Quantifying Black Carbon Deposition Over the Greenland Ice Sheet from Forest Fires in Canada

Black carbon (BC) concentrations observed in 22 snowpits sampled in the northwest sector of the Greenland ice sheet in April 2014 have allowed us to identify a strong and widespread BC aerosol deposition event, which was dated to have accumulated in the pits from two snow storms between 27 July and 2 August 2013. This event comprises a significant portion (57 on average across all pits) of total BC deposition over 10 months (July 2013 to April 2014). Here we link this deposition event to forest fires burning in Canada during summer 2013 using modeling and remote sensing tools. Aerosols were detected by both the Cloud-Aerosol Lidar with Orthogonal Polarization (on board CALIPSO) and Moderate Resolution Imaging Spectroradiometer (Aqua) instruments during transport between Canada and Greenland. We use high-resolution regional chemical transport modeling (WRF-Chem) combined with high-resolution fire emissions (FINNv1.5) to study aerosol emissions, transport, and deposition during this event. The model captures the timing of the BC deposition event and shows that fires in Canada were the main source of deposited BC. However, the model underpredicts BC deposition compared to measurements at all sites by a factor of 2100. Underprediction of modeled BC deposition originates from uncertainties in fire emissions and model treatment of wet removal of aerosols. Improvements in model descriptions of precipitation scavenging and emissions from wildfires are needed to correctly predict deposition, which is critical for determining the climate impacts of aerosols that originate from fires.

albedo↗

Overshooting of Clean Tropospheric Air in the Tropical Lower Stratosphere as Seen by the CALIPSO Lidar

The evolution of aerosols in the tropical upper troposphere/lower stratosphere between June 2006 and October 2009 is examined using the observations of the space borne CALIOP lidar aboard the CALIPSO satellite. Superimposed on several volcanic plumes and soot from an extreme biomass-burning event in 2009, the measurements reveal the existence of fast cleansing episodes of the lower stratosphere to altitudes as high as 20 km. The cleansing of the full 14-20km layer takes place within 1-4 months. Its coincidence with the maximum of convective activity in the southern tropics, suggests that the cleansing is the result of a large number of overshooting towers, injecting aerosol-poor tropospheric air into the lower stratosphere. The enhancements of aerosols at the tropopause level during the NH summer may be due to the same transport process but associated with intense sources of aerosols at the surface. Since, the tropospheric air flux derived from CALIOP observations during North Hemisphere winter is 5 20 times larger than the slow ascent by radiative heating usually assumed, the observations suggest that convective overshooting is a major contributor to troposphere-to-stratosphere transport with concommitant implications to the Tropical Tropopause Layer top height, chemistry and thermal structure.

Vernier, J. P.↗

Comparison of CALIPSO-Like, LaRC, and MODIS Retrievals of Ice Cloud Properties over SIRTA in France and Florida during CRYSTAL-FACE

This study compares cirrus particle effective radius retrieved by a CALIPSO-like method with two similar methods using MODIS, MODI Airborne Simulator (MAS), and GOES imagery. The CALIPSO-like method uses lidar measurements coupled with the split-window technique that uses the infrared spectral information contained at the 8.65-micrometer, 11.15-micrometer and 12.05-micrometer bands to infer the microphysical properties of cirrus clouds. The two other methods, sing passive remote sensing at visible and infrared wavelengths, are the operational MODIS cloud products (referred to by its archival product identifier MOD06 for MODIS Terra) and MODIS retrievals performed by the CERES team at LaRC (Langley Research Center) in support of CERES algorithms; the two algorithms will be referred to as MOD06- and LaRC-method, respectively. The three techniques are compared at two different latitudes: (i) the mid-latitude ice clouds study uses 18 days of observations at the Palaiseau ground-based site in France (SIRTA: Site Instrumental de Recherche par Teledetection Atmospherique) including a ground-based 532 nm lidar and the Moderate Resolution Imaging Spectrometer (MODIS) overpasses on the Terra Platform, (ii) the tropical ice clouds study uses 14 different flight legs of observations collected in Florida, during the intensive field experiment CRYSTAL-FACE (Cirrus Regional Study of Tropical Anvils and cirrus Layers-Florida Area Cirrus Experiment), including the airborne Cloud Physics Lidar (CPL) and the MAS. The comparison of the three methods gives consistent results for the particle effective radius and the optical thickness, but discrepancies in cloud detection and altitudes. The study confirms the value of an active remote-sensing method (CALIPSO-like) for the study of sub-visible ice clouds, in both mid-latitudes and tropics. Nevertheless, this method is not reliable in optically very thick tropical ice clouds.

Chiriaco, M.↗

Validation of POLDER/ADEOS data using a ground-based lidar network: Preliminary results for semi-transparent and cirrus clouds

At mid and tropical latitudes, cirrus clouds are present more than 50% of the time in satellites observations. Due to their large spatial and temporal coverage, and associated low temperatures, cirrus clouds have a major influence on the Earth-Ocean-Atmosphere energy balance through their effects on the incoming solar radiation and outgoing infrared radiation. At present the impact of cirrus clouds on climate is well recognized but remains to be asserted more precisely, for their optical and radiative properties are not very well known. In order to understand the effects of cirrus clouds on climate, their optical and radiative characteristics of these clouds need to be determined accurately at different scales in different locations i.e. latitude. Lidars are well suited to observe cirrus clouds, they can detect very thin and semi-transparent layers, and retrieve the clouds geometrical properties i.e. altitude and multilayers, as well as radiative properties i.e. optical depth, backscattering phase functions of ice crystals. Moreover the linear depolarization ratio can give information on the ice crystal shape. In addition, the data collected with an airborne version of POLDER (POLarization and Directionality of Earth Reflectances) instrument have shown that bidirectional polarized measurements can provide information on cirrus cloud microphysical properties (crystal shapes, preferred orientation in space). The spaceborne version of POLDER-1 has been flown on ADEOS-1 platform during 8 months (October 96 - June 97), and the next POLDER-2 instrument will be launched in 2000 on ADEOS-2. The POLDER-1 cloud inversion algorithms are currently under validation. For cirrus clouds, a validation based on comparisons between cloud properties retrieved from POLDER-1 data and cloud properties inferred from a ground-based lidar network is currently under consideration. We present the first results of the validation.

Chepfer, H.↗

Boundary layer structure over the ocean observed by LEANDRE 1 during a tramontane event

A new airborne backscatter lidar, has been developed by CNRS (Service d'Aeronomie, (SA) Laboratoire de Meteorologie Dynamique (LMD) and the Institut des Sciences de 1'Univers) in the frame of the LEANDRE research program. It has been qualified on board the ARAT in autumn 1989 and spring 1990 and was involved in its first cooperative campaign during PYREX in October and November 1990. During this campaign, lidar observations of the perturbations induced on tropospheric flow and boundary layer structure were performed, and results are presented. A large number of experiments were performed, for synoptic situation description (meteorological radiosoundings, constant level balloons) and local flow analysis (aircrafts, radars, sodars). For the first time in such an experiment, a lidar has been flown on a research aircraft to perform altitude resolved observations of these perturbations, and we will present here results obtained for deflected flow structure. In the presence of a synoptic northerly flow, part of it is deflected to the east by the Pyrenees, and accelerated over the Mediterranean by the mountain surroundings. In this case, a low level wind is generated (the Tramontane) bringing cold and dry air over the Mediterranean Sea. As the sea is still at a warm temperature in November (around 17 degrees), an Internal Marine Boundary Layer rapidly grows over the first tens of kilometers and stabilizes at about 1 km depth, corresponding to an altitude just below the Lifting Condensation Level. The whole Marine Atmospheric Boundary Layer (MABL) is characterized by highly turbulent motions bringing large humid particles from the surface up to its top. The lidar signal due to scattering by these particles is then representative of the turbulent kinetic energy in this layer.

Flamant, C.↗

Airborne lidar and radiometric observations of PBL- and low clouds

Boundary layer- and low altitude clouds over open ocean and continent areas have been studied during several field campaigns since mid-1990 using the French airborne backscatter lidar LEANDRE in conjunction with on-board IR and visible radiometers. LEANDRE is an automatic system, and a modification of the instrumental parameters, when airborne, is computer controlled through an operator keyboard. The vertical range squared lidar signals and instrument status are displayed in real time on two dedicated monitors. The lidar is used either down- or up-looking while the aircraft is flying above or below clouds. A switching of the viewing configuration takes about a minute. The lidar measurements provide a high resolution description of cloud morphology and holes in cloud layers. The flights were conducted during various meteorological conditions on single or multilayer stratocumulus and cumulus decks. Analysis on a single shot basis of cloud top (or bottom) altitude and a plot of the corresponding histogram allows one to determine a probability density function (PDF). The preliminary results show the PDFs for cloud top are not Gaussian and symmetric about the mean value. The skewness varies with atmospheric conditions. An example of results recorded over the Atlantic ocean near Biarritz is displayed, showing: (1) the range squared lidar signals as a function of time (here 100 s corresponds to about 8 km, 60 shots are averaged on horizontal); the Planetary Boundary Layer (PBL) - up to 600 m - is observed at the beginning of the leg as well as on surface returns, giving an indication of the porosity; (2) the cloud top altitude variation between 2.4 to 2.8 km during the 150 to 320 s section; and (3) the corresponding PDF. Similar results are obtained on stratocumulus over land. Single shot measurements can be used also to determine an optical porosity at a small scale as well as a fractional cloudiness at a larger scale. A comparison of cloud top altitude retrieved from lidar and narrowbeam IR radiometer is conducted to study the scale integration problem. A good agreement within less than 100 m relies on spatial uniformity and an optically thick layer. In the presence of holes, a discrepancy is observed. This is illustrated in figure 2, displaying as a function of time (1) the lidar signals; (2) the target temperature (either clouds or sea surface) retreived from a narrowbeam IR radiometer, 17 C is the sea surface temperature on that day; and (3) the visible flux, linked to cloud albedo, measured by a pyranometer. In preparation of ASTEX, down- and up-looking measurements where conducted on stratocumulus clouds over the Atlantic Ocean near Quimper in Brittany. Depending on the flight pattern orientation with respect to the wind, the top and bottom cloud morphologies are different. Preliminary results are given on cloud morphology, cloud top PDFs, optical porosity, fractional cloudiness, and comparison of lidar and radiometric measurements.

Flamant, P. H.↗

ECLIPS at LMD: Preliminary results of phase 2

The LMD (Laboratoire de Meteorologie Dynamique) ground-based backscatter lidar station (48 degrees 4 N, 02 degrees 0 E) near Paris was operated daily during the phase 2 of the Experimental Closed Lidar Pilot Study (ECLIPS) from May 22 to June 19, 1991 simultaneously with a radiometric equipment recording the downward short wavelength (SW) and long wavelength (LW) fluxes. A day-by-day summary of the field measurement as a function of universal time (UT) is given. Considering a 5 days week, there are only two days of missing data (05/31 and 06/06) in our record. The nearby meteorological station (10 km away) provides rawindsounding at 00UT and 12UT. During two days, the French airborne lidar LEANDRE was flown over the ground-based station. The airborne equipment looked down while the ground based equipment looked up. The two lidars were operated at 532 nm, and the on-board radiometers were identical to the ones on the ground. The measurements were synchronized with Advanced Very High Resolution Radiometer (AVHIRR) overpasses as required. We also indicate the Meteosat data corresponding to the period of measurements. Two examples of simultaneous ground-based lidar, pygeometer and pyranometer data are displayed.

Valentin, R.↗

The 2nd phase of the LEANDRE program: Water-vapor DIAL measurement

As a follow-on of the backscattered lidar, a differential absorption lidar (LEANDRE 2) is now being developed as part of the LEANDRE program for airborne meteorological studies. The primary measurement objective of LEANDRE 2 is water vapor. Pressure and temperature measurements are aimed at a second stage. The goals are to obtain a horizontal resolution of a few hundred meters for a vertical resolution of less than a hundred meters, with an absolute accuracy of 10 percent for humidity measurement. As compatibility is an important feature between the 2 first phases of LEANDRE, most of the LEANDRE 1 sub-system will be used and adapted for LEANDRE 2. For example, detection electronics, central computer, detectors and telescope will be the same. However, important modifications have to be done on the laser source, and spectral control has to be added. Most of the work is thus devoted to those developments, and the status is presented here.

Quaglia, P.↗

DIAL simulations for satellite water vapor profile measurements within the BEST project

The project BEST has been proposed by several laboratories of the French Space Agency (CNES) as part of the GEWEX program. Its objective is the study of the energy budget of the tropical system, and aims at measuring different components of the water cycle by coupling several observing systems. As part of this, Service d'Aeronomie (SA) proposed to study a Differential Absorption Lidar (DIAL) system to measure tropical water vapor profiles and to determine humidity convergence fields, when coupled with the Doppler wind lidar. We have performed simulation analyses for water vapor measurement from the selected orbit of 400 km. For these simulations, we have adopted an atmospheric model developed at SA. We have optimized, by a Monte Carlo statistical method, the system parameters and evaluated bias and standard deviation of the retrieved water vapor mixing ratio.

Chazette, P.↗

Stratospheric ozone measurements from the 1985 MAP/GLOBUS NO(x) campaign

Nine experiments obtained stratospheric ozone measurements during the fall 1985 Middle Atmosphere Program (MAP) Global Budget of Stratospheric Trace Constituents (GLOBUS) NO(x) campaign. Measurements are grouped into four sets from four air masses and compared. Agreement between individual experiments and weighted mean profiles is generally within 10 percent and within absolute accuracies. Dobson Umkehr values in layer 5 differ by more than absolute accuracies from weighted mean profiles. Brewer sonde values for one data set are outside absolute accuracies near the ozone peak. Solar UV occultation measurements are 30-35 percent less than the weighted mean profile and outside absolute accuracies. Measurements from the Exospheric Satellite backscattered ultraviolet experiment, not previously compared with other techniques, agree within 10-15 percent of weighted mean profiles. Results of the campaign are generally consistent with those of four previous intercomparison campaigns.

Robbins, D.↗

General comparison of ozone vertical profiles obtained by various techniques during the 1983 MAP/GLOBUS campaign

As part of the 1983 MAP/GLOBUS campaign, atmospheric ozone profile measurements were made using a large variety of different techniques both from balloon platforms and the ground. It is shown that, for most techniques, the measured height distributions agree to within + or - 5 percent with the exception of the remote visible absorption method. This + or - 5 percent uncertainty is of the order of the individual intersystem accuracy. It is suggested that since the differences with the visible absorption method are in magnitude rather than in form, the absorption cross-section data could be the possible cause for the discrepancy.

Matthews, W. A.↗

Lidar stratospheric ozone measurements at the observatoire de Haute Provence (France)

Strastospheric ozone monitoring is of particular importance to confirm present day theories predicting a maximal ozone depletion, due to chlorofluorocarbon emission, in the 35 to 45 km altitude range. Measurements presently rely on both ground based and satellite-borne passive experiments. Such systems have been recently shown to have intrinsic limitations mainly due to atmospheric aerosol presence and calibration problems. During the last few years, active lidar profiling of the ozone vertical distribution by the Differential Absorption Laser technique (DIAL) in the UV wavelength range has been developed using two different laser sources: a Nd-YAG pumped dye laser which enables a large tuning range of the UV emitted wavelengths; and exciplex laser sources using xenon chloride as an active medium and emitting at 308 nm, the off wavelength being usually generated by Raman shifting techniques. Advantages and limitations of using both of these systems are briefly discussed.

Godin, S.↗

Alexandrite laser source for atmospheric lidar measurements

During the past years, there has been a marked increase in interest in the applications of vibronic solid state lasers to meteorology and atmospheric physics. Two airborne lidar programs are now under development in France. The differential absorption lidar (DIAL) method with vibronic solid state lasers is very attractive for water vapor, temperature and pressure measurements. Alexandrite laser and titanium-sapphire are both suitable for these applications. However, only alexandrite rods are commercially available. The requirements on the laser source for airborne dial applications are two fold: (1) a restriction on laser linewidth and a requirement on stability and tunability with a good spectral purity; and (2) a requirement on the time separation between the two pulses. These constraints are summarized.

Pelon, J.↗

Active Optical Sounding of Ozone and Minor Constituents in the Middle Atmosphere: a Review of Ground-based Lidar Measurements

Due to the rapid development of powerful laser sources in the UV wavelength range which includes nd:yag pumped dye lasers and excimer lasers, ground-based lidar systems are now operational for ozone monitoring in the troposphere and the stratosphere. Such systems will play an important role in the determination of long term ozone trends in the photochemical region. The capacities of active lidar systems in terms of high temporal and spatial resolution and measurements continuity, allow the observation of the ozone variations at various time and space scales which are important in present day areas of interest. The already operational character of the lidar systems will constitute the basis for development of a ground-base network for middle atmospheric observations of ozone and other race gases.

Megie, G.↗

Ozone and water vapor monitoring using a ground-based lidar system

Measurements of atmospheric ozone and water vapor profiles obtained using a differential absorption lidar (DIAL) technique at Haute Provence Observatory are reported. The DIAL technique is based on the comparison of differences in attenuation in backscattered signals at wavelengths centered on strong absorptions or absorption lines of the species in question, and wavelengths corresponding to weaker or no absorption. The system in use is based on three lasers - a Nd:YAG Q-switched laser frequency doubled to emit at 532 nm, and two tunable narrowline dye lasers used to convert this emission into the IR or UV spectral regions. Ozone concentration profiles have been recorded up to a height of 30 km, and reveal large day-to-day variations in number density which were correlated with a decrease in tropopause height. Measurements of water vapor concentrations show a variability of the mixing ratio at heights up to 2.5 km representative of dynamic processes, and a variability above 2.5 km that is within the measurement error. Day-to-day variations in tropospheric mixing ratio were also observed.

Megie, G.↗

Ground-based lidar measurements of ozone, water vapor and aerosols in the lower stratosphere and troposphere

Lidar measurements of ozone and water vapor concentrations were performed during several field experiments in 1980-1981 by means of the differential absorption laser technique. Profiles up to 26 km for ozone and up to 9 km for water vapor are presented. Also, a lidar survey of aerosol layers ranging from 12 to 23 km were performed following the Mt. St. Helens major eruption (May 1980). Experiments were conducted at the CNRS lidar facility of the Haute Provence Observatory which is located in southern France (44 deg N, 5 deg E). For ozone a vertical profile is recorded in three sequences, each requiring 15 min of acquisition time. The relative accuracy is better than 5 percent at the lower altitude and falls to 20 percent at 25 km. For water vapor the time sequences are 4 min or 8 min long and the accuracy is better than 10 percent in the lower troposphere.

Flamant, P. H.↗