Search NASA⌕ Search

Engineering topics

Penko, Paul F.

Publications and source records attributed to Penko, Paul F..

At least 19 records

Emissions Measured in the Exhaust of a CFM-56 Engine on a DC-8

A very extensive set of gaseous- and particulate-emissions data from an in service commercial aircraft engine was obtained by a team of researchers from NASA, the Environmental Protection Agency, and the Department of Defense. The program was led and organized by Dr. Chowen Wey of the UEET Project Office at the NASA Glenn Research Center and was dubbed the Aircraft Particle Emissions eXperiment (APEX). Testing was done at the NASA Dryden Flight Research Center. The main object of APEX was to identify particulate emissions from commercial-aircraft engines.

Wey, Changlie↗

Small Engine Technology (SET) - Task 4, Regional Turboprop/Turbofan Engine Advanced Combustor Study

Under the SET Program Task 4 - Regional Turboprop/Turbofan Engine Advanced Combustor Study, a total of ten low-emissions combustion system concepts were evaluated analytically for three different gas turbine engine geometries and three different levels of oxides of nitrogen (NOx) reduction technology, using an existing AlliedSignal three-dimensional (3-D) Computational Fluid Dynamics (CFD) code to predict Landing and Takeoff (LTO) engine cycle emission values. A list of potential Barrier Technologies to the successful implementation of these low-NOx combustor designs was created and assessed. A trade study was performed that ranked each of the ten study configurations on the basis of a number of manufacturing and durability factors, in addition to emissions levels. The results of the trade study identified three basic NOx-emissions reduction concepts that could be incorporated in proposed follow-on combustor technology development programs aimed at demonstrating low-NOx combustor hardware. These concepts are: high-flow swirlers and primary orifices, fuel-preparation cans, and double-dome swirlers.

Reynolds, Robert↗

Simulation of Low-density Nozzle Plumes in Non-zero Ambient Pressures

The direct simulation Monte-Carlo (DSMC) method was applied to the analysis of low-density nitrogen plumes exhausting from a small converging-diverging nozzle into finite ambient pressures. Two cases were considered that simulated actual test conditions in a vacuum facility. The numerical simulations readily captured the complicated flow structure of the overexpanded plumes adjusting to the finite ambient pressures, including Mach disks and barrel shaped shocks. The numerical simulations compared well to experimental data of Rothe.

Chung, Chan-Hong↗

Molecular gas dynamics applied to low-thrust propulsion

The Direct Simulation Monte Carlo method is currently being applied to study flowfields of small thrusters, including both the internal nozzle and the external plume flow. The DSMC method is employed because of its inherent ability to capture nonequilibrium effects and proper boundary physics in low-density flow that are not readily obtained by continuum methods. Accurate prediction of both the internal and external nozzle flow is important in determining plume expansion which, in turn, bears directly on impingement and contamination effects.

Zelesnik, Donna↗

Assessment of three numerical methods for the computation of a low-density plume flow

Results from three numerical methods including one based on the Navier-Stokes equations, one based on kinetic theory using the DSMC method, and one based on the Boltzmann equation with a Krook-type collision term are compared to each other and to experimental data for a model problem of heated nitrogen flow in a conical nozzle expanding into a vacuum. The problem simulates flow in a resistojet, a low-thrust, electrothermal rocket. The continuum method is applied to both the internal flow and near-field plume. The DSMC and Boltzmann methods are applied primarily to the plume. Experimental measurements of Pitot pressure and flow angle, taken with an apparatus that duplicates the model nozzle flow, are used in the comparisons.

Penko, Paul F.↗

Experimental and numerical investigations of low-density nozzle and plume flows of nitrogen

New experimental data are used to show that the direct simulation Monte Carlo (DSMC) method provides an accurate description of a low-density flow in the nozzle and the near-field expansion of a small rocket for two slightly different experimental configurations. These results verify the DSMC method in an expansion flow for the first time. From a number of different gas/surface interaction models, it is found that fully diffuse reflection gives the best agreement with experiment.

Boyd, Iain D.↗

FDDO and DSMC analyses of rarefied gas flow through 2D nozzles

Two different approaches, the finite-difference method coupled with the discrete-ordinate method (FDDO), and the direct-simulation Monte Carlo (DSMC) method, are used in the analysis of the flow of a rarefied gas expanding through a two-dimensional nozzle and into a surrounding low-density environment. In the FDDO analysis, by employing the discrete-ordinate method, the Boltzmann equation simplified by a model collision integral is transformed to a set of partial differential equations which are continuous in physical space but are point functions in molecular velocity space. The set of partial differential equations are solved by means of a finite-difference approximation. In the DSMC analysis, the variable hard sphere model is used as a molecular model and the no time counter method is employed as a collision sampling technique. The results of both the FDDO and the DSMC methods show good agreement. The FDDO method requires less computational effort than the DSMC method by factors of 10 to 40 in CPU time, depending on the degree of rarefaction.

Chung, Chan-Hong↗

DSMC analysis of species separation in rarefied nozzle flows

The direct-simulation Monte Carlo method has been used to investigate the behavior of a small amount of a harmful species in the plume and the backflow region of nuclear thermal propulsion rockets. Species separation due to pressure diffusion and nonequilibrium effects due to rapid expansion into a surrounding low-density environment are the most important factors in this type of flow. It is shown that a relatively large amount of the lighter species is scattered into the backflow region and the heavier species becomes negligible in this region due to the extreme separation between species. It is also shown that the type of molecular interaction between the species can have a substantial effect on separation of the species.

Chung, Chan-Hong↗

Numerical modeling of fluid and electromagnetic phenomena in an arcjet

An explicit numerical technique is used to solve the axisymmetric reduced electromagnetic field equation. The effect of an electrical arc on a viscous, axisymmetric flow is approximated using an implicit thin layer Navier-Stokes solver with additional electromagnetic source terms in conjunction with the explicit finite difference code.

Flowe, Anita C.↗

Measurement and analysis of a small nozzle plume in vacuum

Measurements of Pitot pressure and flow angle were made in the plume of a nozzle flowing nitrogen and exhausting to a vacuum. The measurements were compared to results from a numerical simulation of the flow that was based on kinetic theory and used the direct-simulation Monte Carlo (DSMC) method. Numerical results were compared with measurements made in the plume at various axial and radial stations. Total pressure measurements were made with Pitot tubes sized for specific regions of the plume. Flow angle measurements were made with a conical probe. The measurement area for flow angle extended to 160 mm (5 exit diameters) downstream of the nozzle exit plane and radially to 60 mm (1.9 exit diameters) from the plume axis. The total pressure measurements extended 480 mm (16 exit diameters) downstream and radially to 60 mm. Comparisons of computed results from the DSMC method with measurements of flow angle displayed improved agreement with increasing distance from the exit plane. Pitot pressures computed from the DSMC method were in reasonably good agreement with experimental results over the entire measurement area.

Penko, Paul F.↗

Internal structure of shock waves in disparate mass mixtures

The detailed flow structure of a normal shock wave for a gas mixture is investigated using the direct-simulation Monte Carlo method. A variable diameter hard-sphere (VDHS) model is employed to investigate the effect of different viscosity temperature exponents (VTE) for each species in a gas mixture. Special attention is paid to the irregular behavior in the density profiles which was previously observed in a helium-xenon experiment. It is shown that the VTE can have substantial effects in the prediction of the structure of shock waves. The variable hard-sphere model of Bird shows good agreement, but with some limitations, with the experimental data if a common VTE is chosen properly for each case. The VDHS model shows better agreement with the experimental data without adjusting the VTE. The irregular behavior of the light-gas component in shock waves of disparate mass mixtures is observed not only in the density profile, but also in the parallel temperature profile. The strength of the shock wave, the type of molecular interactions, and the mole fraction of heavy species have substantial effects on the existence and structure of the irregularities.

Chung, Chan-Hong↗

Numerical and experimental investigations of rarefied nozzle and plume flows of nitrogen

Numerical and experimental investigations are performed for the rarefied flow of nitrogen through a small nozzle which is expanded into near-vacuum conditions. Two different numerical studies are undertaken: the first employs a continuum approach in solving the Navier-Stokes equations, and the second employs a particle approach through use of the direct simulation Monte Carlo method (DSMC). The experimental investigation concerns the measurement of pressure, using a Pitot tube, in the nozzle exit plane and near-field of the plume. Comparison of the experimental and numerical data at the nozzle exit reveals that the DSMC technique provides the more accurate description of the expanding flow. It is discovered that the DSMC solutions are quite sensitive to the model employed to simulate the interaction between the gas and the nozzle wall surface. It is concluded that the simplistic fully diffuse model is quite satisfactory for the present application.

Boyd, Iain D.↗

Pressure measurements in a low-density nozzle plume for code verification

Measurements of Pitot pressure were made in the exit plane and plume of a low-density, nitrogen nozzle flow. Two numerical computer codes were used to analyze the flow, including one based on continuum theory using the explicit MacCormack method, and the other on kinetic theory using the method of direct-simulation Monte Carlo (DSMC). The continuum analysis was carried to the nozzle exit plane and the results were compared to the measurements. The DSMC analysis was extended into the plume of the nozzle flow and the results were compared with measurements at the exit plane and axial stations 12, 24 and 36 mm into the near-field plume. Two experimental apparatus were used that differed in design and gave slightly different profiles of pressure measurements. The DSMC method compared well with the measurements from each apparatus at all axial stations and provided a more accurate prediction of the flow than the continuum method, verifying the validity of DSMC for such calculations.

Penko, Paul F.↗

Experimental and analytical comparison of flowfields in a 110 N (25 Lbf) H2/O2 rocket

A gaseous hydrogen/gaseous oxygen 110 N (25 lbf) rocket has been examined through the RPLUS code using the full Navier-Stokes equations with finite-rate chemistry. Performance tests were conducted on the rocket in an altitude test facility. Preliminary parametric analyses have been performed for a range of mixture ratios and fuel film cooling percentages. It is shown that the computed values of specific impulse and characteristic exhaust velocity follow the trend of the experimental data. Specific impulse computed by the code is lower than the comparable test values by about two to three percent. The computed characteristic exhaust velocity values are lower than the comparable test values by three to four percent. Thrust coefficients computed by the code are found to be within two percent of the measured values. It is concluded that the discrepancy between computed and experimental performance values could not be attributed to experimental uncertainty.

Reed, Brian D.↗

Pressure measurements in a low-density nozzle plume for code verification

Measurements of Pitot pressure were made in the exit plane and plume of a low-density, nitrogen nozzle flow. Two numerical computer codes were used to analyze the flow, including one based on continuum theory using the explicit MacCormack method, and the other on kinetic theory using the method of direct-simulation Monte Carlo (DSMC). The continuum analysis was carried to the nozzle exit plane and the results were compared to the measurements. The DSMC analysis was extended into the plume of the nozzle flow and the results were compared with measurements at the exit plane and axial stations 12, 24 and 36 mm into the near-field plume. Two experimental apparatus were used that differed in design and gave slightly different profiles of pressure measurements. The DSMC method compared well with the measurements from each apparatus at all axial stations and provided a more accurate prediction of the flow than the continuum method, verifying the validity of DSMC for such calculations.

Penko, Paul F.↗

Experimental and analytical comparison of flowfields in a 110 N (25 lbf) H2/O2 rocket

A gaseous hydrogen/gaseous oxygen 110 N (25 lbf) rocket was examined through the RPLUS code using the full Navier-Stokes equations with finite rate chemistry. Performance tests were conducted on the rocket in an altitude test facility. Preliminary parametric analyses were performed for a range of mixture ratios and fuel film cooling pcts. It is shown that the computed values of specific impulse and characteristic exhaust velocity follow the trend of the experimental data. Specific impulse computed by the code is lower than the comparable test values by about two to three percent. The computed characteristic exhaust velocity values are lower than the comparable test values by three to four pct. Thrust coefficients computed by the code are found to be within two pct. of the measured values. It is concluded that the discrepancy between computed and experimental performance values could not be attributed to experimental uncertainty.

Reed, Brian D.↗

Efficient Monte Carlo simulation of rarefied flow in a small nozzle

The flow of carbon dioxide through a small conical nozzle is computed using two different numerical approaches. The first of these is the direct simulation Monte Carlo method in which the physical phenomena are modeled at the molecular level. The second technique solves the Navier-Stokes equations of fluid flow. The purpose of the paper is to compare the solutions generated by these two methods for the conditions prevailing in a small, low density nozzle. The comparison between the two sets of solutions reveals only small differences. However, the flow properties in the thick viscous layer close to the nozzle at the exit plane show important deviations which have implications for the subsequent determination of the plume backflow.

Boyd, Iain D.↗