Toxicological Assessment of the International Space Station Atmosphere with Emphasis on Metox Canister Regeneration

Space-faring crews must have safe breathing air throughout their missions to ensure adequate performance and good health. Toxicological assessment of air quality depends on the standards that define acceptable air quality, measurements of pollutant levels during the flight, and reports from the crew on their in-flight perceptions of air quality. Air samples returned from ISS on flights 8A, UF2, 9A, and 11A were analyzed for trace pollutants. On average, the air during this period of operations was safe for human respiration. However, about 3 hours into the regeneration of 2 Metox canisters in the U.S. airlock on 20 February 2002 the crew reported an intolerable odor that caused them to stop the regeneration, take refuge in the Russian segment, and scrub air in the U.S. segment for 30 hours. Analytical data from grab samples taken during the incident showed that the pollutants released were characteristic of nominal air pollutants, but were present in much higher concentrations. The odors reported by the crew were due to relatively high concentrations of n-butanol, and possibly other pollutants in the mixture. Later data taken during regeneration of Metox canisters that had not been subject to long-term flows showed minimal effects on air quality. Long-term trending data suggest that a disruption in atmospheric mixing between the Service Module and the U.S. Laboratory has occurred and that formaldehyde concentrations are gradually increasing in the U.S. Laboratory. Trending data also show that the releases of octafluoropropane (OFP) have subsided.

James, John T.↗

Toxicological Assessment of the International Space Station Atmosphere from Mission 5A to 8A

There are many sources of air pollution that can threaten air quality during space missions. The International Space Station (ISS) is an extremely complex platform that depends on a multi-tiered strategy to control the risk of excessive air pollution. During the seven missions surveyed by th is report, the ISS atmosphere was in a safe, steady-state condition; however, there were minor loads added as new modules were attached. There was a series of leaks of octafluoropropane, which is not directly toxic to humans, but did cause changes in air purification operations that disrupted the steady state condition . In addition, off-nominal regeneration of metal oxide canisters used during extravehicular activity caused a serious pollution incident.

James, John T.↗

A Second-Generation Volatile Organic Analyzer for the International Space Station

Early in the development of the Crew Health Care System (CHECS) for the International Space Station (ISS), it was recognized that detection of target volatile organic compounds would be a key component of the air monitoring strategy. Experiences during the NASA/Mir program supported the decision to include a real-time volatile organic analyzer (VOA) aboard ISS to help assess the impact of air quality events on crew health and determine the effectiveness of decontamination efforts. Toward this end, a joint development by the Toxicology Laboratory at Johnson Space Center and Graseby Dynamics produced a VOA that has been delivered and is ready for the first 5 years of ISS operation. The first-generation VOA selection criteria included minimizing size, weight, and power consumption while maintaining analytical performance. Measuring available technologies against these criteria, a VOA system based upon gas chromatography/ion mobility spectrometry (GC/IMS) was selected in the mid-90's. However, as NASA looks forward to later-stage ISS operations and to new frontiers such as human exploration of Mars, the ISS VOA (weighing 43 kg and consuming 160 watts) must be replaced by a smaller, less resource-intensive device. This paper will present a possible second-gene ration VOA based upon the same technology as the first-generation unit. Utilizing GC/IMS technology again will permit the instrumental data and experience gained during the initial phase of ISS to be applied to later ISS phases and advanced spacecraft missions. During the past 3 years, efforts to reduce the size of ion mobility spectrometers have been pursued by Graseby Dynamics, the manufacturer of the first-generation VOA. The concept of operation, expected analytical performance, and estimated size of a fully functional second-generation VOA based upon GC/mini-IMS technology will be presented. Furthermore, results of initial laboratory evaluations will be shown.

Limero, Thomas↗

Evaluation of Gas Chromatography/Mini-IMS to Detect VOCs

The Toxicology Laboratory at Johnson Space Center (JSC) has pioneered the use of gas chromatography-ion mobility spectrometry (GC/IMS) for measuring target volatile organic compounds (VOCs) aboard spacecraft. Graseby Dynamics, under contract to NASA/Wyle, has built several volatile organic analyzers (VOA) based on GC/IMS. Foremost among these have been the volatile organic analyzer-risk mitigation unit and the two flight VOA units for International Space Station (ISS). The development and evaluation of these instruments has been chronicled through presentations at the International Conference on Ion Mobility Spectrometry over the past three years. As the flight VOA from Graseby is prepared for operation on ISS at JSC, it is time to begin evaluations of technologies for the next generation VOA, Although the desired instrument characteristics for the next generation unit are the same as the current unit, the requirements are much more stringent. As NASA looks toward future missions beyond Earth environs, a premium will be placed upon small, light, reliable, autonomous hardware. It is with these visions in mind that the JSC Toxicology Laboratory began a search for the next generation VOA. One technology that is a candidate for the next generation VOA is GC/IMS. The recent miniaturization of IMS technology permits it to compete with other, inherently small, technologies such as chip-sized sensor arrays. This paper will discuss the lessons learned from the VOA experience and how that has shaped the design of a potential second generation VOA based upon GC/IMS technology. Data will be presented from preliminary evaluations of GC technology and the mini-IMS when exposed to VOCs likely to be detected aboard spacecraft. Results from the evaluation of an integrated GC/mini-IMS system will be shown if available.

Limero, Thomas↗