Microcracking in Composite Laminates: Simulation of Crack-Induced Ultrasound Attenuation

Microcracking in composite laminates is a known precursor to the growth of inter-ply delaminations and larger scale damage. Microcracking can lead to the attenuation of ultrasonic waves due to the crack-induced scattering. 3D elastodynamic finite integration technique (EFIT) has been implemented to explore the scattering of ultrasonic waves due to microcracks in anisotropic composite laminates. X-ray microfocus computed tomography data was directly input into the EFIT simulation for these purposes. The validated anisotropic 3D EFIT code is shown to be a useful tool for exploring the complex multiple-scattering which arises from extensive microcracking.

Leckey, C. A. C.↗

Measurement of the degree of cure in epoxies with ultrasonic velocity

The use of ultrasonic longitudinal velocity values to measure the degree of cure (defined for an epoxide system as the concentration of epoxide/amine bonds divided by the initial epoxide concentration) in epoxy resins is investigated. The experimental setup used to measure the changes in longitudinal velocity with time is described, together with the technique used to calculate the degree of cure from the acoustic data, using the principle of additive module. Measurements were done with diglycidyl ether of bisphenol A epoxy resin cured with an amine adduct agent. Good qualitative agreement was shown between the time dependence of the acoustically measured degree of cure and the predicted rate of reaction.

Winfree, W. P.↗

Acoustic characterization of composite cure

The relationship between the time evolution of ultrasonic longitudinal velocities, measured in the course of the cure of 3501-6 neat and fiber-reinforced resin, and the time evolution of the degree of cure was studied. The resin samples were placed in a mold, one side of which was a graphite plate, while the rest was made of stainless steel. After placing the mold in a press and applying a single-cycle 5-MHz pulse to the transducer bonded to the outer side of the graphite plate, the echo resulting from the resin-graphite interface and the subsequent echoes from within the resin layer were recorded with a 200-MHz, 8-bit digitizer. The degree of cure was calculated from the acoustic response, using the relationships derived by Winfree and Parker (1986). The calculated degree of cure had the expected time dependence, and the agreement between the degree of cure measured for the neat resin and the prepreg was reasonable.

Parker, F. R.↗

Ultrasonic characterization of changes in viscoelastic properties of epoxy during cure

A technique for using the longitudinal velocity (LV) of an ultrasonic wave to monitor the extent of cross linking (CL) during the cure of thermosetting resins is described. The method was developed by monitoring the rate of change in LV during the cure of a bisphenol-A epoxy resin with an amine adduct. The experiment included variations in the temperature and stoichiometry in order to express the rate of change in terms of the reaction kinetics. The pulse-echo method was used with a single transducer operating at 20 MHz. Numerical models were defined to account for the acoustic response of a single layer, the attenuation and the reflection coefficient. A linear relationship was observed between the inverse of the temperature and the log of the rate of change in the velocity, supporting the theory that the velocity could be used to monitor the extent of the cross-linking reaction. An activation energy of 11.9 kcal/mole was calculated for the mixture being investigated.

Winfree, W. P.↗