Search NASA⌕ Search

Engineering topics

Perry, Theodore Sonne

Publications and source records attributed to Perry, Theodore Sonne.

FY2024 Q4 L2 Milestone 8237 for Opacity-on-NIF

This document addresses parts 2 and 3 of the original milestone request. In the following writeup, the development of OpSpecTR at LLNL by LLNL and NNSS personnel will be detailed first, followed by a write-up of the development of Vme-resolved simulaVons of the opacity-on-NIF experiment. Capsule backlight simulaVons, hohlraum simulaVons, and sample simulaVons from CASSIO are combined to produce the line of sight from the capsule to an effecVve OpSpec posiVon. Spectra are generated by post-processing these simulaVons from either Spect3D, a commercial software by Prism ComputaVonal Sciences, or FESTR (Finite Element Spectroscopic Transport of RadiaVon), a LANL code. While the simulaVons do not at this stage proceed late enough to include the worst of the backgrounds generated from the hohlraum experimentally and each post-processing simulaVon includes only one ray for each spectrometer channel, these efforts represent proof of concept for a new capability to complete Vme-resolved and Vmegated simulaVons for the complete line of sight of the complex opacity-on-NIF geometry. Future work will be discussed at the end of the report for both efforts.

42 ENGINEERING↗

Relative sensitivity of plastic scintillator: A comparative analysis with 60 Co gamma rays, deuterium–deuterium, and deuterium–tritium neutrons

A plastic scintillator has found extensive application in the realm of high-energy physics and national security science. Many applications in those fields often involve the simultaneous production of photons, neutrons, and charged particles, which makes the relative sensitivity information for these different radiation types important. In this study, we have adopted a multi-head detector comprised of a plastic scintillator and high gain phototubes, which provides a large dynamic range and linearity. A comparative study on the relative sensitivities of plastic scintillators was facilitated by adopting three distinct radiation calibration sources (i.e., 60 Co γ rays, DD neutrons, and DT neutrons). Neutrons from a DD source generate a comparable level of scintillation to gamma rays emitted by 60 Co (i.e., 60 Co-γ/DD-n = 0.92 ± 16%). DT neutrons induce ~3.5 times the scintillation observed with DD neutrons (i.e., DT-n/DD-n = 3.5 ± 28%). In addition, the Geant4 simulation granted us valuable insights into the relative sensitivity of the scintillator. This comparative study will provide a useful database for users in diverse applications.

47 OTHER INSTRUMENTATION↗