Engineering topics
Percher, Catherine
Publications and source records attributed to Percher, Catherine.
The Completion of Surrogate Testing for Low-Temperature TEX and a Look Towards the Future
To address the mounting need for below room temperature nuclear data validation, the Low-Temperature Thermal Epithermal eXperiments (LT-TEX) have been designed. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University.
TEX-HEU: Integral Experiment Execution with Polyethylene at Very Low Temperatures
The low-temperature variant of the TEX HEU (called Low-Temperature TEX or sometimes LT TEX) campaign is a highly anticipated and necessary experimental series by the greater nuclear science community. Fundamentally, the need for low-temperature integral experiments is required to perform validation of cross sections below room temperature. There has been substantial international interest in low-temperature benchmarks to validate below room temperature cross sections, namely talks given at the 2019 International Conference on Nuclear Criticality (ICNC): UK (Watson, 2019), France (Milin, 2019), and UK (Gan & Wilson, 2019). Additionally, NCSP funded thermal scattering laws (TSLs) were produced by North Carolina State University and require low-temperature benchmarks to validate them. Validation of low-temperature cross sections is also necessary for criticality safety applications. One particularly important application is to ensure that during transportation, fissile materials must remain subcritical under normal ambient conditions which is defined as temperatures down to -40°C/°F by the United States 10 CRF 71 as well as a regulation put forward by the International Atomic Energy Agency (IAEA).
Experiment Logistics for an International Blind Intercomparison Exercise for Nuclear Accident Dosimetry at the Armed Forces Radiobiology Research Institute's TRIGA Reactor
This document is the Experimental Set-up and Design (CED-3a) Report for IER-602, “Dosimetry Exercise with Armed Forces Radiobiology Research Institute (AFRRI) - Exercise” The report discusses the structure of the exercise consisting of three reactor exposures, identifying the participating laboratories and their points of contact. The report also includes details of all dosimetry each laboratory will submit to be placed in proximity to AFRRI on aluminum plates or BOMAB phantoms. Each laboratory lists the counting and spectroscopy equipment to be utilized at AFFRI. The exercise is tentatively scheduled for one week in June, 2024 (FY24 Q4).
IER-580 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experiments (PNDA) with H 2 O
This report summarizes new experiments performed with H 2 O for IER-580, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The experiments will become high-quality benchmarksthat serve to optimize and validate thermal neutron scattering laws (TSLs) of H 2 O, which are high-priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). The report presents the details of the measurements conducted in October of 2023, including the experimental set-up (PNDA equipment and H 2 O targets) and all experimentally measured data. The report gives the fitted decay constants for the die-away curves of each target sample. It also provides the tabulated data for the die-away curves in the appendices.
LLNL IPD Tasks: ICSBEP and Pulsed Spheres Benchmark [Slides]
This lecture presented benchmark of the blank and polyethylene spheres at SINBAD in April 2023. In responding to comments about the building, we uncovered a large amount of additional detailed information about the building and experimental set up. We incorporated this new information into an even higher fidelity model and are working on uncertainty analysis at a low level. Scheduled to present at SINBAD meeting in April 2024.
IER-479/547: Low-Temperature TEX Surrogate Testing and Reflector Design [Slides]
This lecture includes a look into progress in surrogate testing. This includes a new chiller that has been fabricated and testing that has resumed. Additional tests are being conducted, including: using formed aluminum gaskets, extended testing with natural uranium, testing with pseudo-spindle, testing with no vacuum. This lecture includes a look into the Reflector Design. Results for detailed model are consistent with results presented in CED-2. Calculations provide flexibility in the physical design of the reflectors (e.g. reflector segment widths and heights). Provided initial CAD models of reflector components.
IER-499 Final Design of a TEX Variant: Chlorine to Support NNSA Operations [Slides]
This presentation concludes the final design of TEX with chlorine absorbers is complete. 5 configurations were identified, expected to down select to three experimental configurations. Great comparison to Y-12 and good comparison to INL sensitivities. Fastest configuration touches on the 35 Cl(n,p) cross section (continuing to work with Terrapower for faster configurations). Extensive density studies performed to ensure understanding of the salt in the plates. Reactivity studies performed to assist with experiment. Finally, the fabrication of the chlorine absorbers is ongoing (with LANL), and the experiment is scheduled to be completed this year.
IER 480: TEX-Pu Benchmark (PU-MET-THERM-004) to Test Polyethylene and Lucite Thermal Scattering Laws [Slides]
This presentation finds that PMT-004 has four new benchmark cases highly sensitive to PE TSL (2 cases) and PMMA TSL (2 Cases). PE cases were well predicted using MCNP6.2 and ENDF/B-VIII.0. PMMA cases overpredicted by approximately 0.6-0.7% in k eff at 20°C. Accepted into 2023 version of the ICSBEP Handbook. Temperature had a large impact on reactivity of the critical configuration. Implications for validation work for thermal cases- need to adjust TSL data to correct temperature as it can have hundreds of pcm effects for a few °C. Future thermal experiments should try and measure reactivity at multiple temperatures to aid in data testing and benchmark adjustment.
Chlorine Validation through Critical Integral Experiments
An increased interest in the validation of chlorine nuclear data, specifically 35Cl, in recent years has led to the prioritization of conducting chlorine critical experiments for nuclear data validation and criticality safety evaluations. A previous experiment was conducted with PVC and CPVC (chlorinated polyvinyl chloride) to reduce the margin of subcriticality for PF-4 operations with aqueous plutonium chloride solutions. Challenges in determining the composition of specific polymers, namely the CPVC, made it difficult to characterize, and therefore benchmark. Additional materials that were utilizable for chlorine validation were not immediately clear, as form, strength, purity, and composition are all important. A series of possible absorber materials were identified and studied, but ultimately granular sodium chloride was chosen. In addition to the needs of LANL’s PF-4 other industry collaborators have brought attention to the need for chlorine validation. Specifically, the need for HEU electrorefining with LiCl salts at Y-12 was taken into consideration for this experiment, with the experimental configurations being finely tuned to best meet their needs. Needs for validation were also presented by Idaho National Lab (INL) and TerraPower for validation of their Molten Chloride Reactor Experiment (MCRE) and Molten Chloride Fast Reactor (MCFR) and have also been considered.
IER-479/547: Low-Temperature TEX Final Design and Surrogate Measurements [Slides]
This presentation covers the final design, and measurements of the Low-Temperature TEX. Visual Diagrams of the apparatus and detailed part explanations are included. Neutronic calculations for Low-Temperature TEX was performed. Six configurations were proposed. Thermal analysis for the boundary cases was performed. Thermal testing with surrogate materials has been underway and testing will resume shortly.
Progress Towards the Reality of Low-Temperature Critical Experiments with Low-Temperature TEX
Integral benchmarks for criticality safety do not exist below room temperature. Incredible support for below room temperature benchmarks is present across the international community. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Similarly, the IAEA, which contains 176 member states, has the same requirement for subcriticality for fissile material transportation. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University. A six-case experiment designed based off the TEX-HEU baseline experiments has been proposed utilizing a chilled vacuum chamber capable of cooling the HEU stack down to -50°C. The six proposed configurations span the entire neutron fission energy range and can be tested at intermediate temperatures between room temperature and -40°C. Of the six configurations, the fastest case utilizes nearly 135 kg of HEU. Understanding the system is required prior to critical experiment operations. In order to test the functionality of the system, testing with surrogate fuel materials has been conducted. The following discusses the design of the low temperature TEX (LT-TEX) experiment as well as the progress made via surrogate testing towards a reality in which low-temperature integral benchmarks exist in the International Criticality Safety Benchmark Evaluation Project (ICSBEP).
Final Design for Thermal/Epithermal eXperiments (TEX) with Chloride Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility
Uranium electrorefining operations at Y-12 require validation for chlorine absorption and reflection. Plutonium chloride solution operations at Los Alamos National Laboratory require chlorine absorption validation. The growing need for chlorine validation is evident to the wider criticality safety community, with multiple attendees at the recent TEX 2.0 meeting at Lawrence Livermore National Laboratory (May 2023) requesting validation for chlorine (Idaho National Laboratory (INL), Institute de radioprotection et de surete nucleaire (IRSN), Savannah River Nuclear Site (SRNS), LANL, and Y-12). Los Alamos National Laboratory has recently performed, and benchmarked, an experiment titled Chlorine Worth Study (CWS) for the internal operations at the lab, but due to the difficulties in precisely characterizing the material compositions of the chlorine absorbers it is advantageous to perform a complimentary study with a different chlorine-based absorber material. Furthermore, having a uranium-based vs plutonium-based experiment provides a separate and important validation basis for criticality safety and nuclear data evaluation. The original final design report for the study of chlorine absorption using the TEX-HEU experimental base was presented in 2022, but used the same chlorine-bearing materials that were found to be difficult to characterize in the LANL benchmark. A complete redesign of the experiment has been performed looking at alternative absorber materials in various forms to produce an experiment that is fully characterizable. This report presents five novel chlorine experiments using the TEX-HEU test bed which provides direct comparison to the Y-12 and INL/Terrapower application needs, utilizing sodium chloride (NaCl) absorber plates. The absorber plates will consist of granulated NaCl (≥99.5% pure), which will be fully encapsulated in aluminum tins, providing a simple but effective chlorine-based absorber material that can be completely characterized. Of the five configurations presented in this report, it is expected that two or three configurations will be down selected for the actual experiment, with the other configurations being alternates. Three of the configurations are in the standard configuration, where the absorber is placed directly on the HEU fuel plates, and two in the sandwich configuration, where the absorber is surrounded by polyethylene moderators to force additional neutron thermalization prior to reaching the absorber. There are two thicknesses of NaCl absorber plates: 3/16” and 1/4” active thicknesses (i.e. not including the encapsulation). Both variations of the absorbers have an active absorber radius of 6” and a total radius of 7.5” to match the diameter of the HEU plates, with the outer 1.5” being aluminum encapsulation. The high-density polyethylene (HDPE) moderators are of the thicknesses: 27/16”, 7/4”, 1/8”, 11/16”, and 3/4”. The final configurations have six (one sandwich and one standard configuration), eight (one sandwich and one standard configuration), and 18 total fuel layers (standard configuration). The standard and sandwich configurations were designed such that the differences in moderator thicknesses are 1” HDPE, which were already procured for the original CED-2. The proposed configurations were precisely tuned to closely match the sensitivity profiles and neutron spectra of the Y-12 upset cases and were also compared to the INL/Terrapower upset cases. The assessment of experimental uncertainties of the non-absorber components was predicted to be 0.00114 Δk eff . The assessment of uncertainties resulting from the absorbers was predicted to be 0.00029 Δk eff . This results in a total uncertainty of 0.00118 Δk eff . Many of the largest uncertainties, namely the moderator densities, may be reduced with precision dimensional inspection of the components. The 1” HDPE moderators as well as the HDPE reflectors from the original CED-2 were incorporated in the final designs presented here. Additional HDPE moderator plates must be fabricated to complete the configurations. NaCl absorber plates will by fabricated at LLNL. The total additional cost is expected to be $\$$54,250 for the remaining components. Precise inspection, including dimensional, mass, density, and impurity, is recommended for all components. LLNL estimates that these costs are around $\$$12,000. It is expected, based on previous TEX-HEU experiments, that three weeks of experimental facility time is needed to complete the experiments.
AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results
Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.
Gamma-ray Measurements from Neutron Pulsed Die-Away Experiments
Pulsed-neutron die-away experiments are a promising experimental method that complement criticality benchmarks for nuclear data validation. The experiments have several advantages that include compatibility with non-fissile material, low benchmark uncertainties, and high sensitivity to absorption and scattering cross sections. When validating thermal neutron scattering laws, small targets are desirable for their large sensitivity to the scattering cross section and angular distribution. Unfortunately, room return or scattering from a shielding box limits the use of the very small targets needed to maximize sensitivity to thermal scattering laws. To address this problem, we propose changing the observable of the experiment from leaked thermal neutrons to γ-rays produced by (n, γ) reactions in the target. If feasible, this change allows removal of the shielding box, achieving higher sensitivity to thermal neutron scattering laws. This study focuses on replicating benchmark pulsed-neutron die-away experiments with γ-rays. We compare the integral parameters with γ-rays to those obtained with neutrons. We also discuss experimental design choices such as detector placement, shielding, and the presence of Cd. The results show the integral parameter with γ-rays is sensitive to detector location with respect to the target when Cd shielding is present. In addition, while Pb shielding around the γ-ray detectors do not seem to affect the integral parameter, the presence of Cd shielding does and adds background γ-rays to the die-away curves making it difficult to calculate the integral parameter.
Towards an Era of Low-Temperature Integral Critical Experiments: Surrogate Testing of Low-Temperature TEX Configurations
United States and IAEA regulations for the transportation of radioactive materials require that fissile materials must be subcritical under expected ambient temperatures ranging from -40°C to 38°C. While historical experiments have been conducted at room and elevated temperatures, no criticality integral benchmarks exist for temperatures below room temperature. The Low-Temperature Thermal Epithermal eXperiments (LT-TEX) aim to provide benchmark evaluations down to -40°C. The LT-TEX design incorporates stacked HEU plates interspersed with varying thicknesses of polyethylene disks to provide varying levels of moderation, with five configurations at 20°C having already been benchmarked. A novel vacuum/cryogenic chamber was fabricated to contain the LT-TEX configurations in a thermally isolated environment and cool it to -40°C. Prior to testing with fissile materials, testing with surrogate fuel plates was performed to characterize the thermal properties of the system, ensure no condensation forms on the stack, and to test that the uranium plates would not warp, or fracture during the thermal cycling. Surrogate testing has characterized the cryogenic chamber and verified its viability to perform the benchmark experiments, allowing for the next steps in the LT-TEX experimental campaign. The results of the surrogate testing are discussed and compared to heat transfer calculations performed as part of the experiment design process, to establish confidence in the thermal behavior of the system.
Godiva-IV Dosimetry Exercise 2022 Preliminary Results
Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.