Search NASA⌕ Search

Engineering topics

Peng, Qiyu

Publications and source records attributed to Peng, Qiyu.

An 8.8 ps RMS Resolution Time-To-Digital Converter Implemented in a 60 nm FPGA with Real-Time Temperature Correction

This paper presented a non-uniform multiphase (NUMP) time-to-digital converter (TDC) implemented in a field-programmable gate array (FPGA) with real-time automatic temperature compensation. NUMP-TDC is a novel, low-cost, high-performance TDC that has achieved an excellent performance in Altera Cyclone V FPGA. The root mean square (RMS) for the intrinsic timing resolution was 2.3 ps. However, the propagation delays in the delay chain of some FPGAs (for example, the Altera Cyclone 10 LP) vary significantly as the temperature changes. Thus, the timing performances of NUMP-TDCs implemented in those FPGAs are significantly impacted by temperature fluctuations. In this study, a simple method was developed to monitor variations in propagation delays using two registers deployed at both ends of the delay chain and compensate for changes in propagation delay using a look-up table (LUT). When the variations exceeded a certain threshold, the LUT for the delay correction was updated, and a bin-by-bin correction was launched. Using this correction approach, a resolution of 8.8 ps RMS over a wide temperature range (5 °C to 80 °C) had been achieved in a NUMP-TDC implemented in a Cyclone 10 LP FPGA.

59 BASIC BIOLOGICAL SCIENCES↗

OpenPET Hardware, Firmware, Software, and Board Design Files

OpenPET is an open source, flexible, high-performance, and modular data acquisition system for a variety of applications. The OpenPET electronics are capable of reading analog voltage or current signals from a wide variety of sensors. The electronics boards make extensive use of field programmable gate arrays (FPGAs) to provide flexibility and scalability. Firmware and software for the FPGAs and computer are used to control and acquire data from the system. The command and control flow is similar to the data flow, however, the commands are initiated from the computer similar to a tree topology (i.e., from top-to-bottom). Each node in the tree discovers its parent and children, and all addresses are configured accordingly. A user (or a script) initiates a command from the computer. This command will be translated and encoded to the corresponding child (e.g., SB, MB, DB, etc.). Consecutively, each node will pass the command to its corresponding child(ren) by looking at the destination address. Finally, once the command reaches its desired destination(s) the corresponding node(s) execute(s) the command and send(s) a reply, if required. All the firmware, software, and the electronics board design files are distributed through the OpenPET website (http://openpet.lbl.gov).

Abu-Nimeh, Faisal↗

Architecture and Implementation of OpenPET Firmware and Embedded Software

OpenPET is an open source, modular, extendible, and high-performance platform suitable for multi-channel data acquisition and analysis. Due to the versatility of the hardware, firmware, and software architectures, the platform is capable of interfacing with a wide variety of detector modules not only in medical imaging but also in homeland security applications. Analog signals from radiation detectors share similar characteristics-a pulse whose area is proportional to the deposited energy and whose leading edge is used to extract a timing signal. As a result, a generic design method of the platform is adopted for the hardware, firmware, and software architectures and implementations. The analog front-end is hosted on a module called a Detector Board, where each board can filter, combine, timestamp, and process multiple channels independently. The processed data is formatted and sent through a backplane bus to a module called Support Board, where 1 Support Board can host up to eight Detector Board modules. The data in the Support Board, coming from 8 Detector Board modules, can be aggregated or correlated (if needed) depending on the algorithm implemented or runtime mode selected. It is then sent out to a computer workstation for further processing. The number of channels (detector modules), to be processed, mandates the overall OpenPET System Configuration, which is designed to handle up to 1,024 channels using 16-channel Detector Boards in the Standard System Configuration and 16,384 channels using 32-channel Detector Boards in the Large System Configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast method for optical simulation of flood maps of light-sharing detector modules

Optical simulation of the detector module level is highly desired for Position Emission Tomography (PET) system design. Commonly used simulation toolkits such as GATE are not efficient in the optical simulation of detector modules with complicated light-sharing configurations, where a vast amount of photons need to be tracked. Here, we present a fast approach based on a simplified specular reflectance model and a structured light-tracking algorithm to speed up the photon tracking in detector modules constructed with polished finish and specular reflector materials. We also simulated conventional block detector designs with different slotted light guide patterns using the new approach and compared the outcomes with those from GATE simulations. And while the two approaches generated comparable flood maps, the new approach was more than 200–600 times faster. The new approach has also been validated by constructing a prototype detector and comparing the simulated flood map with the experimental flood map. The experimental flood map has nearly uniformly distributed spots similar to those in the simulated flood map. In conclusion, the new approach provides a fast and reliable simulation tool for assisting in the development of light-sharing-based detector modules with a polished surface finish and using specular reflector materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Modality Phantom Development

Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agargelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗