Search NASA⌕ Search

Engineering topics

Palacio, J. [LSC, Canfranc] (ORCID:000000030374100X)

Publications and source records attributed to Palacio, J. [LSC, Canfranc] (ORCID:000000030374100X).

Radon-induced backgrounds in the NEXT-100 experiment

The NEXT-100 detector at the LSC aims at the first competitive search for the 0νββ decay using a high-pressure $^{136}$Xe electroluminescent time projection chamber. The first low-background run of NEXT-100 at 3.95 bar has been devoted to the measurement of the radon-induced backgrounds impacting this search. The contributions from both the internal and external airborne radon have been evaluated. The internal $^{222}$Rn activity is found to be (0.95±0.04(stat)±0.09(sys)) Bq/m$^{3}$, while no traces of $^{220}$Rn have been observed. Most of the $^{222}$Rn progeny plate-out on the surface of the cathode of the detector, leading to a rate of Rn-induced $^{214}$Bi of (0.97±0.05(stat)±0.10(sys)) Hz for visible energies above 400 keV. The corresponding background index in the 0νββ region of interest is evaluated as (7.3±1.5(stat)±0.8(sys))×10$^{−4}$ counts/(keV·kg·yr) after selection of the fully contained events. This background index is reduced to ∼4×10$^{−5}$ counts/(keV·kg·yr) by applying a topological selection requiring only one double-electron-like track in the events. This value is one order of magnitude below the total radiogenic background expectation in NEXT-100. By analyzing the correlation of the airborne radon activity and the measured rate of events in NEXT-100, it is concluded that the detector operates in a virtually radon-free environment thanks to the radon abatement system of the LSC.[graphic not available: see fulltext]

Cortes-Parra, C. [Valencia U., IFIC] (ORCID:000000↗

First results of the NEXT-100 detector using $^{83m}$Kr decays

The NEXT collaboration is investigating the double beta decay of $ ^{136}\mathrm Xe$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $^{83\text {m}}\textrm{Kr}$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $^{83\text {m}}\textrm{Kr}$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $E^{-1/2}$ extrapolation to $Q_{\beta \beta }$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.

Martínez-Lema, G. [Donostia Intl. Phys. Ctr., San ↗