Search NASA⌕ Search

Engineering topics

Pepijn Veefkind

Publications and source records attributed to Pepijn Veefkind.

Sun-as-a-Star Spectral Line Variability in the 300–2390 nm Wavelength Range

Combining the near-daily Ozone Monitoring Instrument (OMI) and Tropospheric Monitoring Instrument (TROPOMI) measurements of solar spectra, we construct line indices (line-core to line-flanks ratios) for various transitions (mainly Fe I) in the 300–2390 nm spectral domain. The indices are supplemented by the wavelength-binned fluxes from OMI and Total and Spectral Solar Irradiance Sensor (TSIS-1). To study the short-term (solar-rotational) patterns, we normalize the indices and fluxes to the minimum-activity epoch, then de-trend them with 81 day running means. Comparisons of the de-trended TSIS-1 and OMI fluxes with the NASA-NOAA-LASP SSI (NNLSSI1) model show excellent agreement, to (0.5–2.2) × 10 -4 in the normalized and de-trended data. The data are subjected to a multiregression analysis against quantities representing the facular brightening and the sunspot darkening. The de-trended line indices and average fluxes show different sensitivities to these two solar magnetic-activity manifestations, with the fluxes being far more susceptible to the sunspot component. The de-trended line indices experience a rapid drop of activity levels towards longer wavelengths, albeit with a large rebound in the short-wave infrared (SWIR) domain that is caused by the ubiquitous, temperature-sensitive CO transitions. The wavelength-dependent activity also falls, however much slower, in the de-trended average fluxes. Qualitatively similar behavior is captured by semiempirical models.

Solar spectral Irradiance↗

Tropospheric and Stratospheric Ozone Profiles during the 2019 TROpomi vaLIdation eXperiment (TROLIX-19)

A TROPOspheric Monitoring Instrument (TROPOMI) validation campaign was held in the Netherlands based at the CESAR (Cabauw Experimental Site for Atmospheric Research) observatory during September 2019. The TROpomi vaLIdation eXperiment (TROLIX-19) consisted of active and passive remote sensing platforms in conjunction with several balloon-borne and surface chemical (e.g., ozone and nitrogen dioxide) measurements. The goal of this joint NASA-KNMI geophysical validation campaign was to make intensive observations in the TROPOMI domain in order to be able to establish the quality of the L2 satellite data products under realistic conditions, such as non-idealized conditions with varying cloud cover and a range of atmospheric conditions at a rural site. The research presented here focuses on using ozone lidars from NASA's Goddard Space Flight Center to better evaluate the characterization of ozone throughout TROLIX-19. Results of comparisons to the lidar systems with balloon, space-borne and ground-based passive measurements are shown. In addition, results are compared to a global coupled chemistry meteorology model to illustrate the vertical variability and columnar amounts of both tropospheric and stratospheric ozone during the campaign period.

ozone↗

Ozone Monitoring Instrument (OMI) collection 4: establishing a 17-year-long series of detrended level-1b data

The Ozone Monitoring Instrument (OMI) was launched on 15 July 2004, with an expected mission lifetime of 5 years. After more than 17 years in orbit the instrument is still functioning satisfactorily and in principle can continue doing so until the expected decommissioning of its platform Aura in 2025. In order to continue the datasets acquired by OMI and the Microwave Limb Sounder, the mission was extended up to at least 2023. Actions have been taken to ensure the proper functioning of the OMI operations, the data processing, and the calibration monitoring system until the eventual end of the mission. For the data processing a new level-0 (L0) to level-1b (L1b) data processor was built based on the recent developments for the TROPOspheric Monitoring Instrument (TROPOMI). With corrections for the degradation of the instrument now included, it is feasible to generate a new data collection to supersede the current collection-3 data products and reprocess the data of the entire mission up to now. This paper describes the differences between the collection-3 and collection-4 data. It will be shown that the collection-4 L1b data comprise a clear improvement with respect to the previous collections. By correcting for the gentle optical and electronic aging that has occurred over the past 17 years, OMI’s ability to make trend-quality ozone measurements has further improved.

UV↗

Combined UV and IR Ozone Profile Retrieval from TROPOMI and CrIS Measurements

Vertical ozone profiles from combined spectral measurements in the ultraviolet and infrared spectral range were retrieved by using data from the TROPOspheric Monitoring Instrument on the Sentinel-5 Precursor (TROPOMI/S5P) and the Cross-track Infrared Sounder on the Suomi National Polar-orbiting Partnership (CrIS/Suomi-NPP), which are flying in loose formation 3 min apart in the same orbit. A previous study of ozone profiles retrieved exclusively from TROPOMI UV spectra showed that the vertical resolution in the troposphere is clearly limited (Mettig et al., 2021). The vertical resolution and the vertical extent of the ozone profiles is improved by combining both wavelength ranges compared to retrievals limited to UV or IR spectral data only. The combined retrieval particularly improves the accuracy of the retrieved tropospheric ozone and to a lesser degree stratospheric ozone up to 30 km. An increase in the degrees of freedom (DOF) by 1 DOF was found in the UV + IR retrieval compared to the UV-only retrieval. Compared to previous publications, which investigated combinations of UV and IR observations from the Ozone Monitoring Instrument and Tropospheric Emission Spectrometer (OMI and TES) and Global Ozone Monitoring Experiment version 2 and Infrared Atmospheric Sounding Interferometer (GOME-2 and IASI) pairs, the degree of freedom is lower, which is attributed to the reduced spectral resolution of CrIS compared to TES or IASI. Tropospheric lidar and ozonesondes were used to validate the ozone profiles and tropospheric ozone content (TOC). In their comparison with tropospheric lidars, both ozone profiles and TOCs show smaller biases for the retrieved data from the combined UV + IR observation than from the UV observations alone. For the ozone profiles below 10 km, the mean differences are around ±10 % and the mean TOC varies around ±3 DU. We show that TOCs from the combined retrieval agree better with ozonesonde results at northern latitudes than the UV-only and IR-only retrievals and also have lower scatter. In the tropics, the IR-only retrieval shows the best agrement with TOCs derived from ozonesondes. While in general the TOCs show good agreement with ozonesonde data, the profiles have a positive bias of around 30 % between 10 and 15 km. The reason is probably a positive stratospheric bias from the IR retrieval. The comparison of the UV + IR and UV ozone profiles up to 30 km with the Microwave Limb Sounder (MLS) demonstrates the improvement of the UV + IR profile in the stratosphere above 18 km. In comparison to the UV-only approach the retrieval shows improvements of up to 10 % depending on latitude but can also show worse results in some regions and latitudes.

Ozone↗

Global Fine Scale Changes in Ambient NO2 During COVID-19 Lockdowns

Nitrogen dioxide (NO2) is an important contributor to air pollution and can adversely affect human health(1–9) . A decrease in NO2 concentrations has been reported as a result of lockdown measures to reduce the spread of COVID-19(10–20). Questions remain, however, regarding the relationship of satellite-derived atmospheric column NO2 data with health-relevant ambient ground-level concentrations, and the representativeness of limited ground-based monitoring data for global assessment. Here we derive spatially resolved, global ground-level NO2 concentrations from NO2 column densities observed by the TROPOMI satellite instrument at sufficiently fine resolution (approximately one kilometre) to allow assessment of individual cities during COVID-19 lockdowns in 2020 compared to 2019. We apply these estimates to quantify NO2 changes in more than 200 cities, including 65 cities without available ground monitoring, largely in lower-income regions. Mean country-level population-weighted NO2 concentrations are 29% ± 3% lower in countries with strict lockdown conditions than in those without. Relative to long-term trends, NO2 decreases during COVID-19 lockdowns exceed recent Ozone Monitoring Instrument (OMI)-derived year-to-year decreases from emission controls, comparable to 15 ± 4 years of reductions globally. Our case studies indicate that the sensitivity of NO2 to lockdowns varies by country and emissions sector, demonstrating the critical need for spatially resolved observational information provided by these satellite-derived surface concentration estimates.

Ground level NO2↗

High‐Resolution Mapping of Nitrogen Dioxide With TROPOMI: First Results and Validation Over the Canadian Oil Sands

TROPOspheric Monitoring Instrument (TROPOMI), on-board the Sentinel-5 Precursersatellite, is a nadir-viewing spectrometer measuring reflected sunlight in the ultraviolet, visible,near-infrared, and shortwave infrared. From these spectra several important air quality and climate-relatedatmospheric constituents are retrieved, including nitrogen dioxide (NO2) at unprecedented spatialresolution from a satellite platform. We present the first retrievals of TROPOMI NO2over the Canadian OilSands, contrasting them with observations from the Ozone Monitoring Instrument satellite instrument,and demonstrate TROPOMI's ability to resolve individual plumes and highlight its potential for derivingemissions from individual mining facilities. Further, the first TROPOMI NO2validation is presented,consisting of aircraft and surface in situ NO2observations, and ground-based remote-sensingmeasurements between March and May 2018. Our comparisons show that the TROPOMI NO2verticalcolumn densities are highly correlated with the aircraft and surface in situ NO2observations, and theground-based remote-sensing measurements with a low bias (15–30 %); this bias can be reduced byimproved air mass factors. Plain Language Summary: Nitrogen dioxide (NO2) is a pollutant that is linked to respiratoryhealth issues and has negative environmental impacts such as soil and water acidification. Near thesurface the most significant sources of NO2are fossil fuel combustion and biomass burning. With a recentlylaunched satellite instrument (TROPOspheric Monitoring Instrument [TROPOMI]), NO2can be measuredwith an unprecedented combination of accuracy, spatial coverage, and resolution. This work presents thefirst TROPOMI NO2measurements near the Canadian Oil Sands and shows that these measurements havean outstanding ability to detect NO2on a very high horizontal resolution that is unprecedented for satelliteNO2observations. Further, these satellite measurements are in excellent agreement with aircraft andground-based measurements.

TROPOspheric Monitoring Instrument (TROPOMI)↗

Verification of TROPOMI NO2 Product Using OMI NO2 algorithm

We evaluated S5P TROPOspheric Monitoring Instrument (TROPOMI) operational nitrogen dioxide (NO2) product by comparing with the NO2 retrievals from Ozone Monitoring Instrument (OMI) onboard NASA’s Aura satellite. We compared spatially matched NO2 vertical column density (VCD) data from OMI and TROPOMI to identify any discrepancies between the two operational products. We also applied OMI Air-Mass Factor (AMF) algorithm to TROPOMI Slant Column Density (SCD) data (v02.03.01) aiming to create long-term merged NO2 Earth Science Data Record (https://disc.gsfc.nasa.gov/datasets/TROPOMI_MINDS_NO2_1.1/summary ). The algorithm (version 4.0) uses new Geometry-dependent Lambertian Equivalent surface Reflectivity (GLER) product available for each TROPOMI pixel. GLER is pre-calculated using the vector linearized discrete ordinate radiative transfer (VLIDORT) model, which uses as input high-resolution bidirectional reflectance distribution function (BRDF) information from NASA's Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) over land and the wind-dependent Cox–Munk wave-facet slope distribution over water, the latter with a contribution from the water-leaving radiance based on MODIS gap-filled in-water chlorophyll-a data. The GLER data, combined with consistently retrieved cloud parameters, provide improved information for the calculation of the scattering weight profiles. Additional AMF improvements result from using high resolution (0.25o latitude x 0.25o longitude) a priori NO2 profile shapes and other auxiliary information from the Global Modeling Initiative (GMI) Replay simulation sampled using S5P orbital simulator. Our TROPOMI_MINDS_NO2 algorithm employs the stratosphere-troposphere separation scheme, de-striping, and surface snow/ice treatment consistently with the latest OMI NO2 re-processing (version 4). We evaluate the TROPOMI_MINDS_NO2 product by comparing with the S5P operational NO2 product as well as with independent NO2 observations from ground-based Pandora and aircraft observations. Our results indicate that the new TROPOMI_MINDS_NO2 retrievals are generally higher than the S5P operational NO2 product over polluted regions and show improved agreement with independent validation data.

TROPOMI↗