Search NASA⌕ Search

Engineering topics

Pena, C.

Publications and source records attributed to Pena, C..

Performance of a second generation of the Fermilab Constant Fraction Discriminator ASIC for time-stamping long-strip AC-LGAD sensors.

We present the design and performance characterization results of the second generation of the novel Fermilab Constant Fraction Discriminator ASIC (FCFD) developed to readout AC-coupled low gain avalanche detector (AC-LGAD) sensors. This study presents the performance of the ASIC which was optimized specifically for reading out strip AC-LGAD sensors designed for ePIC experiment at EiC. Performance was measured using charge injection and particle beams with prototype AC-LGAD sensors wirebonded to the FCFD ASIC.

Apresyan, A.↗

FLAG Review 2021

Abstract We review lattice results related to pion, kaon, D -meson, B -meson, and nucleon physics with the aim of making them easily accessible to the nuclear and particle physics communities. More specifically, we report on the determination of the light-quark masses, the form factor $$f_+(0)$$ f + ( 0 ) arising in the semileptonic $$K \rightarrow \pi $$ K → π transition at zero momentum transfer, as well as the decay constant ratio $$f_K/f_\pi $$ f K / f π and its consequences for the CKM matrix elements $$V_{us}$$ V us and $$V_{ud}$$ V ud . Furthermore, we describe the results obtained on the lattice for some of the low-energy constants of $$SU(2)_L\times SU(2)_R$$ S U ( 2 ) L × S U ( 2 ) R and $$SU(3)_L\times SU(3)_R$$ S U ( 3 ) L × S U ( 3 ) R Chiral Perturbation Theory. We review the determination of the $$B_K$$ B K parameter of neutral kaon mixing as well as the additional four B parameters that arise in theories of physics beyond the Standard Model. For the heavy-quark sector, we provide results for $$m_c$$ m c and $$m_b$$ m b as well as those for the decay constants, form factors, and mixing parameters of charmed and bottom mesons and baryons. These are the heavy-quark quantities most relevant for the determination of CKM matrix elements and the global CKM unitarity-triangle fit. We review the status of lattice determinations of the strong coupling constant $$\alpha _s$$ α s . We consider nucleon matrix elements, and review the determinations of the axial, scalar and tensor bilinears, both isovector and flavor diagonal. Finally, in this review we have added a new section reviewing determinations of scale-setting quantities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fermilab Test Beam Facility Annual Report: FY19

This Technical Memorandum (TM) summarizes the Fermilab Test Beam Faciltiy (FTBF) operations for FY2019. It is one of a series of annual publications intended to gather information in one place. This TM discusses the experiments performed at the Test Beam from November 2018 to July 2019. The experiments are listed in Table 1. Each experiment wrote a summary that was edited for clarity and is included in this report.

43 PARTICLE ACCELERATORS↗

CACTUS: A depleted monolithic active timing sensor using a CMOS radiation hard technology

The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The required time resolution is of the order of tens of picoseconds, with a spatial granularity of the order of 1 mm. A time measurement at this precision level will also be of interest beyond the LHC and beyond high energy particle physics. We present in this paper the first developments towards a radiation hard Depleted Monolithic Active Pixel Sensor (DMAPS), with high-resolution time measurement capability. The technology chosen is a standard high voltage CMOS process, in conjunction with a high resistivity detector material, which has already proven to efficiently detect particles in tracking applications after several hundred of Mrad of irradiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FLAG Review 2019: Flavour Lattice Averaging Group (FLAG)

Abstract We review lattice results related to pion, kaon, D -meson, B -meson, and nucleon physics with the aim of making them easily accessible to the nuclear and particle physics communities. More specifically, we report on the determination of the light-quark masses, the form factor $$f_+(0)$$ f + ( 0 ) arising in the semileptonic $$K \rightarrow \pi $$ K → π transition at zero momentum transfer, as well as the decay constant ratio $$f_K/f_\pi $$ f K / f π and its consequences for the CKM matrix elements $$V_{us}$$ V us and $$V_{ud}$$ V ud . Furthermore, we describe the results obtained on the lattice for some of the low-energy constants of $$SU(2)_L\times SU(2)_R$$ S U ( 2 ) L × S U ( 2 ) R and $$SU(3)_L\times SU(3)_R$$ S U ( 3 ) L × S U ( 3 ) R Chiral Perturbation Theory. We review the determination of the $$B_K$$ B K parameter of neutral kaon mixing as well as the additional four B parameters that arise in theories of physics beyond the Standard Model. For the heavy-quark sector, we provide results for $$m_c$$ m c and $$m_b$$ m b as well as those for D - and B -meson decay constants, form factors, and mixing parameters. These are the heavy-quark quantities most relevant for the determination of CKM matrix elements and the global CKM unitarity-triangle fit. We review the status of lattice determinations of the strong coupling constant $$\alpha _s$$ α s . Finally, in this review we have added a new section reviewing results for nucleon matrix elements of the axial, scalar and tensor bilinears, both isovector and flavor diagonal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First beam tests of prototype silicon modules for the CMS High Granularity Endcap Calorimeter

The High Luminosity phase of the Large Hadron Collider will deliver 10 times more integrated luminosity than the existing collider, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry. As part of its upgrade program, the Compact Muon Solenoid collaboration is designing a high-granularity calorimeter (HGCAL) to replace the existing endcap calorimeters. It will feature unprecedented transverse and longitudinal readout and triggering segmentation for both electromagnetic and hadronic sections. The electromagnetic section and a large fraction of the hadronic section will be based on hexagonal silicon sensors of 0.5–1 cm 2 cell size, with the remainder of the hadronic section being based on highly-segmented scintillators with silicon photomultiplier readout. The intrinsic high-precision timing capabilities of the silicon sensors will add an extra dimension to event reconstruction, especially in terms of pileup rejection. First hexagonal silicon modules, using the existing Skiroc2 front-end ASIC developed for CALICE, have been tested in beams at Fermilab and CERN in 2016. Here, we present results from these tests, in terms of system stability, calibration with minimum-ionizing particles and resolution (energy, position and timing) for electrons, and the comparisons of these quantities with GEANT4-based simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Timing with shower maximum detectors based on pixelated micro-channel plates

Future calorimeters and shower maximum detectors at high luminosity colliders need to be highly radiation resistant and very fast. One exciting option for such a detector is a calorimeter composed of a secondary emitter as the active element. Here, we outline the study and development of a secondary emission calorimeter prototype using micro-channel plates (MCP) as the active element, which directly amplify the electromagnetic shower signal. We also demonstrate the feasibility of using a bare MCP within an inexpensive and robust housing without the need for any photo cathode, which is a key requirement for high radiation tolerance. Test beam measurements of the prototype were performed with 120 GeV primary protons and secondary beams at the Fermilab Test Beam Facility, demonstrating basic calorimetric measurements and precision timing capabilities. Using multiple pixel readout on the MCP, we demonstrate a transverse spatial resolution of 0.8 mm, and time resolution better than 40 ps for electromagnetic showers.

47 OTHER INSTRUMENTATION↗

Precision Timing with Silicon Sensors for Use in Calorimetry

The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 × 10 34 cm -2 s -1 . The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL- LHC and future collider experiments which face very high radiation environments. We present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. We show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LYSO based precision timing calorimeters

In this report we outline the study of the development of calorimeter detectors using bright scintillating crystals. We discuss how timing information with a precision of a few tens of pico seconds and below can significantly improve the reconstruction of the physics events under challenging high pileup conditions to be faced at the High-Luminosity LHC or a future hadron collider. The particular challenge in measuring the time of arrival of a high energy photon lies in the stochastic component of the distance of initial conversion and the size of the electromagnetic shower. We present studies and measurements from test beams for calorimeter based timing measurements to explore the ultimate timing precision achievable for high energy photons of 10 GeV and above. We focus on techniques to measure the timing with a high precision in association with the energy of the photon. We present test-beam studies and results on the timing performance and characterization of the time resolution of LYSO-based calorimeters. We demonstrate time resolution of 30 ps is achievable for a particular design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of lattice results concerning low-energy particle physics: Flavour Lattice Averaging Group (FLAG)

We review lattice results related to pion, kaon, D- and B-meson physics with the aim of making them easily accessible to the particle-physics community. More specifically, we report on the determination of the light-quark masses, the form factor f + (0), arising in the semileptonic K → π transition at zero momentum transfer, as well as the decay constant ratio f K /f π and its consequences for the CKM matrix elements V us and V ud . Furthermore, we describe the results obtained on the lattice for some of the low-energy constants of SU(2) L × SU(2) R and SU(3) L × SU(3) R Chiral Perturbation Theory. We review the determination of the B K parameter of neutral kaon mixing as well as the additional four B parameters that arise in theories of physics beyond the Standard Model. The latter quantities are an addition compared to the previous review. For the heavy-quark sector, we provide results for m c and m b (also new compared to the previous review), as well as those for D- and B-meson-decay constants, form factors, and mixing parameters. These are the heavy-quark quantities most relevant for the determination of CKM matrix elements and the global CKM unitarity-triangle fit. Finally, we review the status of lattice determinations of the strong coupling constant α s .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct tests of a pixelated microchannel plate as the active element of a shower maximum detector

One possibility to make a fast and radiation resistant shower maximum detector is to use a secondary emitter as an active element. We report our studies of microchannel plate photomultipliers (MCPs) as the active element of a shower-maximum detector. We present test beam results obtained using Photonis XP85011 to detect secondary particles of an electromagnetic shower. We focus on the use of the multiple pixels on the Photonis MCP in order to find a transverse two-dimensional shower distribution. A spatial resolution of 0.8 mm was obtained with an 8 GeV electron beam. As a result, a method for measuring the arrival time resolution for electromagnetic showers is presented, and we show that time resolution better than 40 ps can be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test beam studies of silicon timing for use in calorimetry

The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 X 10 34 cm –2 s –1 . The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL-LHC and future collider experiments which face very high radiation environments. In this article, we present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. Lastly, we show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of lattice results concerning low-energy particle physics

We review lattice results related to pion, kaon, D- and B-meson physics with the aim of making them easily accessible to the particle physics community. More specifically, we report on the determination of the light-quark masses, the form factor f+(0), arising in semileptonic K -> pi transition at zero momentum transfer, as well as the decay constant ratio fK/fpi of decay constants and its consequences for the CKM matrix elements Vus and Vud. Furthermore, we describe the results obtained on the lattice for some of the low-energy constants of SU(2)LxSU(2)R and SU(3)LxSU(3)R Chiral Perturbation Theory and review the determination of the BK parameter of neutral kaon mixing. The inclusion of heavy-quark quantities significantly expands the FLAG scope with respect to the previous review. Therefore, for this review, we focus on D- and B-meson decay constants, form factors, and mixing parameters, since these are most relevant for the determination of CKM matrix elements and the global CKM unitarity-triangle fit. In addition we review the status of lattice determinations of the strong coupling constant alpha_s.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗