Search NASA⌕ Search

Engineering topics

Parker Jr., Gary Robert

Publications and source records attributed to Parker Jr., Gary Robert.

Standardizing an Intermediate-Scale High Explosive Safety Test Suite

Small-scale safety testing, while successful in screening out extremely dangerous explosive compositions, does not fully characterize the explosive hazards associated with handling larger, consolidated or bare charges. It is proposed that intermediate-scale tests using consolidated charges in the range 25 mg – 1 kg are warranted to satisfactorily address the hazards. A standard for this intermediate-scale testing should be developed, proofed, peer-reviewed and adopted to assist in the development of safe new high explosive compositions across the complex. This whitepaper explains why current small-scale safety testing is insufficient to characterize the handling hazard, identifies the guiding aspects of explosive response that drive the handling hazards associated with larger consolidated charges, and proposes a suite of tests/experiments that can serve as a starting point for an intermediate-scale safety standard.

42 ENGINEERING↗

IHE DDT Qualification Tests (FY2020-FY2021)

A DDT tube test was designed to meet all requirements established in the new DOE IHE qualification standard. Ten tests were successfully executed with PBX 9502 as a demonstration of the design, assembly, heating system, and methods, and to establish a baseline set of test results with an existing IHE. The explosive response in all tests was low violence (as anticipated). This report contains detailed design drawings, assembly instructions and procedures for future execution of the qualification test series, and makes recommendations for minor improvements.

42 ENGINEERING↗

CISME report on experiments with HMX powder, PBX 9501 prills, and heated PBX 9501

The ability to predict post-ignition explosive response is relevant to explosives safety, particularly weapons assembly/disassembly operations that must operate under a sufficiently conservative safety basis to meet risk mitigation criteria for inadvertent nuclear detonation (IND). In particular, hazard determinations hinge on whether the PBX 9501 main charge can ultimately attain detonation from an initial, non-shock, ignition stimulus. The CISME experiment uses a spherical explosive charge, which is thermally ignited in the center using a fiber-delivered infrared laser pulse. This ignition mechanism - i.e. a localized thermal hotspot - is representative of the ignition-causing insults typical in accident scenarios, including low-velocity impact, drop, skid, and punch events. In fiscal year 2018 CISME experiments were conducted with pristine PBX 9501 spheres, confined and unconfined. Sub-detonative, low-violence reactions were observed. Here we report experiments conducted since 2018. The explosive charge was varied: experiments were conducted with room temperature pour-density HMX powder and prills of PBX 9501, and heated, thermally damaged PBX 9501. Experiments were conducted in a confined configuration, with two 4 mm-thick stainless-steel hemispherical shells bolted around the sphere. Detonation, via DDT (deflagration-to-detonation transition) was observed in the 3-inch diameter powdered HMX and the 6-inch diameter heated and thermally-damaged PBX 9501 tests. No transition to DDT was observed in smaller diameters for those configurations, and no DDT was observed for pour-density prills of PBX 9501 of any diameter. The original test series demonstrated that the response of pristine, undamaged PBX 9501 to a central ignition is relatively benign. This new test series shows that increased porosity, lack of polymer binders and thermal damage can greatly increase the violence of the post-ignition response, up to and including detonation. These results bridge the explosive response of PBX 9501 from sub-detonative through detonation as a function of diameter and provide valuable test cases for modeling efforts that strive to capture the DDT threshold. By exploring explosive response in a more representative 3D geometry, we can also benchmark these new results to more plentiful DDT datasets generated from testing in 1D tube confinement (the historical test configuration)–the configuration upon which almost all DDT models were developed.

42 ENGINEERING↗

Slide Test FY 2019 Report

At Los Alamos, the Slide Test was developed in 2019 to investigate whether the mass of a main charge of explosive sliding on a gritty surface, in the absence of impact, is sufficient to heat grit to ignition temperatures in PBX 9501. This is a practical test to address frictional ignition during assembly/disassembly operations at the Pantex Plant. Twenty-seven Slide Tests were performed in total, testing PBX 9501 at various slide velocities, grit diameters, grit patterns, and charge masses. Time-resolved velocimetry of the slide event (from PDV) and spot area of the explosive charge (obtained from image analysis) is reported. High-speed videography is used to diagnose explosive reaction. Eighteen of these tests were performed with a charge mass of 30 lbs at velocities ≤ 4 m s-1 and grit diameters between 75 and 1000 µm. Nine Slide Tests were performed with a 15 lb charge mass at similar parameters. No ignition was observed in any of the tests. These data provide evidence that the mass of a main charge, caused to slide on a surface at the low velocities achievable during routine handling, is insufficient stimulus to heat grit to ignition temperatures. These findings are relevant to risk assessment for explosive handling operations and provide evidence that PBX 9501 is safe within the constraints that were tested. However, because ignitions were not observed in any of the tests, we cannot determine which variables (mass or velocity) dominate the explosive response and to what extent. The absence of observed ignition also precludes the determination of a safety margin. To identify this safety margin, further research would be necessary to define the velocity and/or mass threshold at which ignition occurs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Case Penetration and Detonator Crush FY2019 Report

The Punch Gun apparatus delivers a low-velocity, high-momentum impact that is representative of potential human accident insults, including drops, trips, and falls. This apparatus has been used since 2016 to explore various accident scenarios of interest to weapons handling operations. In previous years, ignition and violent deflagration of heavily confined cased charges of PBX 9501 was observed at very low velocities (~1.5 m s-1) with pointed tips. Ignition followed by violent deflagration was also observed with blunt impacts of un-cased bare charges of LX-07 and LX-07 with an embedded detonator. Previously, no ignition was observed with blunt impacts of bare charges of PBX 9501.

42 ENGINEERING↗