Search NASA⌕ Search

Engineering topics

Park, J.

Publications and source records attributed to Park, J..

At least 19 records

Precise measurement of nuclear interaction cross sections towards neutron-skin determination with R 3 B

The R 3 B (Reactions with Relativistic Radioactive Beams) experiment as a major instrument of the NUSTAR collaboration for the research facility FAIR in Darmstadt is designed for kinematically complete studies of reactions with high-energy radioactive beams. Part of the broad physics program of R 3 B is to constrain the asymmetry term in the nuclear equation-of-state and hence improve the description of highly asymmetric nuclear matter (e.g., in neutron stars). For a precise determination of the neutron-skin thickness – an observable which is directly correlated with the symmetry energy in theoretical calculations – by measuring absolute fragmentation cross sections, it is essential to quantify the uncertainty and challenge the reaction model under stable conditions. During the successful FAIR Phase-0 campaign of R 3 B, we precisely measured the energy dependence of total interaction cross sections in 12 C + 12 C collisions, for a direct comparison with calculations based on the eikonal reaction theory.

Ponnath, L. (ORCID:0000000286742624)↗

Enhanced plasma performance in C-2W advanced beam-driven field-reversed configuration experiments

TAE Technologies’ fifth-generation fusion device, C-2W (also called ‘Norman’), is the world’s largest compact-toroid device and has made significant progress in field-reversed configuration (FRC) plasma performance. C-2W produces record breaking, macroscopically stable, high-temperature advanced beam-driven FRC plasmas, dominated by injected fast particles and sustained in steady state, which is primarily limited by neutral-beam (NB) pulse duration. The NB power supply system has recently been upgraded to extend the pulse length from 30 ms to 40 ms, which allows for a longer plasma lifetime and thus better characterization and further enhancement of FRC performance. An active plasma control system is routinely used in C-2W to produce consistent FRC performance as well as for reliable machine operations using magnet coils, edge-biasing electrodes, gas injection and tunable-energy NBs. Google’s machine learning framework for experimental optimization has also been routinely used to enhance plasma performance. D

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of nuclear interaction cross sections towards neutron-skin thickness determination

The accuracy of reaction theories used to extract properties of exotic nuclei from scattering experiments is often unknown or not quantified, but of utmost importance when, e.g., constraining the equation of state of asymmetric nuclear matter from observables as the neutron-skin thickness. In order to test the Glauber multiple-scattering model, the total interaction cross section of 12 C on carbon targets was measured at initial beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The measurements were performed during the first experiment of the newly constructed R 3 B (Reaction with Relativistic Radioactive Beams) experiment after the start of FAIR Phase-0 at the GSI/FAIR facility with beam energies of 400, 550, 650, 800, and 1000 MeV/nucleon. The combination of the large-acceptance dipole magnet GLAD and a newly designed and highly efficient Time-of-Flight detector enabled a precise transmission measurement with several target thicknesses for each initial beam energy with an experimental uncertainty of ±0.4%. A comparison with the Glauber model revealed a discrepancy of around 3.1% at higher beam energies, which will serve as a crucial baseline for the model-dependent uncertainty in future fragmentation experiments.

Astronomy & Astrophysics↗

Differentiating multi-MeV, multi-ion spectra with CR-39 solid-state nuclear track detectors

The development of high intensity petawatt lasers has created new possibilities for ion acceleration and nuclear fusion using solid targets. In such laser-matter interaction, multiple ion species are accelerated with broad spectra up to hundreds of MeV. To measure ion yields and for species identification, CR-39 solid-state nuclear track detectors are frequently used. However, these detectors are limited in their applicability for multi-ion spectra differentiation as standard image recognition algorithms can lead to a misinterpretation of data, there is no unique relation between track diameter and particle energy, and there are overlapping pit diameter relationships for multiple particle species. In this report, we address these issues by first developing an algorithm to overcome user bias during image processing. Second, we use calibration of the detector response for protons, carbon and helium ions (alpha particles) from 0.1 to above 10 MeV and measurements of statistical energy loss fluctuations in a forward-fitting procedure utilizing multiple, differently filtered CR-39, altogether enabling high-sensitivity, multi-species particle spectroscopy. To validate this capability, we show that inferred CR-39 spectra match Thomson parabola ion spectrometer data from the same experiment. Filtered CR-39 spectrometers were used to detect, within a background of ~ 2 × 10 11 sr -1 J -1 protons and carbons, (1.3 ± 0.7) × 10 8 sr -1 J -1 alpha particles from laser-driven proton-boron fusion reactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variable magnetic field electron spectrometer to measure hot electrons in the range of 50–460 keV

Resonance absorption (RA) occurs when a p-polarized electromagnetic wave, obliquely incident on an inhomogeneous plasma, tunnels past its turning point and resonantly excites an electron plasma wave (EPW) at the critical density. This phenomenon is important, for instance, in the direct drive approach to inertial fusion energy and is a particular example of a wider phenomenon in plasma physics known as mode conversion, which is crucial for heating magnetic fusion devices, such as tokamaks, via RF heating. Direct measurement of these RA-generated EPW accelerated hot electrons, with energy in the range of a few tens to a few hundreds of keV, is a challenging task due to the relatively low deflecting magnetic fields needed. The solution described here is a magnetic electron spectrometer (MES) with a continually changing magnetic field, lower at the entrance of the MES and gradually increasing toward the end, that enables the measurement of a wide spectral range of electrons with energies between 50 and 460 keV. Electron spectra taken in a LaserNetUS RA experiment were acquired from plasmas generated by irradiating polymer targets with the combination of an ~300 ps pulse followed by a series of ten high intensity 50–200 fs duration laser pulses from the ALEPH laser at Colorado State University. In conclusion, the high intensity beam is designed as spike trains of uneven duration and delay pulses in order to modify the RA phenomenon.

47 OTHER INSTRUMENTATION↗

A flexible proton beam imaging energy spectrometer (PROBIES) for high repetition rate or single-shot high energy density (HED) experiments (invited)

The PROBIES diagnostic is a new, highly flexible, imaging and energy spectrometer designed for laser-accelerated protons. The diagnostic can detect low-mode spatial variations in the proton beam profile while resolving multiple energies on a single detector or more. When a radiochromic film stack is employed for “single-shot mode,” the energy resolution of the stack can be greatly increased while reducing the need for large numbers of films; for example, a recently deployed version allowed for 180 unique energy measurements spanning ~3 to 75 MeV with <0.4 MeV resolution using just 20 films vs 180 for a comparable traditional film and filter stack. When utilized with a scintillator, the diagnostic can be run in high-rep-rate (>Hz rate) mode to recover nine proton energy bins. Here, we also demonstrate a deep learning-based method to analyze data from synthetic PROBIES images with greater than 95% accuracy on sub-millisecond timescales and retrained with experimental data to analyze real-world images on sub-millisecond time-scales with comparable accuracy.

3D printing↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Ultra-compact x-ray spectrometer for high-repetition-rate laser–plasma experiments

Here, we present in this work the development of an ultra-compact, multi-channel x-ray spectrometer (UCXS). This diagnostic has been specially built and adapted to perform at high-repetition-rate (>1 Hz) for high-intensity, short-pulse laser plasma experiments. X-ray filters of varying materials and thicknesses are chosen to provide spectral resolution up to ΔE ≈ 1 keV over the x-ray energy range of 1–30 keV. These filters are distributed over a total of 25 channels, where each x-ray filter is coupled to a single scintillator. The UCXS is designed to detect and resolve a large variety of laser-driven x-ray sources such as low energy bremsstrahlung emission, fluorescence, and betatron radiation (up to 30 keV). Preliminary results from commissioning experiments at the ABL laser facility at Colorado State University are provided.

47 OTHER INSTRUMENTATION↗

Reactivity initiated accident uncertainty quantification for fuel assembly with subchannel code

UNIST CORE lab has developed a multiphysics coupling framework (MPCORE) consisting of Neutronics, Thermal Hydraulics and Fuel Performance modules. It can accommodate one-dimensional as well as sub-channel code Thermal Hydraulics (TH) module. Generally, running a transient requires more computational power due to the convergence of modules with each other. The difference between one-dimensional and sub-channel TH modules is studied in this research for a Reactivity Initiated Accident (RIA). Both TH modules are compared for a RIA uncertainty propagation in a single VERA fuel assembly with 2.11% enrichment. MPCORE is capable of analyzing the transient at any burnup point but for current work, only fresh fuel has been considered. The results have been obtained using dynamic gap heat conductance in FRAPTRAN. Peak centerline temperature, fuel enthalpy and DNBR are compared for both the approaches. The results indicate that the use of sub-channel code lead to greater safety margin for critical parameters. Computation time comparison is also presented for both the cases. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental verification of TNSA protons and deuterons in the multi-picosecond moderate intensity regime

Ion acceleration from high intensity short pulse laser interactions is of great interest due to a number of applications, and there has been significant work carried out with laser energies up to a few 100 J with 10's of femtosecond to 1 ps pulse durations. Here, we report results from an experiment at the OMEGA EP laser, where laser energy and pulse length were varied from 100 to 1250 J and 0.7–30 ps, respectively, in the moderate (2 × 10 17 –2 × 10 18 W/cm 2 ) laser intensity regime. Ions and electrons were simultaneously measured from disk targets made of CH and CD by a Thomson parabola and a magnetic spectrometer, respectively. Measurements showed that the electron temperature, T e (MeV), has a dependence on the laser energy, E L (J), and pulse duration, τ L (ps), and its empirical scaling was found to be 0.015 × E L 0.90 τ L –0.48. The maximum proton and deuteron energies are linearly dependent on the electron temperature, (5.60 ± 0.26) × T e and (3.17 ± 0.18) × T e , respectively. A significant increase in proton numbers with the laser energy was also observed. Furthermore, the increase in the maximum proton energy and proton count with higher energy longer duration pulses presented in this article shows that such laser conditions have a great advantage for applications, such as the proton radiograph, in the moderate laser intensity regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coulomb excitation of the | T z | = 1 2 , A = 23 mirror pair

Background: Electric-quadrupole ( E 2 ) strengths relate to the underlying quadrupole deformation of a nucleus and present a challenge for many nuclear theories. Additionally, mirror nuclei in the vicinity of the line of N = Z represent a convenient laboratory for testing deficiencies in such models, making use of the isospin symmetry of the systems. Purpose: Uncertainties associated with literature E 2 strengths in Mg 23 are some of the largest in T z = | 1 2 | nuclei in the s d shell. The purpose of the present paper is to improve the precision with which these values are known, to enable better comparison with theoretical models. Methods: Coulomb-excitation measurements of Mg 23 and Na 23 were performed at the TRIUMF-ISAC facility using the TIGRESS spectrometer. They were used to determine the E 2 matrix elements of mixed E 2 / M 1 transitions. Results: Reduced E 2 transition strengths, B ( E 2 ) , were extracted for Mg 23 and Na 23 . Their precision was improved by factors of approximately 6 for both isotopes, while agreeing within uncertainties with previous measurements. Conclusions: A comparison was made with both shell-model and ab initio valence-space in-medium similarity renormalization group calculations. Valence-space in-medium similarity renormalization group calculations were found to underpredict the absolute E 2 strength, in agreement with previous studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗