Search NASA⌕ Search

Engineering topics

Park, Junghyun

Publications and source records attributed to Park, Junghyun.

Roadmap for Optical Metasurfaces

Metasurfaces have recently risen to prominence in optical research, providing unique functionalities that can be used for imaging, beam forming, holography, polarimetry, and many more, while keeping device dimensions small. Despite the fact that a vast range of basic metasurface designs has already been thoroughly studied in the literature, the number of metasurface-related papers is still growing at a rapid pace, as metasurface research is now spreading to adjacent fields, including computational imaging, augmented and virtual reality, automotive, display, biosensing, nonlinear, quantum and topological optics, optical computing, and more. At the same time, the ability of metasurfaces to perform optical functions in much more compact optical systems has triggered strong and constantly growing interest from various industries that greatly benefit from the availability of miniaturized, highly functional, and efficient optical components that can be integrated in optoelectronic systems at low cost. This creates a truly unique opportunity for the field of metasurfaces to make both a scientific and an industrial impact. Furthermore, the goal of this Roadmap is to mark this “golden age” of metasurface research and define future directions to encourage scientists and engineers to drive research and development in the field of metasurfaces toward both scientific excellence and broad industrial adoption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric waves and global seismoacoustic observations of the January 2022 Hunga eruption, Tonga

The 15 January 2022 climactic eruption of Hunga volcano, Tonga, produced an explosion in the atmosphere of a size that has not been documented in the modern geophysical record. The event generated a broad range of atmospheric waves observed globally by various ground-based and spaceborne instrumentation networks. Most prominent was the surface-guided Lamb wave (≲0.01 hertz), which we observed propagating for four (plus three antipodal) passages around Earth over 6 days. As measured by the Lamb wave amplitudes, the climactic Hunga explosion was comparable in size to that of the 1883 Krakatau eruption. The Hunga eruption produced remarkable globally detected infrasound (0.01 to 20 hertz), long-range (~10,000 kilometers) audible sound, and ionospheric perturbations. Seismometers worldwide recorded pure seismic and air-to-ground coupled waves. Air-to-sea coupling likely contributed to fast-arriving tsunamis. In this article, we highlight exceptional observations of the atmospheric waves.

58 GEOSCIENCES↗

Illuminating the North Korean nuclear explosion test in 2017 using remote infrasound observations

North Korea conducted its sixth underground nuclear explosion test (mb 6.3) on 2017 September 3. The underground explosion produced substantial low-frequency atmospheric waves, which were detected by infrasound arrays located up to a distance of 566 km. These infrasound waves are formed by the conversion of seismic energy to acoustic energy across the lithosphere–atmosphere interface. While infrasound records at regional distances produce estimates of ground motion amplitude over spatially extended regions covering about 26 500 km 2 , 3-D full seismo-acoustic simulations within the lithosphere and atmosphere provide quantitative information about seismo-acoustic energy partitioning. Our results demonstrate the capability of remote infrasound observations combined with 3-D propagation modelling to further develop discrimination methods for underground sources. These results contribute to enhance the confidence of source identification and characterization in nuclear test monitoring research, which is essential for the enforcement of the Comprehensive Nuclear-Test-Ban Treaty.

58 GEOSCIENCES↗

Inhibitory effect of celastrol on adipogenic differentiation of human adipose-derived stem cells

Highlights: • Celastrol has therapeutic potential against obesity- and aging-related diseases. • Anti-adipogenic effect of celatrol in human ADSCs depended on dose and duration. • Celatrol inhibited adipogenesis in human ADSCs by regulating PPARG and CEBPA. • Celastrol inhibited adipogenesis in hADSCs derived from 12 donors with various ages. • Celastrol also inhibited osteogenic and chondrogenic differentiation in hADSCs. Control of adipogenesis in mesenchymal stem cells (MSCs) offers enormous potential for management of obesity- and aging-related diseases. Celastrol, the traditional Chinese medicine extracted from Tripterygium wilfordi, exhibits anti-obesity effects in in vitro and in vivo murine models. This study describes how celastrol affects multilineage differentiation potential of human adipose-derived stem cells (hADSCs). We performed in vitro adipogenic differentiation of hADSCs and investigated how celastrol-induced lipid accumulation and expression of adipocyte differentiation markers varied with dose, duration, and donor age. In addition, we assessed the effect of celastrol on osteogenic and chondrogenic differentiation of hADSCs. During adipogenic induction of hADSCs, the inhibitory effect of celastrol on lipid accumulation and adipogenesis depended on dose, duration, time of administration, and individual donor. Inhibition was mediated by proliferator-activated receptor-γ (PPARG) and CCAAT/enhancer-binding protein alpha (CEBPA). Celastrol also suppressed differentiation of hADSCs into the osteogenic and chondrogenic lineages. Celastrol plays a regulatory role in multilineage differentiation of human MSCs. Our findings provide important insights regarding management of obesity and stem cell therapy.

60 APPLIED LIFE SCIENCES↗

Dynamic thermal emission control with InAs-based plasmonic metasurfaces

Thermal emission from objects tends to be spectrally broadband, unpolarized, and temporally invariant. These common notions are now challenged with the emergence of new nanophotonic structures and concepts that afford on-demand, active manipulation of the thermal emission process. This opens a myriad of new applications in chemistry, health care, thermal management, imaging, sensing, and spectroscopy. Here, we theoretically propose and experimentally demonstrate a new approach to actively tailor thermal emission with a reflective, plasmonic metasurface in which the active material and reflector element are epitaxially grown, high-carrier-mobility InAs layers. Electrical gating induces changes in the charge carrier density of the active InAs layer that are translated into large changes in the optical absorption and thermal emission from metasurface. We demonstrate polarization-dependent and electrically controlled emissivity changes of 3.6%P (6.5% in relative scale) in the mid-infrared spectral range.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characteristics of infrasound signals from North Korean underground nuclear explosions on 2016 January 6 and September 9

This study investigates infrasound signals from North Korean underground nuclear explosions on 2016 January 6 at 01:30:01 UTC (UNEJ16) and on 2016 September 9 at 00:30:01 UTC (UNES16). Infrasound observations from eight, seismo-acoustic arrays at distances of 300–600 km from the explosions and aligned approximately east–west across South Korea are used in the analysis. Progressive multichannel correlation was used followed by analyst review to identify the infrasound arrivals with estimates of azimuth, phase velocity, celerity, F-statistic, signal-to-noise ratio, correlation and signal duration. These observations are compared with model predictions of travel path, ray turning height and relative amplitudes, using Ground-to-Space atmospheric specifications at the time of each explosion. Stratospheric conditions at the time of the UNEJ16 are favourable to the Korean arrays when all arrays detected infrasound signals, while the few detections for UNES16 are consistent with unfavourable stratospheric winds and reduced amplitude thermospheric arrivals. Infrasound locations of the explosions were estimated using the Bayesian Infrasonic Source Location method (BISL), with wind-corrected backazimuth estimates based on the ray tracing calculations. Adding wind corrections to BISL resulted in infrasound locations up to 50 per cent closer to the seismic epicentre over uncorrected locations. The UNES16 infrasound location estimate using atmospheric corrections had larger differences (~67 km difference from seismic location) than the UNEJ16 location (~11 km difference from seismic location) as a result of the reduced number of observations and poor azimuth coverage for UNES16. Based on stratospheric phases recorded at six arrays and the empirical yield-scaling relations, wind corrected amplitudes from UNEJ16 lead to equivalent infrasound source energy estimates between 0.9 and 16.1 tons of TNT detonated in the atmosphere with an average of 6.4 tons and a standard deviation of 4.6 tons.

58 GEOSCIENCES↗

Tuning of Plasmons in Transparent Conductive Oxides by Carrier Accumulation

A metal naturally displays dramatic changes in its optical properties near the plasma frequency where the permittivity changes from a negative to a positive value, and the material turns from highly reflective to transparent. For many applications, it is desirable to achieve such large optical changes by electrical gating. However, this is challenging given the high carrier density of most metals, which causes them to effectively screen externally applied electrical fields. Indium tin oxide (ITO) is a low-electron-density metal that does afford electric tuning of its permittivity in the infrared spectral range. In this paper, we experimentally show the tunability of the plasma frequency of an ITO thin film by changing its sheet carrier density via gating with an ionic liquid. By applying moderate gate bias values up to 1.4 V, the electron density increases in a thin (~3 nm) accumulation layer at the surface of the 15-nm-thick ITO film. This results in notable blue shifts in the plasma frequency. These optical and electrical changes are monitored simultaneously, which facilitates construction of a model that provides a consistent picture for the dc electrical and infrared optical properties. It can be used to quantitatively predict the optical changes in the ITO layer with applied bias. Finally, this work builds our understanding of electrically tunable plasmonic materials and aids the design of ultracompact, active nanophotonic elements.

36 MATERIALS SCIENCE↗

Electrical tuning of a quantum plasmonic resonance

Surface plasmon (SP) excitations in metals facilitate confinement of light into deep-subwavelength volumes and can induce strong light–matter interaction. Generally, the SP resonances supported by noble metal nanostructures are explained well by classical models, at least until the nanostructure size is decreased to a few nanometres, approaching the Fermi wavelength λ F of the electrons. Although there is a long history of reports on quantum size effects in the plasmonic response of nanometre-sized metal particles systematic experimental studies have been hindered by inhomogeneous broadening in ensemble measurements, as well as imperfect control over size, shape, faceting, surface reconstructions, contamination, charging effects and surface roughness in single-particle measurements. In particular, observation of the quantum size effect in metallic films and its tuning with thickness has been challenging as they only confine carriers in one direction. Here, we show active tuning of quantum size effects in SP resonances supported by a 20-nm-thick metallic film of indium tin oxide (ITO), a plasmonic material serving as a low-carrier-density Drude metal. An ionic liquid (IL) is used to electrically gate and partially deplete the ITO layer. The experiment shows a controllable and reversible blue-shift in the SP resonance above a critical voltage. As a result, a quantum-mechanical model including the quantum size effect reproduces the experimental results, whereas a classical model only predicts a red shift.

36 MATERIALS SCIENCE↗

Detection of regional infrasound signals using array data: Testing, tuning, and physical interpretation

This work quantifies the physical characteristics of infrasound signal and noise, assesses their temporal variations, and determines the degree to which these effects can be predicted by time-varying atmospheric models to estimate array and network performance. An automated detector that accounts for both correlated and uncorrelated noise is applied to infrasound data from three seismo-acoustic arrays in South Korea (BRDAR, CHNAR, and KSGAR), cooperatively operated by Korea Institute of Geoscience and Mineral Resources (KIGAM) and Southern Methodist University (SMU). Arrays located on an island and near the coast have higher noise power, consistent with both higher wind speeds and seasonably variable ocean wave contributions. On the basis of the adaptive F-detector quantification of time variable environmental effects, the time-dependent scaling variable is shown to be dependent on both weather conditions and local site effects. Significant seasonal variations in infrasound detections including daily time of occurrence, detection numbers, and phase velocity/azimuth estimates are documented. These time-dependent effects are strongly correlated with atmospheric winds and temperatures and are predicted by available atmospheric specifications. As a result, this suggests that commonly available atmospheric specifications can be used to predict both station and network detection performance, and an appropriate forward model improves location capabilities as a function of time.

47 OTHER INSTRUMENTATION↗

Superabsorbing, Artificial Metal Films Constructed from Semiconductor Nanoantennas

In 1934, Wilhelm Woltersdorff demonstrated that the absorption of light in an ultrathin, freestanding film is fundamentally limited to 50%. He concluded that reaching this limit would require a film with a real-valued sheet resistance that is exactly equal to R = η/2 ≈ 188.5Ω/$\square$, where η=√μ 0 /ϵ 0 is the impedance of free space. This condition can be closely approximated over a wide frequency range in metals that feature a large imaginary relative permittivity ε r ", that is, a real-valued conductivity σ = ε 0 ε r "ω. A thin, continuous sheet of semiconductor material does not facilitate such strong absorption as its complex-valued permittivity with both large real and imaginary components preclude effective impedance matching. Here, we show how a semiconductor metafilm constructed from optically resonant semiconductor nanostructures can be created whose optical response mimics that of a metallic sheet. Because of this reason, the fundamental absorption limit mentioned above can also be reached with semiconductor materials, opening up new opportunities for the design of ultrathin optoelectronic and light harvesting devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Comparative Study of Automated Infrasound Detectors - PMCC and AFD with Analyst Review.

Automated detections calculated by the progressive multi-channel correlation (PMCC) method (Cansi, 1995) and the adaptive F detector (AFD) (Arrowsmith et al., 2009) are compared to the signals identified by five independent analysts. Each detector was applied to a four-hour time sequence recorded by the Korean infrasound array CHNAR. This array was used because it is composed of both small (<100 m) and large (~1000 m) aperture element spacing. The four hour time sequence contained a number of easily identified signals under noise conditions that have average RMS amplitudes varied from 1.2 to 4.5 mPa (1 to 5 Hz), estimated with running five-minute window. The effectiveness of the detectors was estimated for the small aperture, large aperture, small aperture combined with the large aperture, and full array. The full and combined arrays performed the best for AFD under all noise conditions while the large aperture array had the poorest performance for both detectors. PMCC produced similar results as AFD under the lower noise conditions, but did not produce as dramatic an increase in detections using the full and combined arrays. Both automated detectors and the analysts produced a decrease in detections under the higher noise conditions. Comparing the detection probabilities with Estimated Receiver Operating Characteristic (EROC) curves we found that the smaller value of consistency for PMCC and the larger p-value for AFD had the highest detection probability. These parameters produced greater changes in detection probability than estimates of the false alarm rate. The detection probability was impacted the most by noise level, with low noise (average RMS amplitude of 1.7 mPa) having an average detection probability of ~40% and high noise (average RMS amplitude of 2.9 mPa) average detection probability of ~23%.

58 GEOSCIENCES↗