Hot gas ingestion: From model results to full scale engine testing

An overview is presented of a joint NASA Lewis McDonnell Aircraft Co. Hot Gas Ingestion (HGI) test program in NASA Lewis' 9 x 15 foot Low Speed Wind Tunnel (LSWT). Advanced short takeoff vertical landing (ASTOVL) aircraft capable of operating from remote sites, damaged runways, aircraft carriers and small air-capable ships are being pursued for deployment around the turn of the century. To achieve this goal, it is important that technologies critical to this unique class of aircraft be developed. One of the ASTOVL concepts, the vectored thrust, has as its critical technology item, the potential of hot gas ingestion (which occurs during vertical flight operation while in ground effect) as a key development issue. Recognizing this need, NASA Lewis Powered Lift Section and McAir have defined a cooperative program for testing in the Lewis 9 x 15 foot LSWT. This program is described in detail.

Johns, Albert L.

Cooling system for high speed aircraft

The system eliminates the necessity of shielding an aircraft airframe constructed of material such as aluminum. Cooling is accomplished by passing a coolant through the aircraft airframe, the coolant acting as a carrier to remove heat from the airframe. The coolant is circulated through a heat pump and a heat exchanger which together extract essentially all of the added heat from the coolant. The heat is transferred to the aircraft fuel system via the heat exchanger and the heat pump. The heat extracted from the coolant is utilized to power the heat pump. The heat pump has associated therewith power turbine mechanism which is also driven by the extracted heat. The power turbines are utilized to drive various aircraft subsystems, the compressor of the heat pump, and provide engine cooling.

Lawing, P. L.

High heat flux actively cooled honeycomb sandwich structural panel for a hypersonic aircraft

The results of a program to design and fabricate an unshielded actively cooled structural panel for a hypersonic aircraft are presented. The design is an all-aluminum honeycomb sandwich with embedded cooling passages soldered to the inside of the outer moldline skin. The overall finding is that an actively cooled structure appears feasible for application on a hypersonic aircraft, but the fabrication process is complex and some material and manufacturing technology developments are required. Results from the program are summarized and supporting details are presented.

Koch, L. C.

Design and fabrication of a radiative actively cooled honeycomb sandwich structural panel for a hypersonic aircraft

The panel assembly consisted of an external thermal protection system (metallic heat shields and insulation blankets) and an aluminum honeycomb structure. The structure was cooled to temperature 442K (300 F) by circulating a 60/40 mass solution of ethylene glycol and water through dee shaped coolant tubes nested in the honeycomb and adhesively bonded to the outer skin. Rene'41 heat shields were designed to sustain 5000 cycles of a uniform pressure of + or - 6.89kPa (+ or - 1.0 psi) and aerodynamic heating conditions equivalent to 136 kW sq m (12 Btu sq ft sec) to a 422K (300 F) surface temperature. High temperature flexible insulation blankets were encased in stainless steel foil to protect them from moisture and other potential contaminates. The aluminum actively cooled honeycomb sandwich structural panel was designed to sustain 5000 cycles of cyclic in-plane loading of + or - 210 kN/m (+ or - 1200 lbf/in.) combined with a uniform panel pressure of + or - 6.89 kPa (?1.0 psi).

Ellis, D. A.

Evaluation of a large capacity heat pump concept for active cooling of hypersonic aircraft structure

Results of engineering analyses assessing the conceptual feasibility of a large capacity heat pump for enhancing active cooling of hypersonic aircraft structure are presented. A unique heat pump arrangement which permits cooling the structure of a Mach 6 transport to aluminum temperatures without the aid of thermal shielding is described. The selected concept is compatible with the use of conventional refrigerants, with Freon R-11 selected as the preferred refrigerant. Condenser temperatures were limited to levels compatible with the use of conventional refrigerants by incorporating a unique multipass condenser design, which extracts mechanical energy from the hydrogen fuel, prior to each subsequent pass through the condenser. Results show that it is technically feasible to use a large capacity heat pump in lieu of external shielding. Additional analyses are required to optimally apply this concept.

Pagel, L. L.

Integrated temperature sensor

Proposed temperature-sensor/failure-detection system utilizes liquid-filled sensors attached as matrix to monitored surface. Fluid passages are integral part of monitored surface or are small-diameter tubing in good thermal contact with monitored surface. System offers significant advantages over discrete sensors in terms of simplicity, reliability, cost, ease of installation, maintainability, and weight.

Herring, R. L.