiber-optical interface achieving > 90 % power coupling at visible wavelengths. Here, we use this approach to demonstrate a bright source of narrow-band single photons based on a silicon-vacancy color center embedded within a waveguide-coupled diamond photonic crystal cavity. Our fiber-coupled diamond quantum nanophotonic interface results in a high flux (approximately 38 kHz) of coherent single photons (near Fourier limited at < 1 - GHz bandwidth) into a single-mode fiber, enabling possibilities for realizing quantum networks that interface multiple emitters, both on chip and separated by long distances.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scalable focused ion beam creation of nearly lifetime-limited single quantum emitters in diamond nanostructures

The controlled creation of defect centre—nanocavity systems is one of the outstanding challenges for efficiently interfacing spin quantum memories with photons for photon-based entanglement operations in a quantum network. Here we demonstrate direct, maskless creation of atom-like single silicon vacancy (SiV) centres in diamond nanostructures via focused ion beam implantation with ~32 nm lateral precision and <50 nm positioning accuracy relative to a nanocavity. We determine the Si+ ion to SiV centre conversion yield to be ~2.5% and observe a 10-fold conversion yield increase by additional electron irradiation. Low-temperature spectroscopy reveals inhomogeneously broadened ensemble emission linewidths of ~51 GHz and close to lifetime-limited single-emitter transition linewidths down to 126±13 MHz corresponding to ~1.4 times the natural linewidth. Furthermore, this method for the targeted generation of nearly transform-limited quantum emitters should facilitate the development of scalable solid-state quantum information processors.

36 MATERIALS SCIENCE↗

Fabrication and characterization of a co-planar detector in diamond for low energy single ion implantation

We demonstrate low energy single ion detection using a co-planar detector fabricated on a diamond substrate and characterized by ion beam induced charge collection. Histograms are taken with low fluence ion pulses illustrating quantized ion detection down to a single ion with a signal-to-noise ratio of approximately 10. We anticipate that this detection technique can serve as a basis to optimize the yield of single color centers in diamond. In conclusion, the ability to count ions into a diamond substrate is expected to reduce the uncertainty in the yield of color center formation by removing Poisson statistics from the implantation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-micron resolution of localized ion beam induced charge reduction in silicon detectors damaged by heavy ions

In this study, displacement damage reduces ion beam induced charge (IBIC) through Shockley-Read-Hall recombination. Closely spaced pulses of 200 keV Si ++ ions focused in a 40 nm beam spot are used to create damage cascades within 0.25 μm 2 areas. Damaged areas are detected through contrast in IBIC signals generated with focused ion beams of 200 keV Si ++ ions and 60 keV Li + ions. IBIC signal reduction can be resolved over sub-micron regions of a silicon detector damaged by as few as 1000 heavy ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon Quantum Dots with Counted Antimony Donor Implants

Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.

Singh, Meenakshi↗

An overview of the facilities, activities, and developments at the University of North Texas Ion Beam Modification and Analysis Laboratory (IBMAL)

The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.

43 PARTICLE ACCELERATORS↗

Investigation of beam transmission in A 9SDH-2 3.0 MV NEC pelletron tandem accelerator

Electrostatic tandem accelerators are widely used to accelerate ions for experiments in materials science such as high energy ion implantation, materials modification, and analyses. Many applications require high beam current as well as high beam brightness at the target; thus, maximizing the beam transmission through such electrostatic accelerators becomes important. The Ion Beam Modification and Analysis Laboratory (IBMAL) at University of North Texas is equipped with four accelerators, one of which is a 9SDH-2 3.0 MV National Electrostatic Corporation (NEC) Pelletron Registered-Sign tandem accelerator. The tandem accelerator is equipped with three ion sources: one radio frequency-He ion source (Alphatross) and two ion sources of Cs-sputter type, the SNICS II (Source of Negative Ions by Cesium Sputtering) and a Cs-sputter source for trace-element accelerator based mass spectrometry. This work presents a detailed study of the beam transmission of hydrogen, silicon, and silver ions through the accelerator using the SNICS ion source with injection energies ranging from 20 keV to 70 keV. The beam transmission is quantified for three different terminal voltages: 1.5 MV, 2.0 MV and 2.5 MV. For a given terminal voltage, it has been found that beam transmission is strongly dependent on the ion source injector potential. Details of experiments and data analysis are presented.

43 PARTICLE ACCELERATORS↗