Search NASA⌕ Search

Engineering topics

Paul, Donald R.

Publications and source records attributed to Paul, Donald R..

Thermally-rearranged polymer blends for gas separation membranes

Polymer blends comprising an ortho-functionalized polyimide homo or copolymer and a polybenzimidazole homo or copolymer, wherein the ortho-functionalized polyimide thermally rearranges to a polymer comprising a phenylene heterocyclic group, such as, polybenzoxazole, polybenzothiazole, polybenzimidazole and/or other heterocyclic structure upon heating. Also disclosed are method of forming a polymer blend comprising dissolving an ortho-functionalized polyimide homo or copolymer and a polybenzimidazole homo or copolymer in a solvent, and optional compatibilizer, to form a polymer solution; contacting a support with the polymer solution; and evaporating the solvent to provide a thin layer comprising the polymer blend on the support. Further, methods of heat treating these polymer blends to thermally rearrange the disclosed polyimides are disclosed, as are the polymer blends prepared thereby. Methods of using these polymer blends to separate gases are also disclosed.

Freeman, Benny D.↗

Salt and ion transport in a series of crosslinked AMPS/PEGDA hydrogel membranes

Salt permeability and ionic conductivity are critical properties for membranes in water purification and energy applications. Both properties depend on individual ion sorption and diffusion coefficients, which are significantly influenced by polymer chemical and physical parameters such as fixed charge concentration and membrane water content. However, systematic studies connecting polymer structure to ion transport properties are still lacking. In this study, a series of uncharged and charged membranes were synthesized using poly(ethylene glycol) diacrylate (PEGDA) as a cross-linker and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPS) as a charged monomer. Membrane fixed charge concentration and water uptake were systematically varied by adjusting AMPS content in the pre-polymerization mixture. Salt sorption and permeability coefficients and ionic conductivity of these membranes were measured as a function of NaCl solution concentration (0.01–1 M). Combining the solution-diffusion model and Nernst-Planck equation, individual ion diffusion coefficients were calculated. Experimental Na + diffusion coefficients for all materials were well described by the Mackie and Meares tortuosity model, highlighting the strong influence of water content on ion diffusivity in both uncharged and charged polymers. Model predictions for Cl – diffusion coefficients agree reasonably well with experimental values, with some deviations occurring in more highly charged membranes. Finally, this discrepancy might result from interactions not captured by the Mackie and Meares model (e.g., fixed charge-ion interactions).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of fixed charge concentration and water uptake on ion sorption in AMPS/PEGDA membranes

Water content and charge density strongly influence ion sorption in charged membranes. However, isolating the individual effect of each parameter on ion sorption can be difficult due to experimental challenges associated with independently controlling these two variables during membrane synthesis. This frustrates development and validation of fundamental models and structure/property relationships. In this study, three series of uncharged and negatively charged hydrogel membranes were prepared using poly(ethylene glycol) diacrylate (PEGDA) as a cross-linker and 2-acrylamido-2-methylpropanesulfonic acid (AMPS) as an ionic monomer. Here, water content and charge density were controlled by varying AMPS content and PEGDA chain length. Ion sorption in these materials was measured using aqueous NaCl solutions at concentrations ranging from 0.01 to 1.0 M. At constant charge density, salt sorption increased as water content increased. At fixed water content, salt sorption decreased as charge density increased. Salt sorption in membranes with the highest water content and charge density was predicted using the Donnan/Manning model, which accounts for solution and membrane phase thermodynamic non-idealities. However, this approach could not predict sorption in weakly charged and uncharged membranes, presumably due to additional membrane phase thermodynamic non-idealities associated with ion solvation and uncharged polymer segments.

36 MATERIALS SCIENCE↗

Pure- and mixed-gas transport properties of a microporous Tröger's Base polymer (PIM-EA-TB)

Polymers of intrinsic microporosity (PIMs) offer tantalizing combinations of high selectivity and permeability in initial gas permeation measurements. Here, we report characterization of pure- and mixed-gas permeation properties of a thick (~80 μm) PIM consisting of Tröger's Base (TB) and Ethanoanthracene (EA) films. The effects of feed pressure and temperature on pure-gas permeabilities of CH 4 , N 2 , O 2 , H 2 , and CO 2 were investigated. The physical aging behavior of the thick film was tracked via pure-gas O 2 , N 2 , and CH 4 permeability at 35 °C. Gas permeability decreased noticeably and selectivity increased as aging time increased. Particular attention was given to mixed-gas measurements of CO 2 and CH 4 (50/50) permeabilities at 35 °C and fugacities ranging from 2 to 18 atm to explore whether the rigid, bridged, bicyclic TB and EA units could resist CO 2 -induced plasticization. These results are presented along with pure-gas CO 2 and CH 4 results for membrane samples aged at different times. PIM-EA-TB aged for ~24 h did not show signs of plasticization across the fugacity range considered. Furthermore, dual-mode competitive sorption presumably caused the CO 2 /CH 4 mixed-gas selectivity to be slightly higher than its corresponding pure-gas selectivity. However, as aging time increased, aged films underwent progressively more rapid and extensive CO 2 -induced plasticization with increasing fugacity, suggesting a systematic relationship between physical aging and plasticization in PIMs. Consequently, physical aging caused less improvement in mixed-gas CO 2 /CH 4 selectivity than it did in pure-gas selectivity, due mainly to plasticization effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of humidity on gas transport in polybenzimidazole membranes

Polybenzimidazoles (PBIs) are promising materials for high temperature H 2 /CO 2 separation in applications such as steam reforming and pre-combustion carbon capture where significant amounts of water are often present. However, PBIs are hydrophilic, and the impact of humidity on PBI gas separation properties is relatively unexplored. Furthermore, opportunity exists to elucidate the interplay between plasticization, free volume, and gas transport in glassy polymer membranes such as PBIs. Here, this study investigates the effect of humidity on H 2 , O 2 , and CO 2 permeabilities at 35 °C in a commercial PBI and two sulfone-containing PBIs. Water uptake significantly reduces PBI gas permeabilities at low humidities due to competitive sorption and antiplasticization. At high humidities, plasticization increases the permeabilities of larger gases in more hydrophilic PBIs. Effective fractional free volumes evaluated from gas permeation data and previously reported water sorption and dilation data suggest water plasticizes PBIs by increasing accessible free volume via enhanced molecular dynamics rather than by creating new free volume cavities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Aqueous ion partitioning in Nafion: Applicability of Manning's counter-ion condensation theory

Nafion is a well-studied polymer of significant interest as a fuel cell membrane due to rapid transport of protons, which is often ascribed, at least in part, to its phase-separated morphology. The literature detailing ion sorption and transport in Nafion diverges considerably from that of water purification membranes, with contrasting analyses and models. To help bridge these gaps and facilitate comparisons of membranes with various structures, this study presents measurements of ion activity coefficients and sorption in Nafion 117 equilibrated with aqueous solutions of NaCl, MgCl 2 , and Na 2 SO 4 , which are relevant to water purification. The experimental data are compared to a theoretical framework based on Manning's counter-ion condensation theory and Donnan theory. Good agreement between the model and data is observed for NaCl and MgCl 2 , using no adjustable parameters. However, the model significantly underpredicts Na 2 SO 4 solubility, which is attributed to ion pairing effects. Furthermore, the results highlight the general applicability of counter-ion condensation theory to highly charged polymers, including those exhibiting nanoscale ordering, while revealing fundamental limitations related to ion pairing.

36 MATERIALS SCIENCE↗

Co-ion specific effect on sodium halides sorption and transport in a cross-linked poly(p-styrene sulfonate-co-divinylbenzene) for membrane applications

Here, sodium halide sorption and transport in a cation exchange membrane based on cross-linked poly(p-styrene sulfonate-co-divinylbenzene) (CR61) were investigated experimentally and theoretically. At fixed co-ion valence, sodium halide partitioning between aqueous electrolyte solutions and ion exchange polymers is only minimally sensitive to co-ion chemical identity. NaCl, NaF and NaI exhibit similar solubility coefficients in CR61, which agrees reasonably well with predictions of the Donnan-Manning model, especially at high external salt concentrations. Ion activity coefficients in the membrane were evaluated and ion sorption thermodynamics were investigated. Ion diffusion coefficients in CR61 were predicted using a recently developed framework based on the Manning diffusion model, which accounts for electrostatic effects on ion diffusion, and the Mackie-Meares model, which accounts for tortuosity/area effects on ion diffusion in swollen polymers. Model predictions agree reasonably well with the experimental data, especially at high external salt concentrations. The observed decrease in salt diffusion coefficients in CR61 relative to values in aqueous solutions is due primarily to tortuosity/area effects. Salt diffusion coefficients correlate with co-ion hydrated radius and membrane water content. Finally, salt permeability coefficients predicted using the solution-diffusion model exhibit good agreement with experimental data, especially at external salt concentration greater than 0.1 mol/L.

42 ENGINEERING↗