Search NASA⌕ Search

Engineering topics

Papiez, Lech

Publications and source records attributed to Papiez, Lech.

Target tracking using DMLC for volumetric modulated arc therapy: A simulation study

Purpose: Target tracking using dynamic multileaf collimator (DMLC) is a promising approach for intrafraction motion management in radiation therapy. The purpose of this work is to develop a DMLC tracking algorithm capable of delivering volumetric-modulated arc therapy (VMAT) to the targets that experience two-dimensional (2D) rigid motion in the beam's eye view. Methods: The problem of VMAT delivery to moving targets is formulated as a control problem with constraints. The relationships between gantry speed, gantry acceleration, MLC leaf-velocity, dose rate, and target motion are derived. An iterative search algorithm is developed to find numerical solutions for efficient delivery of a specific VMAT plan to the moving target using 2D DMLC tracking. The delivery of five VMAT lung plans is simulated. The planned and delivered fluence maps in the target-reference frame are calculated and compared. Results: The simulation demonstrates that the 2D tracking algorithm is capable of delivering the VMAT plan to a moving target fast and accurately without violating the machine constraints and the integrity of the treatment plan. The average delivery time is only 29 s longer than that of no-tracking delivery, 101 versus 72 s, respectively. The fluence maps are normalized to 200 MU and the average root-mean-square error between the desired and the delivered fluence is 2.1 MU, compared to 14.8 MU for no-tracking and 3.6 MU for one-dimensional tracking. Conclusions: A locally optimal MLC tracking algorithm for VMAT delivery is proposed, aiming at shortest delivery time while maintaining treatment plan invariant. The inconsequential increase of treatment time due to DMLC tracking is clinically desirable, which makes VMAT with DMLC tracking attractive in treating moving tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Early-Stage Non-Small-Cell Lung Carcinoma: Four-Year Results of a Prospective Phase II Study

Purpose: The 50-month results of a prospective Phase II trial of stereotactic body radiation therapy (SBRT) in medically inoperable patients are reported. Methods and Materials: A total of 70 medically inoperable patients had clinically staged T1 (34 patients) or T2 (36 patients) (<=7 cm), N0, M0, biopsy-confirmed non-small-cell lung carcinoma (NSCLC) and received SBRT as per our previously published reports. The SBRT treatment dose of 60-66 Gy was prescribed to the 80% isodose volume in three fractions. Results: Median follow-up was 50.2 months (range, 1.4-64.8 months). Kaplan-Meier local control at 3 years was 88.1%. Regional (nodal) and distant recurrence occurred in 6 (8.6%) and 9 (12.9%) patients, respectively. Median survival (MS) was 32.4 months and 3-year overall survival (OS) was 42.7% (95% confidence interval [95% CI], 31.1-54.3%). Cancer-specific survival at 3 years was 81.7% (95% CI, 70.0-93.4%). For patients with T1 tumors, MS was 38.7 months (95% CI, 25.3-50.2) and for T2 tumors MS was 24.5 months (95% CI, 18.5-37.4) (p = 0.194). Tumor volume (<=5 cc, 5-10 cc, 10-20 cc, >20 cc) did not significantly impact survival: MS was 36.9 months (95% CI, 18.1-42.9), 34.0 (95% CI, 16.9-57.1), 32.8 (95% CI, 21.3-57.8), and 21.4 months (95% CI, 17.8-41.6), respectively (p = 0.712). There was no significant survival difference between patients with peripheral vs. central tumors (MS 33.2 vs. 24.4 months, p = 0.697). Grade 3 to 5 toxicity occurred in 5 of 48 patients with peripheral lung tumors (10.4%) and in 6 of 22 patients (27.3%) with central tumors (Fisher's exact test, p = 0.088). Conclusion: Based on our study results, use of SBRT results in high rates of local control in medically inoperable patients with Stage I NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

General strategy for the protection of organs at risk in IMRT therapy of a moving body

We investigated protection strategies of organs at risk (OARs) in intensity modulated radiation therapy (IMRT). These strategies apply to delivery of IMRT to moving body anatomies that show relative displacement of OAR in close proximity to a tumor target. We formulated an efficient genetic algorithm which makes it possible to search for global minima in a complex landscape of multiple irradiation strategies delivering a given, predetermined intensity map to a target. The optimal strategy was investigated with respect to minimizing the dose delivered to the OAR. The optimization procedure developed relies on variability of all parameters available for control of radiation delivery in modern linear accelerators, including adaptation of leaf trajectories and simultaneous modification of beam dose rate during irradiation. We showed that the optimization algorithms lead to a significant reduction in the dose delivered to OAR in cases where organs at risk move relative to a treatment target.

61 RADIATION PROTECTION AND DOSIMETRY↗