Search NASA⌕ Search

Engineering topics

Pearton, S. J.

Publications and source records attributed to Pearton, S. J..

At least 19 records

Color center in β -Ga 2 O 3 emitting at the telecom range

Transition metal (TM) ions incorporated into a host from a wide bandgap semiconductor are recognized as a promising system for quantum technologies with enormous potential. In this work, we report on a TM color center in β-Ga 2 O 3 with physical properties attractive for quantum information applications. The center is found to emit at 1.316 μm and exhibits weak coupling to phonons, with optically addressable higher-lying excited states, beneficial for single-photon emission within the telecom range (O-band). Using magneto-photoluminescence (PL) complemented by time-resolved PL measurements, we identify the monitored emission to be internal 1 E→ 3 A 2 spin-forbidden transitions of a 3d 8 TM ion with a spin-triplet ground state—a possible candidate for a spin qubit. We tentatively attribute this color center to a complex involving a sixfold coordinated Cu 3+ ion.

36 MATERIALS SCIENCE↗

Zika virus detection using antibody-immobilized disposable cover glass and AlGaN/GaN high electron mobility transistors

Zika virus detection was demonstrated using antibody-functionalized cover glasses externally connected to the gate electrode of an AlGaN/GaN high electron mobility transistor (HEMT). A pulsed bias voltage of 0.5 V was applied to an electrode on the region of the cover glass region functionalized with antibody, and the resulting changes of drain current of the HEMT were employed to determine the presence of Zika virus antigen concentration ranging from 0.1 to 100 ng/ml. The dynamic and static drain current changes as a function of Zika virus concentration were modeled with a spring-like elastic relaxation model and the Langmuir extension model, respectively. Excellent fits to the data were found with relaxation time constants of antibody and antigen molecules in the range of 11 μs and 0.66–24.4 μs, respectively, for the concentration range investigated. The ratio of antibody bound with antigen to the total available antibody on the functionalized contact window was in the range of 0.013–0.84 for the Zika antigen concentration range of 0.1–100 ng/ml. Since the HEMT is not exposed to the bio-solution, it can be used repeatedly. Here, the functionalized glass is the only disposable part in the detection system, showing the potential of this approach for hand-held, low cost sensor packages for point-of-care applications.

59 BASIC BIOLOGICAL SCIENCES↗

Ohmic contacts on n-type β-Ga 2 O 3 using AZO/Ti/Au

AZO interlayers between n-Ga 2 O 3 and Ti/Au metallization significantly enhance Ohmic contact formation after annealing at ≥ 300°C. Without the presence of the AZO, similar anneals produce only rectifying current-voltage characteristics. Transmission Line Measurements of the Au/Ti/AZO/Ga 2 O 3 stacks showed the specific contact resistance and transfer resistance decreased sharply from as-deposited values with annealing. The minimum contact resistance and specific contact resistance of 0.42 Ω-mm and 2.82 × 10 -5 Ω-cm 2 were achieved after a relatively low temperature 400°C annealing. In conclusion, the conduction band offset between AZO and Ga 2 O 3 is 0.79 eV and provides a favorable pathway for improved electron transport across this interface.

36 MATERIALS SCIENCE↗

Electrical, luminescent, and deep trap properties of Si doped n-GaN grown by pendeo epitaxy

Electrical and luminescent properties and deep trap spectra of Si doped GaN films grown by maskless epitaxial lateral overgrowth (MELO) are reported. The dislocation density in the wing region of the structure was 10{sup 6 }cm{sup −2}, while in the seed region it was 10{sup 8 }cm{sup −2}. The major electron traps present had activation energy of 0.56 eV and concentrations in the high 10{sup 15 }cm{sup −3} range. A comparison of diffusion length values and 0.56 eV trap concentration in MELO GaN and epitaxial lateral overgrowth (ELOG) GaN showed a good correlation, suggesting these traps could be effective in carrier recombination. The doped MELO films were more uniform in their electrical properties than either ELOG films or undoped MELO films. We also discuss the differences in deep trap spectra and luminescence spectra of low-dislocation-density MELO, ELOG, and bulk n-GaN samples grown by hydride vapor phase epitaxy. It is suggested that the observed differences could be caused by the differences in oxygen and carbon contamination levels.

36 MATERIALS SCIENCE↗

Effect of proton irradiation energy on AlGaN/GaN metal-oxide semiconductor high electron mobility transistors

The effects of proton irradiation energy on dc characteristics of AlGaN/GaN metal-oxide semiconductor high electron mobility transistors (MOSHEMTs) using Al 2 O 3 as the gate dielectric were studied. Al 2 O 3 /AlGaN/GaN MOSHEMTs were irradiated with a fixed proton dose of 5 × 10 15 cm -2 at different energies of 5, 10, or 15 MeV. More degradation of the device dc characteristics was observed for lower irradiation energy due to the larger amount of nonionizing energy loss in the active region of the MOSHEMTs under these conditions. The reductions in saturation current were 95.3%, 68.3%, and 59.8% and reductions in maximum transconductance were 88%, 54.4%, and 40.7% after 5, 10, and 15 MeV proton irradiation, respectively. Both forward and reverse gate leakage current were reduced more than one order of magnitude after irradiation. The carrier removal rates for the irradiation energies employed in this study were in the range of 127–289 cm -1 . These are similar to the values reported for conventional metal-gate high-electron mobility transistors under the same conditions and show that the gate dielectric does not affect the response to proton irradiation for these energies.

36 MATERIALS SCIENCE↗

Improvement of Drain Breakdown Voltage with A Back-Side Gate on AlGaN/GaN High Electron Mobility Transistors

The effect of a back gate on the dc performance of AlGaN/GaN high electron mobility transistor was investigated. The back gate was fabricated directly under the device active area by etching off the Si substrate, AlN nucleation layer, and graded AlGaN transition layer and depositing Ni/Au-based gate metal on the exposed GaN buffer layer. The reverse bias gate leakage current decreased from 3.9 × 10 -5 to 1.2 × 10 -5 mA/mm by applying -10 V at the back gate. Because of the suppression of gate leakage current by the back gate, the drain on/off ratio improved from 1.8 × 10 5 to 1.2 × 10 6 and the subthreshold swing from 204 to 137 mV/dec. The drain breakdown voltage could be improved by 40% when the back gate was biased at -25 V.

42 ENGINEERING↗

Movement of basal plane dislocations in GaN during electron beam irradiation

The movement of basal plane segments of dislocations in low-dislocation-density GaN films grown by epitaxial lateral overgrowth as a result of irradiation with the probing beam of a scanning electron microscope was detected by means of electron beam induced current. Only a small fraction of the basal plane dislocations was susceptible to such changes and the movement was limited to relatively short distances. The effect is explained by the radiation enhanced dislocation glide for dislocations pinned by two different types of pinning sites: a low-activation-energy site and a high-activation-energy site. Only dislocation segments pinned by the former sites can be moved by irradiation and only until they meet the latter pinning sites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrogen sensing characteristics of semipolar (112{sup ¯}2) GaN Schottky diodes

The hydrogen detection characteristics of semipolar (112{sup ¯}2) plane GaN Schottky diodes were investigated and compared to c-plane Ga- and N-polar and nonpolar a-plane (112{sup ¯}0) GaN diodes. The semipolar GaN diodes showed large current response to 4% hydrogen in nitrogen gas with an accompanying Schottky barrier reduction of 0.53 eV at 25 °C, and the devices exhibited full recovery to the initial current level upon switching to a nitrogen ambient. The current-voltage characteristics of the semipolar devices remained rectifying after hydrogen exposure, in sharp contrast to the case of c-plane N-polar GaN. These results show that the surface atom configuration and polarity play a strong role in hydrogen sensing with GaN.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dependence on proton energy of degradation of AlGaN/GaN high electron mobility transistors

The effects of proton irradiation energy on dc, small signal, and large signal rf characteristics of AlGaN/GaN high electron mobility transistors (HEMTs) were investigated. AlGaN/GaN HEMTs were irradiated with protons at fixed fluence of 51015/cm2 and energies of 5, 10, and 15 MeV. Both dc and rf characteristics revealed more degradation at lower irradiation energy, with reductions of maximum transconductance of 11%, 22%, and 38%, and decreases in drain saturation current of 10%, 24%, and 46% for HEMTs exposed to 15, 10, and 5MeV protons, respectively. The increase in device degradation with decreasing proton energy is due to the increase in linear energy transfer and corresponding increase in nonionizing energy loss with decreasing proton energy in the active region of the HEMTs. After irradiation, both subthreshold drain leakage current and reverse gate current decreased more than 1 order of magnitude for all samples. The carrier removal rate was in the range 121 336 cm1 over the range of proton energies employed in this study

Liu, L.↗

Impact of proton irradiation on dc performance of AlGaN/GaN high electron mobility transistors

The effects of proton irradiation dose on dc characteristics and the reliability of AlGaN/GaN high electron mobility transistors (HEMTs) were investigated. The HEMTs were irradiated with protons at a fixed energy of 5 MeV and doses ranging from 109 to 2 1014 cm-2. For the dc characteristics, there was only minimal degradation of saturation drain current (IDSS), transconductance (gm), electron mobility and sheet carrier concentration at doses below 2 1013 cm-2, while the reduction of these parameters were 15%, 9%, 41% and 16.6%, respectively, at a dose of 2 1014 cm-2. At this same dose condition, increases of 37% in drain breakdown voltage (VBR) and of 45% in critical voltage (Vcri) were observed. The improvement of device reliability was attributed to the modification of the depletion region due to the introduction of a higher density of defects after irradiation at a higher dose.

Liu, L.↗