Search NASA⌕ Search

Engineering topics

Pazuchanics, Peter

Publications and source records attributed to Pazuchanics, Peter.

Photonic Doppler Velocimetry Probe Designed with Stereo Imaging

The velocity distribution of an imploding curved surface is measured with a miniature fiber-optic probe. The probe uses fiber matrix arrays that are focused onto different regions of this curved surface. A pyramid reflector deflects the interrogation onto specific regions of this curved surface. The fiber arrays record velocity along several hundred lines of sight with sub-nanosecond resolution. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called Photonic Doppler velocimetry, providing continuous time records. Within the probe, seven groups of miniature optical relay lenses are grouped into a close-packed array, allowing the interrogation of seven regions of interest. A six-faceted pyramid reflector with a conical hole drilled into its center is used to direct the light beams onto different regions. To minimize back reflections, the fiber matrix arrays are index matched onto the first relay lens made of fused silica. The optical lens design minimizes the laser beam diameters and also provides excellent imaging capabilities. Therefore, two of the fiber matrix arrays are replaced by coherent bundles for stereo imaging recorded by a high-speed framing camera. This requires additional cutouts of the pyramid reflector to allow imaging overlap. Six additional 1.5 mm diameter incoherent bundles are attached to the edges of the pyramid reflector and are used for illumination. Precision metrology on the direction cosines of the trajectories is measured to satisfy environmental requirements for vibration and temperature.

photonic doppler velocimetry, PDV, pyramid reflect↗

Ejecta Particle-Size Measurements in Vacuum and Helium Gas using Ultraviolet In-Line Fraunhofer Holography

An Ultraviolet (UV) in-line Fraunhofer holography diagnostic has been developed for making high-resolution spatial measurements of ejecta particles traveling at many mm/μsec. This report will discuss the development of the diagnostic including the high-powered laser system and high-resolution optical relay system. In addition, the system required to reconstruct the images from the hologram and the corresponding analysis of those images to extract particles will also be described. Finally, results from six high-explosive (HE), shock-driven Sn ejecta experiments will be presented. Particle size distributions will be shown that cover most of the ejecta velocities for experiments conducted in a vacuum, and helium gas environments. In addition, a modification has been made to the laser system that produces two laser pulses separated by 6.8 ns. This double-pulsed capability allows a superposition of two holograms to be acquired at two different times, thus allowing ejecta velocities to be measured directly. Results from this double pulsed experiment will be described.

36 MATERIALS SCIENCE↗

Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, Assembly, and Testing of a High-Resolution Relay Lens Used for Holography with Operation at Both Doubled and Tripled Nd:YAG Laser Wavelengths

The design and assembly of a nine-element lens that achieves >2000 lp/mm resolution at a 355-nm wavelength (ultraviolet) has been completed. By adding a doublet to this lens system, operation at a 532-nm wavelength (green) with >1100 lp/mm resolution is achieved. This lens is used with high-power laser light to record holograms of fast-moving ejecta particles from a shocked metal surface located inside a test package. Part of the lens and the entire test package are under vacuum with a 1-cm air gap separation. Holograms have been recorded with both doubled and tripled Nd:YAG laser light. The UV operation is very sensitive to the package window’s tilt. If this window is tilted by more than 0.1 degrees, the green operation performs with better resolution than that of the UV operation. The setup and alignment are performed with green light, but the dynamic recording can be done with either UV light or green light. A resolution plate can be temporarily placed inside the test package so that a television microscope located beyond the hologram position can archive images of resolution patterns that prove that the calibration wires, interference filter, holographic plate, and relay lenses are in their correct positions. Part of this lens is under vacuum, at the point where the laser illumination passes through a focus. Alignment and tolerancing of this high-resolution lens are presented. Resolution variation across the 12-mm field of view and throughout the 5-mm depth of field is discussed for both wavelengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗