SU-C-201-05: Silicon Array Dosimeter in Situ with Electronic Portal Image Device for Simultaneous Transit Dose and Image Verification in Radiotherapy

Purpose: To investigate an Electronic Portal Imaging Device (EPID) coupled to a 2D array dosimeter to provide simultaneous imaging and dose verification. Methods: The novel dual detector configuration comprised of a 2D diode array dosimeter, referred to as a Magic Plate (MP) placed directly on a standard EPID. Dose response of the MP was evaluated by measuring the detector’s response with respect to off-axis position and field size with 30 cm of solid water (SW) acting as a transit object in the beam. Measurements were performed with 3, 5, 10 and 15 mm SW build-up and compared to 2D ionisation chamber array (ICA) measurements and the PinnacleTM treatment planning system (TPS) at a source to detector distance of 150 cm with a 6 MV beam. Clinical dosimetric performance was evaluated by measuring a number of intensity-modulated radiation therapy (IMRT) beams in transit geometry. Imaging performance of the EPID was quantified by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of a Rando phantom were used for qualitative assessment. Results: Measured MP off-axis and field size response agreed within 2% of TPS and ICA responses when measured using 15 mm SW build-up. Clinical IMRT beams had gamma pass rates of ≥95% at 3%/3mm criteria. Measured CNR and spatial resolution (f50) were 264.96, 210.6, and 0.41, 0.40 with build-up of 5 and 15 mm respectively for the dual detector configuration. CNR and spatial resolution of 643.9 and 0.41 were measured for standard EPID. CNR was quantitatively worse in the dual detector configuration. Differences in imaging performance were not visible in a qualitative assessment using a Rando phantom. Conclusion: Combining a prototype MP 2D dosimeter with a conventional EPID did not significantly detract from the performance of either device and has the potential for simultaneous on-line patient transit dosimetry and image assessment in radiation therapy. Cancer Institute NSW Australia(Research Equipment Grant 10/REG/1-20) and Cancer Council NSW (Grant ID RG 1-06)

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-04: A Novel Monolithic Silicon 2D Detector Array for Use in Stereotactic Applications

Purpose: To assess the capability of a novel 2D monolithic silicon detector array in measuring stereotactic photon fields. Methods: The silicon array detector used in this work, named Magic Plate-512 (MP512), is a thin monolithic silicon wafer (52 × 52 × 0.47 mm{sup 3}) with 512 ion-implanted diodes (0.5 × 0.5 mm{sup 2}). Adjacent pixels are spaced evenly with 2 mm pitch, covering a maximum detection area 46 mm wide. Its fast, FPGA based read-out system is synchronised with the linac to allow readout of all pixels pulse-by-pulse. A clinical SABR lung plan (consisting of 9 single segment beams, 6MV) was measured with the array at 1.5 cm depth in a solid water phantom (100 cm SSD). The typical field size was in the range of 3 × 3 cm{sup 2} to 4 × 4 cm{sup 2}. Each beam was delivered at perpendicular incidence to the detector plane so as to avoid the need for angular dependence corrections. The fields were measured under the same conditions using Gafchromic EBT3 film for comparison. The film was scanned at 72 dpi resolution, with the red channel data used for analysis. Results: Average gamma passing rates of (92.3 ± 1.8) % for 2%/2mm criteria, and (86.6 ± 2.3) % for 1%/2mm criteria were achieved for MP512, using EBT3 film as the reference distribution. The detector array was able to accurately measure the full-width-at-half-maximum (FWHM), to within (0.77 ± 0.01) mm accuracy when compared to film. The penumbral widths (80%-20%) were measured to within (0.30 ± 0.01) mm accuracy to film. Conclusion: The MP512 is a feasible option for measurement of stereotactic photon fields, with its high density of detection points making it useful for small field applications. The prototype array has demonstrated merit; in the future the development of a larger array detection area would be beneficial for clinical applications.

60 APPLIED LIFE SCIENCES↗

Potential High Resolution Dosimeters For MRT

Microbeam Radiation Therapy (MRT) uses highly collimated, quasi-parallel arrays of X-ray microbeams of 50-600 keV, produced by 2nd and 3rd generation synchrotron sources, such as the National Synchrotron Light Source (NSLS) in the U.S., and the European Synchrotron Radiation Facility (ESRF) in France, respectively. High dose rates are necessary to deliver therapeutic doses in microscopic volumes, to avoid spreading of the microbeams by cardiosynchronous movement of the tissues. A small beam divergence and a filtered white beam spectrum in the energy range between 30 and 250 keV results in the advantage of steep dose gradients with a sharper penumbra than that produced in conventional radiotherapy. MRT research over the past 20 years has allowed a vast number of results from preclinical trials on different animal models, including mice, rats, piglets and rabbits. Microbeams in the range between 10 and 100 micron width show an unprecedented sparing of normal radiosensitive tissues as well as preferential damage to malignant tumor tissues. Typically, MRT uses arrays of narrow ({approx}25-100 micron-wide) microplanar beams separated by wider (100-400 microns centre-to-centre, c-t-c) microplanar spaces. We note that thicker microbeams of 0.1-0.68 mm used by investigators at the NSLS are still called microbeams, although some invesigators in the community prefer to call them minibeams. This report, however, limits it discussion to 25-100 {mu}m microbeams. Peak entrance doses of several hundreds of Gy are surprisingly well tolerated by normal tissues. High resolution dosimetry has been developed over the last two decades, but typical dose ranges are adapted to dose delivery in conventional Radiation Therapy (RT). Spatial resolution in the sub-millimetric range has been achieved, which is currently required for quality assurance measurements in Gamma-knife RT. Most typical commercially available detectors are not suitable for MRT applications at a dose rate of 16000 Gy/s, micron resolution and a dose range over several orders of magnitude. This paper will give an overview of all dosimeters tested in the past at the ESRF with their advantages and drawbacks. These detectors comprise: Ionization chambers, Alanine Dosimeters, MOSFET detectors, Gafchromic registered films, Radiochromic polymers, TLDs, Polymer gels, Fluorescent Nuclear Track Detectors (Al{sub 2}O{sub 3}:C, Mg single crystal detectors), OSL detectors and Floating Gate-based dosimetry system. The aim of such a comparison shall help with a decision on which of these approaches is most suitable for high resolution dose measurements in MRT. The principle of these detectors will be presented including a comparison for some dosimeters exposed with the same irradiation geometry, namely a 1x1 cm{sup 5} field size with microbeam exposures at the surface, 0.1 cm and 1 cm in depth of a PMMA phantom. For these test exposures, the most relevant irradiation parameters for future clinical trials have been chosen: 50 micron FWHM and 400 micron c-t-c distance. The experimental data are compared with Monte Carlo calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗