Search NASA⌕ Search

Engineering topics

Pearson, Richard

Publications and source records attributed to Pearson, Richard.

Interlaboratory Study: Testing Reproducibility of Solid Biofuels Component Identification Using Reflected Light Microscopy

Considering global market trends and concerns about climate change and sustainability, increased biomass use for energy is expected to continue. As more diverse materials are being utilized to manufacture solid biomass fuels, it is critical to implement quality assessment methods to analyze these fuels thoroughly. One such method is reflected light microscopy (RLM), which has the potential to complement and enhance current standard testing, leading to improving fuel quality assessment and, ultimately, preventing avoidable air pollution. An interlaboratory study (ILS) was conducted to test the reproducibility of biomass fuels component identification using a reflected light microscopy technique. The exercise was conducted on thirty photomicrographs showing biomass and various undesired components (like plastics or mineral matter), which were purposely added (by the ILS organizers) to contaminate wood pellets and charcoal-based grilling fuels. Forty-six participants had various levels of difficulty identifying the marked components, and as a result, the percentage of correct answers ranged from 52.2 to 94.4%. Among the most difficult components to distinguish were petroleum products and inorganic matter. Various reasons led to the misidentification, including insufficient morphological descriptions of the components provided to participants, ambiguities of the nomenclature, limitations of the analytical and exercise method, and insufficient experience of the participants. Overall, the results indicate that RLM has the potential to enhance the quality assessment of biomass fuels. However, they also demonstrate that the petrographic classification used in this exercise requires further refinement before it can be standardized. While a new simplified classification of solid biomass fuels components was created as an outcome of this study, future research is necessary to refine the nomenclature, develop a microscopic morphological description of the components, and verify the accuracy of component identification with a follow-up ILS.

biomass↗

Nova V2362 Cygni (Nova Cygni 2006): Spitzer, Swift, and Ground-Based Spectral Evolution

Nova V2362 Cygni has undergone a number of very unusual changes. Ground-based spectroscopy initially revealed a normal sequence of events: the object faded and its near-infrared emission lines gradually shifted to higher excitation conditions until about day 100 when the optical fading reversed and the object slowly brightened. This was accompanied by a rise in the Swift X-ray telescope flux and a sudden shift in excitation of the visible and IR spectrum back to low levels. The new lower excitation spectrum revealed broad line widths and many P-Cygni profiles, all indicative of the ejection of a second shell. Eventually, dust formed, the X-ray brightness -- apparently unaffected by dust formation -- peaked and then declined, and the object faded at all wavelengths. The Spitzer dust spectra revealed a number of solid-state emission features that, at this time, are not identified.

Lynch, David K.↗

Multiple pass gas absorption cell utilizing a spherical mirror opposite one or more pair of obliquely disposed flat mirrors

A method and apparatus for passing light bundles through a multiple pass sampling cell is disclosed. The multiple pass sampling cell includes a sampling chamber having first and second ends positioned along a longitudinal axis of the sampling cell. The sampling cell further includes an entrance opening, located adjacent the first end of the sampling cell at a first azimuthal angular position. The entrance opening permits a light bundle to pass into the sampling cell. The sampling cell also includes an exit opening at a second azimuthal angular position. The light exit permits a light bundle to pass out of the sampling cell after the light bundle has followed a predetermined path.

Pearson, Richard↗

Monitoring Trace Contaminants in Air Via Ion Trap Mass Spectrometry

Recent passage of the Clean Air Act with its stricter regulation of toxic gas emissions, and the ever-growing number of applications which require faster turnaround times between sampling and analysis are two major factors which are helping to drive the development of new instrument technologies for in-situ, on-line, real-time monitoring. The ion trap, with its small size, excellent sensitivity, and tandem mass spectrometry capability is a rapidly evolving technology which is well-suited for these applications. In this paper, we describe the use of a commercial ion trap instrument for monitoring trace levels of chlorofluorocarbons (CFCs) and volatile organic compounds (VOCs) in air. A number of sample introduction devices including a direct transfer line interface, short column GC, and a cryotrapping interface are employed to achieve increasing levels of sensitivity. MS, MS/MS, and MS/MS/MS methods are compared to illustrate trade-offs between sensitivity and selectivity. Filtered Noise Field (FNF) technology is found to be an excellent means for achieving lower detection limits through selective storage of the ion(s) of interest during ionization. Figures of merit including typical sample sizes, detection limits, and response times are provided. The results indicate the potential of these techniques for atmospheric assessments, the High Speed Research Program, and advanced life support monitoring applications for NASA.

Palmer, Peter T.↗

Direct Monitoring of Trace Atmospheric Species via Ion Trap Mass Spectrometry

There is an ever-increasing emphasis on the part of government agencies, academia, and industry on enhancing our understanding of atmospheric processes and assessing the impact of human activities on these processes. While issues such as the ozone hole and rising levels of greenhouse gases have received major attention. relatively little is known about the types, concentrations, sources, and sinks of hydrocarbons in the troposphere and stratosphere. Such information would be of tremendous utility in assessing the roles of various anthropogenic and biogenic processes on global carbon cycles. An ion trap mass spectrometer has been developed for monitoring trace levels of hydrocarbons in the atmosphere on NASA's DC-8 "flying laboratory". This aircraft is used to provide measurements in support of a number of "Mission to Planet Earth" activities and tropospheric chemistry experiments. In past missions, specific compounds have been monitored via highly specialized instrumentation, fast GO, or collection of whole air samples for subsequent ground-based analysis. The ion trap has several features. including small size. excellent sensitivity, and broad applicability, which make it highly atttrat:ive for atmospheric monitoring. The design of this instrument, its air sampling interface. and the various complications associated with aircraft-deployment will be described. Data showing the sensitivity of the instrument for detecting hydrocarbons at mixing ratios below one part-per-billion, and the use of MS/MS for direct, on-line, real-time monitoring will be presented.

Palmer, P. T.↗