Search NASA⌕ Search

Engineering topics

Perek, A. (ORCID:0000000241170298)

Publications and source records attributed to Perek, A. (ORCID:0000000241170298).

Systematic multi-machine analysis of the exhaust time-dependent behavior in tokamaks

The understanding of the time-scales and associated transient behavior of fusion exhaust plasmas plays a crucial role in its dynamic modeling and its control. This work presents an overview of experimental investigations of the exhaust dynamics in TCV, MAST-U, ASDEX-Upgrade, WEST, DIII-D, and JET. From the presented experiments, a clear picture arises on properties of the exhaust dynamics across machines. Particularly, we observe that the scrape-off layer equilibrates on fast time-scales ($>$ 70 Hz) and that exhaust dynamics measured in response to gas valve modulations mostly behave smoothly and linearly, with similarities across devices, across scenarios (H-mode, L-mode), injected species, and injection locations. The measurements presented have formed the basis for systematic exhaust control on the considered devices. We now present this database for the essential validation of dynamic exhaust models for reactor design and control.

control↗

Comparison of detachment in Ohmic plasmas with positive and negative triangularity

Abstract In recent years, negative triangularity (NT) has emerged as a potential high-confinement L-mode reactor solution. In this work, detachment is investigated using core density ramps in lower single null Ohmic L-mode plasmas across a wide range of upper, lower, and average triangularity (the mean of upper and lower triangularity: δ ) in the TCV tokamak. It is universally found that detachment is more difficult to access for NT shaping. The outer divertor leg of discharges with δ ≈ − 0.3 could not be cooled to below 5 eV through core density ramps alone. The behavior of the upstream plasma and geometrical divertor effects (e.g. a reduced connection length with negative lower triangularity) do not fully explain the challenges in detaching NT plasmas. Langmuir probe measurements of the target heat flux widths ( λ q ) were constant to within 30% across an upper triangularity scan, while the spreading factor S was lower by up to 50% for NT, indicating a generally lower integral scrape-off layer width, λ int . The line-averaged core density was typically higher for NT discharges for a given fuelling rate, possibly linked to higher particle confinement in NT. Conversely, the divertor neutral pressure and integrated particle fluxes to the targets were typically lower for the same line-averaged density, indicating that NT configurations may be closer to the sheath-limited regime than their PT counterparts, which may explain why NT is more challenging to detach.

Physics↗

Validation of 2D Te and ne measurements made with Helium imaging spectroscopy in the volume of the TCV divertor

Abstract Multi-spectral imaging of helium atomic emission (HeMSI) has been used to create 2D poloidal maps of T e and n e in TCV’s divertor. To achieve these measurements, TCV’s MANTIS multispectral cameras (Perek et al 2019 Rev. Sci. Instrum. 90 123514) simultaneously imaged four He I lines (two singlet and two triplet) and a He II line (468 nm) from passively present He and He + . The images, which were absolutely calibrated and covered the whole divertor region, were inverted through the assumption of toroidal symmetry to create emissivity profiles and, consequently, line-ratio profiles. A collisional-radiative model (CRM) was applied to the line-ratio profiles to produce 2D poloidal maps of T e and n e . The collisional-radiative modeling was accomplished with the Goto helium CRM code (Zholobenko et al 2018 Nucl. Fusion 58 126006, Zholobenko et al 2018 Technical Report , Goto 2003 J. Quant. Spectrosc. Radiat. Transfer 76 331–44) which accounts for electron-impact excitation (EIE) and deexcitation, and electron–ion recombination (EIR) with He + . The HeMSI T e and n e measurements were compared with co-local Thomson scattering measurements. The two sets of measurements exhibited good agreement for ionizing plasmas: ( 5 eV ⩽ T e ⩽ 60 eV , and 2 × 10 18 m − 3 ⩽ n e ⩽ 3 × 10 19 m − 3 ) in the case of majority helium plasmas, and ( 10 eV ⩽ T e ⩽ 40 eV , 2 × 10 18 m − 3 ⩽ n e ⩽ 3 × 10 19 m − 3 ) in the case of majority deuterium plasmas. However, there were instances where HeMSI measurements diverged from Thomson scattering. When T e ⩽ 10 eV in majority deuterium plasmas, HeMSI deduced inaccurately high values of T e . This disagreement cannot be rectified within the CRM’s EIE and EIR framework. Second, on sporadic occasions within the private flux region, HeMSI produced erroneously high measurements of n e . Multi-spectral imaging of Helium emission has been demonstrated to produce accurate 2D poloidal maps of T e and n e within the divertor of a tokamak for plasma conditions relevant to contemporary divertor studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New insights on divertor parallel flows,E × B drifts, and fluctuations from in situ, two-dimensional probe measurement in the Tokamak à Configuration Variable

Abstract In situ , two-dimensional (2D) Langmuir probe measurements across a large part of the TCV outer divertor are reported in L-mode discharges with and without divertor baffles. This provides detailed insights into time averaged profiles, particle fluxes, and fluctuation behavior in different divertor regimes. The presence of the baffles is shown to substantially increase the divertor neutral pressure for a given upstream density and to facilitate the access to detachment, an effect that increases with plasma current. The detailed, 2D probe measurements allow for a divertor particle balance, including ion flux contributions from parallel flows and E × B drifts. The poloidal flux contribution from the latter is often comparable or even larger than the former, and the divertor parallel flow direction reverses in some conditions, pointing away from the target. In most conditions, the integrated particle flux at the outer target can be predominantly ascribed to ionization along the outer divertor leg, consistent with a closed-box approximation of the divertor. The exception is a strongly detached divertor, achieved here only with baffles, where the total poloidal ion flux even decreases towards the outer target, indicative of significant plasma recombination. The most striking observation from relative density fluctuation measurements along the outer divertor leg is the transition from poloidally uniform fluctuation levels in attached conditions to fluctuations strongly peaking near the X-point when approaching detachment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗