Search NASA⌕ Search

Engineering topics

Palmer, Robert

Publications and source records attributed to Palmer, Robert.

Progress on the design of the interaction region of the Electron-Ion Collider EIC

We present an update on the design of the Interaction Region (IR) for the the Electron Ion Collider (EIC) being built at Brookhaven National Laboratory (BNL). The EIC will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV with luminosities of up to 10^34 /cm^2/s. The IR, located at RHIC's IR6, is designed to meet the requirements of the nuclear physics community as outlined in [1]. A second IR is technically feasible but not part of the project.The magnet apertures are sufficiently large to allow desired collision products to reach the far-forward detectors; the electron magnet apertures in the rear direction are chosen to be large enough to pass the synchrotron radiation fan. In the forward direction the electron apertures are large enough for non-Gaussian tails.The paper discusses a number of recent recent changes to the design. The machine free region was recently increased from 9 to 9.5 m to allow for more space in the forward direction for the detector. The superconducting magnets on the forward side now operate at 1.9 K, which helps crosstalk and space issues.

43 PARTICLE ACCELERATORS↗

A Primer on Phased Array Radar Technology for the Atmospheric Sciences

The scientific community has expressed interest in the potential of phased array radars (PARs) to observe the atmosphere with finer spatial and temporal scales. Although convergence has occurred between the meteorological and engineering communities, the need exists to increase access of PAR to meteorologists. Here, we facilitate these interdisciplinary efforts in the field of ground-based PARs for atmospheric studies. We cover high-level technical concepts and terminology for PARs as applied to studies of the atmosphere. A historical perspective is provided as context along with an overview of PAR system architectures, technical challenges, and opportunities. Envisioned scan strategies are summarized because they are distinct from traditional mechanically scanned radars and are the most advantageous for high-resolution studies of the atmosphere. Further, open access to PAR data is emphasized as a mechanism to educate the future generation of atmospheric scientists. Finally, a vision for the future of operational networks, research facilities, and expansion into complementary radar wavelengths is provided.

47 OTHER INSTRUMENTATION↗

Science Applications of Phased Array Radars

Phased array radars (PARs) are a promising observing technology, at the cusp of being available to the broader meteorological community. PARs offer near instantaneous sampling of the atmosphere with flexible beam forming, multi-functionality, low operational and maintenance costs, and without mechanical inertia limitations. These PAR features are transformative compared to those offered by our current reflector-based meteorological radars. The integration of PARs into meteorological research has the potential to revolutionize the way we observe the atmosphere. The rate of adoption of PARs in research will depend on many factors including i) the need to continue educating the scientific community on the full technical capabilities and trade-offs of PARs through an engaging dialogue with the science and engineering communities and ii) the need to communicate the breadth of scientific bottlenecks that PARs can overcome in atmospheric measurements and the new research avenues that are now possible using PARs in concert with other measurement systems. The former is the subject of a companion article that focuses on PAR technology while the latter is the objective here.

54 ENVIRONMENTAL SCIENCES↗

Design of a tapered final focusing magnet for eRHIC

Presently the electron-ion collider eRHIC is underdesign, which aims to provide a facility with a peak luminosity of 10 34 cm –2 sec –1 . Particularly challenging in terms of magnet design are the IR magnets due to the close proximity of the electron and hadron beams. This paper outlines the design for the so-called Q1 rear side magnet, which is a double aperture quadrupole magnet 7.2 m from the interaction region. Due to space restrictions both magnets are housed in the same iron yoke. The aperture of the hadron quadrupole is relatively small, but requires high gradients. While the required gradient for the electron quadrupole is relatively small, the aperture of this magnet needs to accommodate the beam and allow the synchrotron radiation fan to pass through. To accomplish this both quadrupole magnets have a tapered aperture. Furthermore to keep the gradients constant along the length of the magnets a special winding pattern has been identified, which is described in this paper.

43 PARTICLE ACCELERATORS↗

Low temperature superconductor and aligned high temperature superconductor magnetic dipole system and method for producing high magnetic fields

A dipole-magnet system and method for producing high-magnetic-fields, including an open-region located in a radially-central-region to allow particle-beam transport and other uses, low-temperature-superconducting-coils comprised of low-temperature-superconducting-wire located in radially-outward-regions to generate high magnetic-fields, high-temperature-superconducting-coils comprised of high-temperature-superconducting-tape located in radially-inward-regions to generate even higher magnetic-fields and to reduce erroneous fields, support-structures to support the coils against large Lorentz-forces, a liquid-helium-system to cool the coils, and electrical-contacts to allow electric-current into and out of the coils. The high-temperature-superconducting-tape may be comprised of bismuth-strontium-calcium-copper-oxide or rare-earth-metal, barium-copper-oxide (ReBCO) where the rare-earth-metal may be yttrium, samarium, neodymium, or gadolinium. Advantageously, alignment of the large-dimension of the rectangular-cross-section or curved-cross-section of the high-temperature-superconducting-tape with the high-magnetic-field minimizes unwanted erroneous magnetic fields. Alignment may be accomplished by proper positioning, tilting the high-temperature-superconducting-coils, forming the high-temperature-superconducting-coils into a curved-cross-section, placing nonconducting wedge-shaped-material between windings, placing nonconducting curved-and-wedge-shaped-material between windings, or by a combination of these techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗