Porous mesh manifold for enhanced boiling performance

High-performance electronics are continuously demanding cooling of higher heat fluxes. Phase-change cooling, including pool boiling, is a useful approach to address this challenge; however, competition between liquid and vapor flows generally limit the heat fluxes that can be dissipated. A range of strategies to control these flows have been investigated previously, including capillary guides. Here a manifold structure formed from a metallic mesh is investigated to control the disposition of liquid and vapor phases above a pool fed boiling surface enhanced with porous structures. Copper mesh forms defined liquid flow paths, using capillary action to guide and distribute liquid evenly over the heated surface, along with open channels to facilitate vapor escape. The mesh provides a novel structure for liquid guidance that imposes low resistance to liquid flow while occluding a minimal area of heated surface underneath. The manifold performance is characterized in boiling fed by a pool of water above a laser-textured aluminum nitride heat dissipation surface with pin–fin structures having heights of 110 µm and spacing of 30 µm with a heated area of 5 mm x 5 mm. A maximum heat flux of 490 W/cm 2 is reached with the manifold in the pool fed configuration, representing an increase of more than 65% over the porous pin fin surface alone. The maximum stable superheat observed for the manifold of 36K is 14K higher than that for the porous surface without the manifold. The factors limiting performance of the manifold are analyzed. High superheat is attributed to partial flooding of the boiling surface as suggested by the reduction in superheat using external suction. Similar systems and structures for enhanced two-phase cooling are compared.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Permeability of Single–Layer–Free–Standing Meshes at Varying Capillary Pressure via a Novel Method

The permeability of mesh wicks is important for various applications, including two–phase heat transfer. However, the understanding of the permeability of single–layer, free–standing mesh wicks, with liquid–gas interfaces on both sides, is limited. A novel and simpler method is presented to determine the permeability of a free–standing wick and apply it to a representative mesh. This method involves modifying the capillary pressure via elevation and simultaneously measuring the permeability to determine the permeability–capillary pressure relationship. When applied to a copper mesh with plain weave having undergone surface cleaning, the permeability is found to decrease as capillary pressure for deionized water increases. A dimensional analysis is presented to generalize this data for other mesh sizes with similar weaves and fluids. The behavior of mesh in application is modeled, based on the integration of Darcy's law with an analytic function fit to measured data, and parametric studies are conducted to investigate the superficial velocity of liquids through the mesh under varying driving pressures, transport lengths, and liquid viscosity, based on the obtained capillary pressure–permeability relationship. This study provides valuable insights into the transport properties of mesh wicks, with potential applications in fields such as electronics cooling, electrochemical devices, and fluid purification technologies.

36 MATERIALS SCIENCE↗

Single-Crystal Elastic Constants of Yttria (Y2O3) Measured to High Temperatures

Yttria, or yttrium sesquioxide (Y2O3), has been considered for use in nuclear applications and has gained interest relatively recently for use in infrared optics. Single crystals of yttria have been grown successfully at the NASA Glenn Research Center using a laser-heated float zone technique in a fiber and rod. Such samples allow measurement of the single-crystal elastic properties, and these measurements provide useful property data for the design of components using single crystals. They also yield information as to what degree the elastic properties of yttria ceramics are a result of the intrinsic properties of the yttria crystal in comparison to characteristics that may depend on processing, such as microstructure and intergranular phases, which are common in sintered yttria. The single-crystal elastic moduli are valuable for designing such optical components. In particular, the temperature derivatives of elastic moduli allow the dimensional changes due to heating under physical constraints, as well as acoustic excitation, to be determined. The single-crystal elastic moduli of yttria were measured by Brillouin spectroscopy up to 1200 C. The room-temperature values obtained were C(sub 11) = 223.6 + 0.6 GPa, C(sub 44) = 74.6 + 0.5 GPa, and C(sub 12) = 112.4 + 1.0 GPa. The resulting bulk and (Voigt-Reuss-Hill) shear moduli were K = 149.5 + 1.0 GPa and G(sub VRH) = 66.3 + 0.8 GPa, respectively. Linear least-squares regressions to the variation of bulk and shear moduli with temperature resulted in derivatives of dK/dT = -17 + 2 MPa/C and dG(sub VRH)/dT = -8 + 2 MPa/ C. Elastic anisotropy was found to remain essentially constant over the temperature range studied.

Sayir, Ali↗

High Temperature Elastic Properties of Single Crystal Mullite (Approximately 2.5Al2O3.SiO2) by Brillouin Spectroscopy

The complete elastic tensor of mullite has been determined by brillouin spectroscopy at room temperature and elevated temperatures up to 1200C. Equivalent, isotropic moduli (bulk, shear, and Young's) have been calculated. The room temperature values obtained using Voigt-Reuss-Hill averaging are: K(sub VRH) = 173.5 + 6.9 GPa, G(sub VRH) = 88.0 + 3.5 GPa, E(sub VRH) = 225.9 + 9.0 GPa. All moduli show relatively gradual decreases with temperature. The temperature derivatives obtained for the equivalent, isotropic moduli are: dK(sub VRH)/dT = - 17.5 + 2.5 MPa/deg. C, dG(sub VRH)/dT = -8.8 + 1.4 MPa/deg. C, dE(sub VRH)/dT = -22.6 + 2.8 MPa/deg C. Substantial differences between bulk properties calculated from the single crystal measurements in this study and the properties reported in the literature for polycrystalline sintered mullite are identified, indicating the importance of factors such as microstructure, intergranular phases, and composition to the elasticity of mullite ceramics.

Palko, James W.↗

The Single-Crystal Elasticity of Yttria (Y2O3) to High Temperature

The single-crystal elastic moduli of yttria have been measured by Brillouin spectroscopy up to 1200 C. The room temperature values obtained are C11 = 223.6 +/- 0.6 GPa, C44 = 74.6 +/- 0.5 GPa, and C12 = 112.4 +/- 1.0 GPa. The resulting bulk and (Voigt-Reuss-Hill) shear moduli are K = 149.5 +/- 1.0 GPa and G(sub VRH) = 66.3 +/- 0.8 GPa, respectively. These agree much more closely with experimental values reported for polycrystalline samples than do previous single-crystal measurements. Linear least squares regressions to the variation of bulk and shear moduli with temperature result in derivatives of dK/dT = -17 +/- 2 MPa/degC and dG(sub VRH)/dT = -8 +/- 2 MPa/degC. Elastic anisotropy was found to remain essentially constant over the temperature range studied.

Kriven, Waltraud M.↗