Search NASA⌕ Search

Engineering topics

Pennycook, Timothy J.

Publications and source records attributed to Pennycook, Timothy J..

Column-by-column observation of dislocation motion in CdTe: Dynamic scanning transmission electron microscopy

The dynamics of partial dislocations in CdTe have been observed at the atomic scale using aberration-corrected scanning transmission electron microscopy (STEM), allowing the mobility of different dislocations to be directly compared: Cd-core Shockley partial dislocations are more mobile than Te-core partials, and dislocation cores with unpaired columns have higher mobility than those without unpaired columns. The dynamic imaging also provides insight into the process by which the dislocations glide. Dislocations with dangling bonds on unpaired columns are found to be more mobile because the dangling bonds mediate the bond exchanges required for the dislocations to move. Furthermore, a screw dislocation has been resolved to dissociate into a Shockley partial-dislocation pair along two different directions, revealing a way for the screw dislocation to glide in the material. The results show that dynamic STEM imaging has the potential to uncover the details of dislocation motion not easily accessible by other means. This research was sponsored by the U.S. DOE, Office of Energy Efficiency and Renewable Energy, Foundational Program to Advance Cell Efficiency (F-PACE, DE-FOA-0000492), (CL, YLW, NP, YFY, SJP), the Office of DOE-BES, Materials Science and Engineering Division (ARL), DOE Grant No. DE-FG02-09ER46554 (YYZ, STP), and a user project supported by ORNL's Center for Nanophase Materials Sciences (CNMS), which is also sponsored by DOE-BES. Supercomputer time was provided by the National Center for Supercomputing Applications which is supported by the DOE Office of Science under Contract No. DE-AC02-05CH11231, and the Extreme Science and Engineering Discovery Environment (XSEDE), which is supported by National Science Foundation Grant No. ACI-1053575. Chen Li [No. 656378] and Timothy Pennycook [No.655760] are currently funded by the European Union's Marie Sklodowska-Curie Grants.

36 MATERIALS SCIENCE↗

High On/Off Ratio Memristive Switching of Manganite/Cuprate Bilayer by Interfacial Magnetoelectricity

Memristive switching serves as the basis for a new generation of electronic devices. Conventional memristors are two-terminal devices in which the current is turned on and off by redistributing point defects, e.g., vacancies. Memristors based on alternative mechanisms have been explored, but achieving both high on/off ratio and low switching energy, as needed in applications, remains a challenge. This paper reports memristive switching in La 0.7 Ca 0.3 MnO 3 /PrBa 2 Cu 3 O 7 bilayers with an on/off ratio greater than 103 and results of density functional theory calculations in terms of which it is concluded that the phenomenon is likely the result of a new type of interfacial magnetoelectricity. More specifically, this study shows that an external electric field induces subtle displacements of the interfacial Mn ions, which switches on/off an interfacial magnetic “dead layer”, resulting in memristive behavior for spin-polarized electron transport across the bilayer. The interfacial nature of the switching entails low energy cost, about of a tenth of atto Joule for writing/erasing a “bit”. To conclude, the results indicate new opportunities for manganite/cuprate systems and other transition metal oxide junctions in memristive applications.

36 MATERIALS SCIENCE↗

Oxygen disorder, a way to accommodate large epitaxial strains in oxides

Density-functional calculations (total-energy comparisons) and checks for negative-frequency phonon modes are employed as a stability indicator to show that, in rutile- and fluorite-structure oxides, e.g., zirconia strained by a strontium titanate substrate, oxygen-sublattice disorder can be the energetically preferred way to accommodate strain.

36 MATERIALS SCIENCE↗

Smart align -- A new tool for robust non-rigid registration of scanning microscope data

Many microscopic investigations of materials may benefit from the recording of multiple successive images. This can include techniques common to several types of microscopy such as frame averaging to improve signal-to-noise ratios (SNR) or time series to study dynamic processes or more specific applications. In the scanning transmission electron microscope, this might include focal series for optical sectioning or aberration measurement, beam damage studies or camera-length series to study the effects of strain; whilst in the scanning tunnelling microscope, this might include bias voltage series to probe local electronic structure. Whatever the application, such investigations must begin with the careful alignment of these data stacks, an operation that is not always trivial. In addition, the presence of low-frequency scanning distortions can introduce intra-image shifts to the data. Here, we describe an improved automated method of performing non-rigid registration customised for the challenges unique to scanned microscope data specifically addressing the issues of low-SNR data, images containing a large proportion of crystalline material and/or local features of interest such as dislocations or edges. Careful attention has been paid to artefact testing of the non-rigid registration method used, and the importance of this registration for the quantitative interpretation of feature intensities and positions is evaluated.

36 MATERIALS SCIENCE↗

Insights into the physical chemistry of materials from advances in HAADF-STEM

The observation that, ‘‘New tools lead to new science’’[P. S. Weiss, ACS Nano., 2012, 6(3), 1877–1879], is perhaps nowhere more evident than in scanning transmission electron microscopy (STEM). Advances in STEM have endowed this technique with several powerful and complimentary capabilities. For example, the application of high-angle annular dark-field imaging has made possible real-space imaging at subangstrom resolution with Z-contrast (Z = atomic number). Further advances have wrought: simultaneous real-space imaging and elemental identification by using electron energy loss spectroscopy (EELS); 3-dimensional (3D) mapping by depth sectioning; monitoring of surface diffusion by time-sequencing of images; reduced electron energy imaging for probing graphenes; etc. In this paper we review how these advances, often coupled with first-principles theory, have led to interesting and important new insights into the physical chemistry of materials. We then review in detail a few specific applications that highlight some of these STEM capabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Efficient phase contrast imaging in STEM using a pixelated detector. Part 1: Experimental demonstration at atomic resolution

In this paper, we demonstrate a method to achieve high efficiency phase contrast imaging in aberration corrected scanning transmission electron microscopy (STEM) with a pixelated detector. The pixelated detector is used to record the Ronchigram as a function of probe position which is then analyzed with ptychography. Ptychography has previously been used to provide super-resolution beyond the diffraction limit of the optics, alongside numerically correcting for spherical aberration. Here we rely on a hardware aberration corrector to eliminate aberrations, but use the pixelated detector data set to utilize the largest possible volume of Fourier space to create high efficiency phase contrast images. The use of ptychography to diagnose the effects of chromatic aberration is also demonstrated. In conclusion, the four dimensional dataset is used to compare different bright field detector configurations from the same scan for a sample of bilayer graphene. Our method of high efficiency ptychography produces the clearest images, while annular bright field produces almost no contrast for an in-focus aberration-corrected probe.

36 MATERIALS SCIENCE↗