Search NASA⌕ Search

Engineering topics

Packman, P. F.

Publications and source records attributed to Packman, P. F..

The application of a time-domain deconvolution technique for identification of experimental acoustic-emission signals

A method is presented for the signature analysis of pulses by reconstructing in the time domain the shape of the pulse prior to its passing through the measurement system. This deconvolution technique is first evaluated using an idealized system and analytical pulse models and is shown to provide improved results. An experimental situation is then treated; system-component models are developed for the digitizer, tape recorder, filter, transducer and mechanical structure. To accommodate both calibration results and manufacturer's data, and to provide stable mathematical models entails considerable effort: some 30 parameters must be identified to model this system - which is still a substantial approximation - albeit of very high order. Experimental pulses generated by a ball drop, spark discharge and a tearing crack are then deconvoluted 'back through' the system as modeled, using this technique. These results are compared and indicate (a) that consistent shapes may be expected from a given type of source and (b) that some sources can be identified with greater clarity using the deconvolution approach.

Houghton, J. R.↗

Pulse analysis of acoustic emission signals

A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio were examined in the frequency domain analysis and pulse shape deconvolution was developed for use in the time domain analysis. Comparisons of the relative performance of each analysis technique are made for the characterization of acoustic emission pulses recorded by a measuring system. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameter values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emission associated with (a) crack propagation, (b) ball dropping on a plate, (c) spark discharge, and (d) defective and good ball bearings. Deconvolution of the first few micro-seconds of the pulse train is shown to be the region in which the significant signatures of the acoustic emission event are to be found.

Houghton, J. R.↗

On the improvement of deconvolution with digitized data using a Runge-Kutta integration scheme

A relatively simple change in the treatment of the input function in numerical integration of high-order differential equations by Runge-Kutta methods provides substantial improvements in accuracy, particularly when the forcing function is in digitized form. The Runge-Kutta-Gill coefficients are modified to incorporate the changes; with pulse-type excitations, improvements on the order of 2 to 50 times greater accuracy are demonstrated.

Houghton, J. R.↗

Optimal design and evaluation criteria for acoustic emission pulse signature analysis

Successful pulse recording and evaluation is strongly dependent on the instrumentation system selected and the method of analyzing the pulse signature. The paper studies system design, signal analysis techniques, and interdependences with a view toward defining optimal approaches to pulse signal analysis. For this purpose, the instrumentation system is modeled, and analytical pulses, representative of the types of acoustic emissions to be distinguished are passed through the system. Particular attention is given to comparing frequency spectrum analysis and deconvolution referred to as time domain reconstruction of the pulse or pulse train. The possibility of optimal transducer-filter system parameters is investigated. Deconvolution of a pulse is shown to be a superior approach for transient pulse analysis. Reshaping of a transducer output back to the original input pulse is possible and gives an accurate representation of the generating pulse in the time domain. Any definable transducer and filter system can be used for measurement of pulses by means of the deconvolution method. Selection of design variables for general usage is discussed.

Houghton, J. R.↗

Pulse analysis of acoustic emission signals

A method for the signature analysis of pulses in the frequency domain and the time domain is presented. Fourier spectrum, Fourier transfer function, shock spectrum and shock spectrum ratio were examined in the frequency domain analysis, and pulse shape deconvolution was developed for use in the time domain analysis. Comparisons of the relative performance of each analysis technique are made for the characterization of acoustic emission pulses recorded by a measuring system. To demonstrate the relative sensitivity of each of the methods to small changes in the pulse shape, signatures of computer modeled systems with analytical pulses are presented. Optimization techniques are developed and used to indicate the best design parameters values for deconvolution of the pulse shape. Several experiments are presented that test the pulse signature analysis methods on different acoustic emission sources. These include acoustic emissions associated with: (1) crack propagation, (2) ball dropping on a plate, (3) spark discharge and (4) defective and good ball bearings. Deconvolution of the first few micro-seconds of the pulse train are shown to be the region in which the significant signatures of the acoustic emission event are to be found.

Houghton, J. R.↗

Assessment of NDE Reliability Data

Twenty sets of relevant Nondestructive Evaluation (NDE) reliability data have been identified, collected, compiled, and categorized. A criterion for the selection of data for statistical analysis considerations has been formulated. A model to grade the quality and validity of the data sets has been developed. Data input formats, which record the pertinent parameters of the defect/specimen and inspection procedures, have been formulated for each NDE method. A comprehensive computer program has been written to calculate the probability of flaw detection at several confidence levels by the binomial distribution. This program also selects the desired data sets for pooling and tests the statistical pooling criteria before calculating the composite detection reliability. Probability of detection curves at 95 and 50 percent confidence levels have been plotted for individual sets of relevant data as well as for several sets of merged data with common sets of NDE parameters.

Yee, B. G. W.↗