Search NASA⌕ Search

Engineering topics

Peggs, Steve

Publications and source records attributed to Peggs, Steve.

Large radial shift experiments in RHIC and their implications for EIC design

The Hadron Storage Ring (HSR) in the future Electron-Ion Collider (EIC) must operate over a broad range of design circumferences. In 2018 preliminary beam studies on the circumference adjustment capabilities of the Relativistic Heavy Ion Collider (RHIC) were performed by applying a small momentum offset to the circulating bunches without adjusting any bending magnets. The off-momentum linear optics were corrected back to on-momentum conditions. Applying a similarly small deviation to the dipole fields of a select set of bending magnets provides a large radial shift over much of the RHIC (or HSR) circumference while leaving the design trajectory unchanged in the insertion regions. Here, this paper presents the design of the different lattice configurations foreseen as the most viable options for the required HSR circumference changes, and highlights the modifications necessary for regular operations and to allow for testing these new settings in RHIC. Experimental results from 2021 and 2022 are reviewed and compared to model predictions obtained from both MAD-X and Bmad. The implications of these results for HSR design are discussed.

43 PARTICLE ACCELERATORS↗

The EIC accelerator: design highlights and project status

The design of the electron-ion collider (EIC) at Brookhaven National Laboratory is well underway, aiming at a peak electron-proton luminosity of 10e+34 cm^-1·sec^-1. This high luminosity, the wide center-of-mass energy range from 29 to 141 GeV (e-p) and the high level of polarization require innovative solutions to maximize the performance of the machine, which makes the EIC one of the most challenging accelerator projects to date. The complexity of the EIC will be discussed, and the project status and plans will be presented.

43 PARTICLE ACCELERATORS↗

Progress on the design of the interaction region of the Electron-Ion Collider EIC

We present an update on the design of the Interaction Region (IR) for the the Electron Ion Collider (EIC) being built at Brookhaven National Laboratory (BNL). The EIC will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV with luminosities of up to 10^34 /cm^2/s. The IR, located at RHIC's IR6, is designed to meet the requirements of the nuclear physics community as outlined in [1]. A second IR is technically feasible but not part of the project.The magnet apertures are sufficiently large to allow desired collision products to reach the far-forward detectors; the electron magnet apertures in the rear direction are chosen to be large enough to pass the synchrotron radiation fan. In the forward direction the electron apertures are large enough for non-Gaussian tails.The paper discusses a number of recent recent changes to the design. The machine free region was recently increased from 9 to 9.5 m to allow for more space in the forward direction for the detector. The superconducting magnets on the forward side now operate at 1.9 K, which helps crosstalk and space issues.

43 PARTICLE ACCELERATORS↗

Optimizing the Design Tunes of the Electron Storage Ring of the Electron-Ion Collider

The Electron-Ion Collider (EIC) presently under construction at Brookhaven National Laboratory will collide polarized high energy electron beams with hadron beams with luminosities up to 10^34cm^{-2}s^{-1} in the center mass energy range of 20-140 GeV. Preliminary beam-beam simulations resulted in an optimum working point of (.08, .06) in the Electron Storage Ring (ESR). However, during the ESR polarization simulation study this working point was found to be less than optimal for electron polarization. In this article, we present beam-beam simulation results in a wide range tune scan to search for optimal ESR design tunes that are acceptable for both beam-beam and polarization performances.

43 PARTICLE ACCELERATORS↗

Design Status of the Electron-Ion Collider

The Electron-Ion Collider is gearing up for "Critical Decision 2", theproject baseline with defined scope, cost and schedule.Lattice designs are beingfinalized, and preliminary component design is being carried out. Beam dynamicsstudies such as dynamic aperture optimization, instability and polarizationstudies, and beam-beam simulations are continuing in parallel. We report onthe latest developments and the overall status of the project, and presentthe plans for future activities.

43 PARTICLE ACCELERATORS↗

The United States Department of Energy and National Institutes of Health Collaboration: Medical Care Advances via Discovery in Physical Sciences

Over several months, representatives from the U.S. Department of Energy (DOE) Office of Science and National Institutes of Health (NIH) had a number of meetings that lead to the conclusion that innovations in the Nation's health care could be realized by more directed interactions between NIH and DOE. It became clear that the expertise amassed and instrumentation advances developed at the DOE physical science laboratories to enable cutting-edge research in particle physics could also feed innovation in medical healthcare. To meet their scientific mission, the DOE laboratories created advances in such technologies as particle beam generation, radioisotope production, high-energy particle detection and imaging, superconducting particle accelerators, superconducting magnets, cryogenics, high-speed electronics, artificial intelligence, and big data. To move forward, NIH and DOE initiated the process of convening a joint work- shop which occurred on July 12th and 13th, 2021. Here, this Special Report presents a summary of the findings of the collaborative workshop and introduces the goals of the next one.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector Solenoid Compensation for the Electron-Ion Collider

The central detector in the present EIC design includes a 4 m long solenoid with an integrated strength of up to 12 Tm. The electron beam passes on-axis through the solenoid, but the hadron beam has an angle of 25 mrad. Thus the solenoid couples horizontal and vertical betatron motion in both electron and hadron storage rings, and causes a vertical closed orbit excursion in the hadron ring. The solenoid also couples the transverse and longitudinal motions of both beams, when crab cavities are also considered. In this paper, we present schemes for closed orbit correction and coupling compensation at the IP, including crabbing.

43 PARTICLE ACCELERATORS↗

Conceptual design of the ESS-SCANDINAVIA

The conceptual design of the European Spallation Source-Scandinavia (ESS-S) is presented. The accelerator system baseline draws heavily on state-of-the-art mature technologies that are being employed in the CERN Linac4 and SPL projects, although advances with spoke resonator and sputtered superconducting cavities are also being evaluated for reliable performance. Irradiation damage due to proton beam losses is a key issue for linac and target components. Their optimized design is performed from an engineering perspective, using the last updated versions of mechanical design codes which were already qualified for irradiated components. Finally, future upgrades of power and intensity of the proton linac are considered, including the design optimization of the Target Station (proton/neutron convertor), with the possibility of increasing the average pulsed power deposition up to 7.5 MW. All possible upgrades will be taken into account for the final design review, in the frame of the costs and constraints given with the site decision.

Peggs, Steve↗

Conceptual Design of the ESS LINAC

A three year design update for the European Spallation Source (ESS) LINAC is just starting. A review of this work is presented. Acceleration in the medium energy part of the LINAC using spoke cavities has been optimised, and the rest of the machine has been redesigned to incorporate this optimisation. The ESS LINAC will deliver an average power of 5 MW to the target in the nominal design. The possibility to upgrade to a higher power LINAC of 7.5 MW has been included in all design features.

43 PARTICLE ACCELERATORS↗