Fast-airflow tumble clothes dryer with small thermoelectric heat pump: Experimental evaluation

Residential clothes drying accounts for about 5% of the total residential-sector energy consumption in the United States. Most dryers use electric resistance heaters to dry clothes and have low efficiencies. Higher-efficiency dryers that use vapor compression heat pumps are expensive and complex and have not gained a large market share in the United States. A novel tumble clothes dryer using a small thermoelectric heat pump with faster airflow than typical dryers is presented in this work. The benchtop performance of the thermoelectric heat pump and high-speed blower are presented, and the development of the prototype dryer is described. The dryer was tested for efficiency and dry time for a range of airflow rates and applied currents to the thermoelectric heat pump. The combined efficiency factor was 5.09–6.29 lb BDW /kWh (specific moisture extraction rate of 1.23–1.53 kg w /kWh) with 100–138 min dry times for these tests. The measured efficiency was 36 %–68 % greater than the minimum efficiency standard in the United States, and compared with vapor compression heat pump–based clothes dryers, the prototype dryer had less expensive, less complex components and did not use refrigerants. Finally, the performance of this small thermoelectric heat pump clothes dryer is also compared with previous iterations of the thermoelectric tumble clothes dryer described in the literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Recovery System for Domestic Dishwashers (Final Report)

The objectives of this project were to enable commercialization of a patent-pending technology for unprecedented dishwasher energy savings and non-energy consumer benefits. Specific objectives were to (1) provide customer-requested features of more thorough drying, (2) reduce kitchen humidity load (75% target reduction in water vapor released by the dishwasher), (3) introduce the lowest energy consumption domestic dishwasher on the market with 30% less energy consumption than that of the current best in market, and (4) maintain high cleaning performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Carnot Analysis of Heat Pump Drying: Ideal Efficiency and Dry Time

Drying processes are important in appliances and in industry, and clothes drying accounts for approximately 3% of residential primary energy consumption in the US. Globally, heat pump tumble dryers (HPD) are increasing their market share against the ubiquitous electric resistance tumble dryer (ERD). In this work, efficiency and dry time limits are defined for ideal HPDs, for both closed air cycle (unvented) and open air cycle (vented). These limits are compared with the limits for ERD. The traditional Carnot efficiency limit for an ideal heat pump, operating between a hot and a cold thermal reservoir, does not apply directly to clothes dryers. One reason dryers require a novel analysis is the presence of additional degrees of freedom, since the hot and cold temperatures are floating, unfixed by ambient conditions. Furthermore, dryers can operate in a closed or open air cycle, and each requires a different analysis. In the closed (unvented) case, the hot and cold temperatures are coupled to each other; while in the open (vented) case, the hot and cold temperatures are both independent free variables. This paper provides an analysis of the fundamental efficiency limits of ERDs and HPDs, which can inform the design and performance limits of evaporative drying technology.

Gluesenkamp, Kyle↗

Experimental results of a magnetically coupled piezoelectric actuator to relieve microchannel heat exchanger maldistribution

Refrigerant maldistribution is a common issue in microchannel heat exchangers. Refrigerant maldistribution can have significant negative effects on the heat transfer performance and increase the pressure drop, leading to increased superheat temperature at the outlet and increased compressor work, lowering system efficiency. In this work, a novel piezoelectric-driven magnetic actuator (PEDMA) was fabricated and inserted into the inlet header of the microchannel evaporator, with the goal of improving the non-uniformity of the flow distribution by regulating the flow in the header to the microchannels. Two prototype PEDMA designs were tested and showed significant impact on the refrigerant flow in the region of actuation. In the first design, the experimental data showed superheat reductions up to 9 °C when the individual channel temperatures were measured. The second design redistributed the refrigerant such that a 1% increase in capacity was calculated for the whole heat exchanger without significantly impacting the heating efficiency. The experimental results demonstrate the successful operation of the PEDMA devices and represent a new method of active flow distribution control which is based on a simple design with minimal additional energy consumption, and which can be inserted into microchannel heat exchanger headers to potentially relieve the refrigerant maldistribution.

42 ENGINEERING↗

Efficiency Limits of Evaporative Fabric Drying Methods

Cloth drying is a major consumer of energy, and most drying is conducted by evaporative methods. The evaporative drying energy efficiency limit is commonly assumed to be 100%: one unit of latent heat removed per unit of energy expended. However, this ignores the “free drying” available from unsaturated ambient air and the possible role of heat pumping. We demonstrate that efficiency limits for evaporative drying are fundamentally related to both drying rate and ambient psychrometric conditions. A relationship among efficiency, drying rate, and ambient conditions is quantified for several evaporative drying technologies, and a comparison among evaporative technologies is provided. In addition, a comparison is provided between efficiency limits and state of the art device performance. This research will help guide future research in the most promising directions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Dehumidification using Ionic Liquid-Based Fiber Bundle Membrane Contactor

Air dehumidification is essential since excess moisture in the buildings causes discomfort to the occupants, encourages the production of air pathogens such as mold or mildew, and causes corrosion and rotting that degrade building materials. Existing moisture removal processes are mainly focused on condensation and desiccant (liquid or solid) techniques with direct contact between air and desiccant. However, these methods are energy-intensive, or desiccant might be lost or cause corrosion in the process. The main objective of this study is to investigate an ionic liquid-based liquid desiccant absorber based on a membrane fiber bundle. The novel system consists of membrane contactors containing bundles of 10,000 polypropylene fibers. The fiber bundles have 0.3 micron diameter, with ionic liquid flowing inside, and air flowing outside. The fibers provide a high contact area among phases: 1.4 m2 contact surface area in a 0.00015 m3 volume. The ionic liquid as a sorbent stipulates the selectivity for air, prevents the loss of solvent in the operation due to negligible volatility, provides fast diffusion due to low viscosity compared to common ionic liquids, and has high affinity and solubility in water. The dehumidification capacity of the membrane technology was experimentally investigated. The experimental results show that the ionic-liquid based membrane system can effectively remove excess moisture from the air. The novel fiber bundle dehumidification system has a system volume of 0.00798 m3 (7.98 L) and active heat and mass transfer surface area of 8.4 m2. It achieved an average dehumidification of 320 ± 25 W with a volumetric air flowrate of 3.1 m3/min (108 ft3/min).

Turnaoglu, Tugba↗

Reduced-order model to estimate safe flammable refrigerant charge limits for a one-room air conditioner

The Heating, Ventilation, Air-Conditioning and Refrigeration (HVAC&R) industry is currently transitioning away from high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants. However, many lower-GWP alternatives are flammable. Current safety codes restrict use of all flammable refrigerants; revision of the codes is needed to facilitate wider use of flammable alternatives. Hence, information is needed to enable reliable estimates of safe charge limits for flammable refrigerant options for different HVAC&R applications. A reduced-order model (ROM) was developed and validated to help estimate safe charge limits based on computational fluid dynamics (CFD) simulations of refrigerant releases in a single room for a range of parameters. Validation of the ROM vs. the CFD results showed good general agreement for mean refrigerant concentration. The normalized mean bias error (NMBE) was 0.67% with a maximum error of 15%.

Edwards, Dean↗

Characteristics of refrigerant leaks from small HVAC&R systems

Reduced use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants is desired. However, many lower-GWP alternatives are flammable, some of higher flammability levels, or A3, and others of lower flammability (A2 or A2L).Safety standards for A2 and A3 flammable refrigerants, including the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 calculate maximum flammable refrigerant charge limits using a fixed 4-minute leak time based on the time to leak 150 g of CO2 through a capillary tube.Actual refrigerant leak times depend on the equipment type, leak location, leak orifice diameter and equipment operation condition (on or off).Five systems were installed in test chambers with leak quantities and rates measured by tracking total system weight during the leak event. Among the major results were that almost all of the system charge was shown to escape the units, >80% within the first 10 minutes.

Patel, Viral↗

Non-Contact Ultrasonic Drying Technology for Drying Owens Corning Dry-Use Fiberglass (CRADA Final Report)

In this collaborative research project between ORNL and the Composites Division of Owens Corning (a world leader in the production of glass-fiber reinforcement materials), non-contact ultrasonic drying was studied as a way to enhance the drying of Dry-Use Fiberglass Products. Current methods of drying fiberglass products utilize traditional convection ovens with relatively low efficiency. Enhancing the drying process through the use of different techniques is highly desirable to reduce the overall energy consumption attributed to drying.

36 MATERIALS SCIENCE↗

Ultrasonic Piezoelectric Atomizers: Electromechanical Modeling and Performance Testing

Ultrasonic atomization of bulk liquids has received extensive attention in the past few decades due to the ability to produce controlled droplet sizes, a necessity for many industries such as spray coating and aerosol drug delivery. Despite the increase in attention, one novel application of this technology has been overlooked until recently, and that is the moisture removal capabilities of atomization. The first ever ultrasonic dryer, created by researchers at Oak Ridge National Lab in 2016, applies the mechanisms of atomization to mechanically remove moisture from clothing. The process utilizes the ultrasonic vibrations created by a piezoelectric transducer in direct contact with a wet fabric to rupture the liquid-vapor boundary of the retained water. Once ruptured, smaller droplets are ejected from the bulk liquid and are actively removed from the fabric pores. The mechanisms of droplet ejection from this event are related to both capillary waves forming on the liquid surface (Capillary Wave Theory), as well as the implosion of cavitation bubbles formed from the hydraulic shocks propagating from the transducer (Cavitation Theory). In this work, we present an analytical model for predicting the moisture removal rate of a wet fabric exposed to ultrasonic vibrations, and connect the atomization events to a global variable, acceleration, in order to decouple the nondeterministic relationship between the transducer and applied voltage. The acceleration governing atomization is predicted using a verified numerical model. The numerical model is shown to assist in developing ultrasonic drying by means of efficiently evaluating transducer design changes.