Perez, P

Publications and source records attributed to Perez, P.

Developing and improving a scanning system for dosimetric applications

Radiotherapy is nowadays one of the most used techniques for the treatment of different pathologies, particularly cancer diseases. The accuracy regarding the application of these treatments, which are planned according to patient information, depends mainly on the dosimetric measurements of absorbed dose within irradiated tissues. The present work is devoted to the study, design and construction of an original device capable of performing visible light transmission measurements in order to analyze Fricke gel dosimeters. Furthermore, a suitable bi-dimensional positioning system along with a dedicated control system and image processing software has been adapted to the dosimetric device in order to perform 2D dose mapping. The obtained results confirm the feasibility of the proposed method, therefore suggesting its potentiality for clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D dose and TCP distribution for radionuclide therapy in nuclear medicine

A common feature to any radiant therapy is that lesion and health tissue dosimetry provides relevant information for treatment optimization along with dose-efficacy and dose-complication correlation studies. Nowadays, different radionuclide therapies are commonly available, assessing both systemic and loco-regional approach and using different alfa-, beta-and gamma-emitting isotopes and binding molecules. It is well established, that specific dosimetric approaches become necessary according to each therapy modality. Sometimes, observed activity distribution can be satisfactory represented by simple geometrical models. However, Monte Carlo techniques are capable of better approaches, therefore becoming sometimes the only way to get dosimetric data since the patient-specific situation can not be adequately represented by conventional dosimetry techniques. Therefore, due to strong limitations of traditional and standard methods, this work concentrates on the development of a dedicated and novel calculation system in order to assess the dose distribution within the irradiated patient. However, physical dose may not be enough information in order to establish real deterministic biological/metabolic effects; therefore complementary radiobiological models have been suitably introduced with the aim of performing realistic 3D dose as well as corresponding Tumor Control Probability distribution calculation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Positronium cooling in porous silica measured via Doppler spectroscopy

We have measured the kinetic energy of positronium (Ps) atoms emitted into a vacuum from a porous silica film subsequent to positron bombardment, via the Doppler spread of the linewidth of the Ps 1{sup 3}S-2{sup 3}P transition. We find that the deeper in the target film that positrons are implanted the colder is the emitted Ps, an effect we attribute to cooling via collisions in the pores as the atoms diffuse back to the film surface. We observed a lower limit to the mean Ps kinetic energy associated with motion in the direction of the laser, E{sub x}=42+-3 meV, that is consistent with conversion of the confinement energy of Ps in the 2.7-nm-diameter pores to kinetic energy in vacuum. An implication is that a porous sample would need to be composed of pores greater than around 10 nm in diameter in order to produce thermal Ps in vacuum with temperatures of less than 100 K. By performing Doppler spectroscopy on intense pulses of Ps we have experimentally demonstrated the production of many excited-state Ps atoms simultaneously, which could have numerous applications, including laser cooling and fundamental spectroscopic studies of Ps and the production of antihydrogen.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Mini Linac Based Positron Source at CEA-Saclay

We are installing at CEA-Saclay a demonstration setup for an intense positron source. It is based on a compact 5.5 MeV electron linac used to produce positrons via pair production on a tungsten target. A relatively high current of 0.15 mA compensates for low positron efficiencies at low energy, which is below the neutron activation threshold. The expected production rate is 5centre dot10{sup 11} fast positrons per second. A set of coils is arranged to select the fast positrons from the diffracted electron beam in order to study the possibility of using a rare gas cryogenic moderator away from the main flux of particles. The commissioning of the linac is under way. This setup is part of a project to demonstrate the feasibility of an experiment to produce the H{sup +} ions for a free fall measurement of neutral antihydrogen (H). Its small size and cost could be of interest for material science applications, after adaptation of the time structure.

43 PARTICLE ACCELERATORS↗