Publications and source records attributed to Paul, Sebouh J..

A few-degree calorimeter for the future electron-ion collider

In this study, measuring the region 0.1 < Q 2 < 1.0 GeV 2 is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not feasible with current detector designs, resulting in the so-called Q 2 gap. In this work, we present a design for the Few-Degree Calorimeter (FDC), which addresses this issue. The FDC uses SiPM-on-tile technology with tungsten absorber and covers the range of -4.6 < η < -3.6. It offers fine transverse and longitudinal granularity, along with excellent time resolution, enabling standalone electron tagging. Our design represents the first concrete solution to bridge the Q 2 gap at the EIC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Leveraging staggered tessellation for enhanced spatial resolution in high-granularity calorimeters

Here we advance the concept of high-granularity calorimeters with staggered tessellations, underscoring the effectiveness of a design incorporating multifold staggering cycles based on hexagonal cells to enhance position resolution. Moreover, we introduce HEXPLIT, a sub-cell re-weighting algorithm tailored to harness staggered designs, resulting in additional performance improvements. By combining our proposed staggered design with HEXPLIT, we achieve an approximately twofold enhancement in position resolution for neutrons across a wide energy range, as compared to unstaggered designs. These findings hold the potential to elevate particle-flow performance across various forthcoming facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider

We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two approaches for the optical isolation of cells: "megatiles" with grooved boundaries between cells, and a 3D-printed plastic frame hosting individual cells. Further, we found that the latter suppresses optical crosstalk to negligible levels while providing an easier assembly method. Overall, these performance studies can help inform calorimeter design and realistic simulations of 5D showers (time, energy, position) for the EIC and other experiments.

47 OTHER INSTRUMENTATION↗

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

Herein we present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron–proton and electron–nucleus collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗