Search NASA⌕ Search

Engineering topics

Pena, Gary

Publications and source records attributed to Pena, Gary.

Electrofracturing of Shale at Elevated Pressure

Electrofracturing deeply buried shale formations could be used to increase reservoir permeability and improve reservoir production without requiring large volumes of freshwater. This paper describes a novel experimental system and initial test results to electrofracture shale under high confining pressures. Core-scale laboratory testing was performed on twelve rock samples recovered from a shale gas reservoir. Each sample was subjected to confining pressures of 20.7 MPa (3000 psi) or 58.6 MPa (8000 psi), representative of overburden pressures at depth. Samples were then subjected to application of high voltage until specimen fracture. The experiments produced deformed samples with multiple fracture types, both parallel and oblique to bedding planes. Electrofracturing increased permeabilities by up to nine orders of magnitude for extended time periods. Rock fracture and throughgoing fractures were demonstrated. Computed tomography images revealed the creation of fractures and tube/tunnel flow channels, which resisted closure under hydrostatic pressures up to 58.6 MPa. The breakdown energy and permeability changes in the sample were independent of applied confining pressure. The cumulative energy input required for fracture depended on applied confining pressure and sample length. The energy required to fracture samples up to 9 cm in length is generally more than 0.5 kJ/cm, but no greater than 1 kJ/cm. Our results show that electrofracture of shales under confining pressure is possible and could be a possible water-free mechanism for reservoir stimulation.

04 OIL SHALES AND TAR SANDS↗

Ferroelectric opening switch

A ferroelectric opening switch is enabled by controlled polarization switching via nucleation in a ferroelectric material, such as BaTiO3, Pb(Zr,Ti)O3, LiNbO3, LiTaO3, or variants thereof. For example, nucleation sites can be provided by mechanical seeding, grain boundaries, or optical illumination. The invention can be used as an opening switch in large scale pulsed-power systems. However, the switch can also be used in compact pulsed-power systems (e.g., as drivers for high power microwave systems), as passive fault limiters for high voltage dc (HVDC) systems, and/or in other high power applications.

30 DIRECT ENERGY CONVERSION↗

Submerged Medium Voltage Cable Systems at Nuclear Power Plants: A Review of Research Efforts Relevant to Aging Mechanisms and Condition Monitoring

In a submerged environment, power cables may experience accelerated insulation degradation due to water-related aging mechanisms. Direct contact with water or moisture intrusion in the cable insulation system has been identified in the literature as a significant aging stressor that can affect performance and lifetime of electric cables. Progressive reduction of the dielectric strength is commonly a result of water treeing which involves the development of permanent hydrophilic structures in the insulation coinciding with the absorption of water into the cable. Water treeing is a phenomenon in which dendritic microvoids are formed in electric cable insulation due to electrochemical reactions, electromechanical forces, and diffusion of contaminants over time. These reactions are caused by the combined effects of water presence and high electrical stresses in the material. Water tree growth follows a tree-like branching pattern, increasing in volume and length over time. Although these cables can be “dried out,” water tree degradation, specifically the growth of hydrophilic regions, is believed to be permanent and typically worsens over time. Based on established research, water treeing or water induced damage can occur in a variety of electric cables including XLPE, TR-XLPE and other insulating materials, such as EPR and butyl rubber. Once water trees or water induced damage form, the dielectric strength of an insulation material will decrease gradually with time as the water trees grow in length, which could eventually result in failure of the insulating material. Under wet conditions or in submerged environments, several environmental and operational parameters can influence water tree initiation and affect water tree growth. These parameters include voltage cycling, field frequency, temperature, ion concentration and chemistry, type of insulation material, and the characteristics of its defects. In this effort, a review of academic and industrial literature was performed to identify: 1) findings regarding the degradation mechanisms of submerged cabling and 2) condition monitoring methods that may prove useful in predicting the remaining lifetime of submerged medium voltage power cables. The research was conducted by a multi-disciplinary team, and sources included official NRC reports, national laboratory reports, IEEE standards, conference and journal proceedings, magazine articles, PhD dissertations, and discussions with experts. The purpose of this work was to establish the current state-of-the-art in material degradation modeling and cable condition monitoring techniques and to identify research gaps. Subsequently, future areas of focus are recommended to address these research gaps and thus strengthen the efficacy of the NRC’s developing cable condition monitoring program. Results of this literature review and details of the testing recommendations are presented in this report.

24 POWER TRANSMISSION AND DISTRIBUTION↗