Search NASA⌕ Search

Engineering topics

Pan, Xiaochuan

Publications and source records attributed to Pan, Xiaochuan.

Exploiting voxel-sparsity for bone imaging with sparse-view cone-beam computed tomography

An optimization-based image reconstruction frame work is developed specifically for bone imaging. This framework exploits voxel-sparsity by use of ℓ 1 -norm image regularization and it enables image reconstruction from sparse-view cone-beam computed tomography (CBCT) acquisition. The effectiveness of the voxel-sparsity regularization is enhanced by using a blurred image representation. Ramp-filtering is included in the data discrepancy term and it has the effect of acting as a preconditioner, reducing the necessary number of iterations. The bone image reconstruction framework is demonstrated on CBCT data taken from an equine metacarpal condyle specimen.

Bone imaging↗

Projection of temperature-related mortality due to cardiovascular disease in beijing under different climate change, population, and adaptation scenarios

Highlights: • The population change can bring 5 times growth to temperature-related CVD deaths. • Increase of heat-related CVD deaths is higher than decrease of cold-related ones. • The adaptation to climate change may cause more temperature-related CVD deaths. Human health faces unprecedented challenges caused by climate change. Thus, studies of the effect of temperature change on total mortality have been conducted in numerous countries. However, few of those studies focused on temperature-related mortality due to cardiovascular disease (CVD) or considered future population changes and adaptation to climate change. We present herein a projection of temperature-related mortality due to CVD under different climate change, population, and adaptation scenarios in Beijing, a megacity in China. To this end, 19 global circulation models (GCMs), 3 representative concentration pathways (RCPs), 3 socioeconomic pathways, together with generalized linear models and distributed lag non-linear models, were used to project future temperature-related CVD mortality during periods centered around the years 2050 and 2070. The number of temperature-related CVD deaths in Beijing is projected to increase by 3.5–10.2% under different RCP scenarios compared with that during the baseline period. Using the same GCM, the future daily maximum temperatures projected using the RCP2.6, RCP4.5, and RCP8.5 scenarios showed a gradually increasing trend. When population change is considered, the annual rate of increase in temperature-related CVD deaths was up to fivefold greater than that under no-population-change scenarios. The decrease in the number of cold-related deaths did not compensate for the increase in that of heat-related deaths, leading to a general increase in the number of temperature-related deaths due to CVD in Beijing. In addition, adaptation to climate change may enhance rather than ameliorate the effect of climate change, as the increase in cold-related CVD mortality greater than the decrease in heat-related CVD mortality in the adaptation scenarios will result in an increase in the total number of temperature-related CVD mortalities.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of a data fusion approach to estimate daily PM{sub 2.5} levels in North China

PM{sub 2.5} air pollution has been a growing concern worldwide. Previous studies have conducted several techniques to estimate PM{sub 2.5} exposure spatiotemporally in China, but all these have limitations. This study was to develop a data fusion approach and compare it with kriging and Chemistry Module. Two techniques were applied to create daily spatial cover of PM{sub 2.5} in grid cells with a resolution of 10 km in North China in 2013, respectively, which was kriging with an external drift (KED) and Weather Research and Forecast Model with Chemistry Module (WRF-Chem). A data fusion technique was developed by fusing PM{sub 2.5} concentration predicted by KED and WRF-Chem, accounting for the distance from the central of grid cell to the nearest ground observations and daily spatial correlations between WRF-Chem and observations. Model performances were evaluated by comparing them with ground observations and the spatial prediction errors. KED and data fusion performed better at monitoring sites with a daily model R{sup 2} of 0.95 and 0.94, respectively and PM{sub 2.5} was overestimated by WRF-Chem (R{sup 2}=0.51). KED and data fusion performed better around the ground monitors, WRF-Chem performed relative worse with high prediction errors in the central of study domain. In our study, both KED and data fusion technique provided highly accurate PM{sub 2.5}. Current monitoring network in North China was dense enough to provide a reliable PM{sub 2.5} prediction by interpolation technique. - Highlights: • KED and data fusion model predicted daily PM{sub 2.5} with high accuracy. • WRF-Chem performed worse in PM{sub 2.5} prediction compared with KED and data fusion. • The PM{sub 2.5} monitoring network in North China was able to support reliable PM{sub 2.5} interpolation.

54 ENVIRONMENTAL SCIENCES↗

X-ray tomography system to investigate granular materials during mechanical loading

We integrate a small and portable medical x-ray device with mechanical testing equipment to enable in situ, non-invasive measurements of a granular material's response to mechanical loading. We employ an orthopedic C-arm as the x-ray source and detector to image samples mounted in the materials tester. We discuss the design of a custom rotation stage, which allows for sample rotation and tomographic reconstruction under applied compressive stress. We then discuss the calibration of the system for 3D computed tomography, as well as the subsequent image reconstruction process. Using this system to reconstruct packings of 3D-printed particles, we resolve packing features with 0.52 mm resolution in a (60 mm){sup 3} field of view. By analyzing the performance bounds of the system, we demonstrate that the reconstructions exhibit only moderate noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A constrained, total-variation minimization algorithm for low-intensity x-ray CT

Purpose: The authors developed an iterative image-reconstruction algorithm for application to low-intensity computed tomography projection data, which is based on constrained, total-variation (TV) minimization. The algorithm design focuses on recovering structure on length scales comparable to a detector bin width. Methods: Recovering the resolution on the scale of a detector bin requires that pixel size be much smaller than the bin width. The resulting image array contains many more pixels than data, and this undersampling is overcome with a combination of Fourier upsampling of each projection and the use of constrained, TV minimization, as suggested by compressive sensing. The presented pseudocode for solving constrained, TV minimization is designed to yield an accurate solution to this optimization problem within 100 iterations. Results: The proposed image-reconstruction algorithm is applied to a low-intensity scan of a rabbit with a thin wire to test the resolution. The proposed algorithm is compared to filtered backprojection (FBP). Conclusions: The algorithm may have some advantage over FBP in that the resulting noise level is lowered at equivalent contrast levels of the wire.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image reconstruction exploiting object sparsity in boundary-enhanced X-ray phase-contrast tomography

Propagation-based X-ray phase-contrast tomography (PCT) seeks to reconstruct information regarding the complex-valued refractive index distribution of an object. In many applications, a boundary-enhanced image is sought that reveals the locations of discontinuities in the real-valued component of the refractive index distribution. We investigate two iterative algorithms for few-view image reconstruction in boundary-enhanced PCT that exploit the fact that a boundary-enhanced PCT image, or its gradient, is often sparse. In order to exploit object sparseness, the reconstruction algorithms seek to minimize the {ell}{sub 1}-norm or TV-norm of the image, subject to data consistency constraints. We demonstrate that the algorithms can reconstruct accurate boundary-enhanced images from highly incomplete few-view projection data.

47 OTHER INSTRUMENTATION↗

Feature-based characterization of motion-contaminated calcified plaques in cardiac multidetector CT

In coronary calcium scoring, motion artifacts affecting calcified plaques are commonly characterized using descriptive terms, which incorporate an element of subjectivity in their interpretations. Quantitative indices may improve the objective characterization of these motion artifacts. In this paper, an automated method for generating 12 quantitative indices, i.e., features that characterize the motion artifacts affecting calcified plaques, is presented. This method consists of using the rapid phase-correlated region-of-interest (ROI) tracking algorithm for reconstructing ROI images of calcified plaques automatically from the projection data obtained during a cardiac scan, and applying methods for extracting features from these images. The 12 features include two dynamic, six morphological, and four intensity-based features. The two dynamic features are three-dimensional (3D) velocity and 3D acceleration. The six morphological features include edge-based volume, threshold-based volume, sphericity, irregularity, average margin gradient, and variance of margin gradient. The four intensity-based features are maximum intensity, mean intensity, minimum intensity, and standard deviation of intensity. The 12 features were extracted from 54 reconstructed sets of simulated four-dimensional images from the dynamic NCAT phantom involving six calcified plaques under nine heart rate/multi-sector gating combinations. In order to determine how well the 12 features correlated with a plaque motion index, which was derived from the trajectory of the plaque, partial correlation coefficients adjusted for heart rate, number of gated sectors, and mean feature values of the six plaques were calculated for all 12 features. Features exhibiting stronger correlations (|r| set-membership sign [0.60,1.00]) with the motion index were 3D velocity, maximum intensity, and standard deviation of intensity. Features demonstrating stronger correlations (|r| set-membership sign [0.60,1.00]) with other features mostly involved intensity-based features. Edge-based volume/irregularity and average margin gradient/variance of margin gradient were the only two feature pairs out of 12 with stronger correlations that did not involve intensity-based features. Automatically extracted features of the motion artifacts affecting calcified plaques in cardiac computed tomography images potentially can be used to develop models for predicting image assessability with respect to motion artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗