Image-based tracking system for vibration measurement of a rotating object using a laser scanning vibrometer

An image-based tracking system using laser scanning vibrometer is developed for vibration measurement of a rotating object. The proposed system unlike a conventional one can be used where the position or velocity sensor such as an encoder cannot be attached to an object. An image processing algorithm is introduced to detect a landmark and laser beam based on their colors. Then, through using feedback control system, the laser beam can track a rotating object.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Note: Optical and electronic design of an amplitude-modulated continuous-wave laser scanner for high-accuracy distance measurement

To utilize a time-of-flight-based laser scanner as a distance measurement sensor, the measurable distance and accuracy are the most important performance parameters to consider. For these purposes, the optical system and electronic signal processing of the laser scanner should be optimally designed in order to reduce a distance error caused by the optical crosstalk and wide dynamic range input. Optical system design for removing optical crosstalk problem is proposed in this work. Intensity control is also considered to solve the problem of a phase-shift variation in the signal processing circuit caused by object reflectivity. The experimental results for optical system and signal processing design are performed using 3D measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced method to reconstruct mode shapes of continuous scanning measurements using the Hilbert Huang transform and the modal analysis method

Generally, it is time consuming to experimentally identify the operating deflection shape or mode shape of a structure. To overcome this problem, the Hilbert Huang transform (HHT) technique has been recently proposed. This technique is used to extract the mode shape from measurements that continuously measure the vibration of a region of interest within a structure using a non-contact laser sensor. In previous research regarding the HHT, two technical processes were needed to obtain the mode shape for each mode. The purpose of this study is to improve and complement our previous research, and for this purpose, a modal analysis approach is adapted without using the two technical processes to obtain an accurate un-damped impulse response of each mode for continuous scanning measurements. In addition, frequency response functions for each type of beam are derived, making it possible to make continuously scanned measurements along a straight profile. In this paper, the technical limitations and drawbacks of the damping compensation technique used in previous research are identified. In addition, the separation of resonant frequency (the Doppler effect) that occurs in continuous scanning measurements and the separation of damping phenomenon are also observed. The proposed method is quantitatively verified by comparing it with the results obtained from a conventional approach to estimate the mode shape with an impulse response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic force driven six degree-of-freedom active vibration isolation system using a phase compensated velocity sensor

A six-axis active vibration isolation system (AVIS) is developed using voice coil actuators. Point contact configuration is employed to have an easy assembly of eight voice coil actuators to an upper and a base plates. The velocity sensor, using an electromagnetic principle that is commonly used in the vibration control, is investigated since its phase lead characteristic causes an instability problem for a low frequency vibration. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system using the atomic force microscope images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional shape optical measurement using constant gap control and error compensation

The optical laser displacement sensor is widely used for noncontact measurement of the three-dimensional (3D) shape profile of the object surface. When the surface of an object has a slope variation, the sensor gain is proportionally varied according to that of the object surface. In order to solve the sensor gain variation problem, the constant gap control method is applied to adjust the gap to the nominal distance. Control error compensation is also proposed to cope with the situation even when the gap is not perfectly controlled to the nominal distance using an additional sensor attached to the actuator. 3D shape measurement applying the proposed constant gap control method shows better performances rather than the constant sensor height method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗