Search NASA⌕ Search

Engineering topics

Peterson, L.

Publications and source records attributed to Peterson, L..

Statistical data analysis of x-ray spectroscopy data enabled by neural network accelerated Bayesian inference

Bayesian inference applied to x-ray spectroscopy data analysis enables uncertainty quantification necessary to rigorously test theoretical models. However, when comparing to data, detailed atomic physics and radiation transfer calculations of x-ray emission from non-uniform plasma conditions are typically too slow to be performed in line with statistical sampling methods, such as Markov Chain Monte Carlo sampling. Furthermore, differences in transition energies and x-ray opacities often make direct comparisons between simulated and measured spectra unreliable. Here, we present a spectral decomposition method that allows for corrections to line positions and bound–bound opacities to best fit experimental data, with the goal of providing quantitative feedback to improve the underlying theoretical models and guide future experiments. In this work, we use a neural network (NN) surrogate model to replace spectral calculations of isobaric hot-spots created in Kr-doped implosions at the National Ignition Facility. The NN was trained on calculations of x-ray spectra using an isobaric hot-spot model post-processed with Cretin, a multi-species atomic kinetics and radiation code. The speedup provided by the NN model to generate x-ray emission spectra enables statistical analysis of parameterized models with sufficient detail to accurately represent the physical system and extract the plasma parameters of interest.

47 OTHER INSTRUMENTATION↗

An observation of annihilation radiation from the Galactic center region

Results are reported from observations of the 511 MeV annihilation gamma-ray line from the Galactic center, made on May 22, 1989 with a high-resolution gamma-ray spectrometer on board a balloon launched from Alice Springs (Australia). The observations were made at about 4 gm/sq cm atmospheric depth for 6 hrs in a series of target and background pointings lasting 20 min each. The results obtained from multiparameter Gaussian fits to the data were as follows: 511 keV flux = 0.00089 + or - 0.00027 ph/sq cm per sec-rad, line width of about 1.1 keV, and less than 3.2 keV FWHM at 95 percent confidence.

Matteson, J.↗

An observation of the Galactic center region with the HEXAGONE high resolution gamma-ray spectrometer

The Galactic center region was observed for 6 hours on May 22, 1989 from a high altitude balloon with the HEXAGONE high resolution gamma-ray spectrometer. The instrument had a 285 sq/cm array of cooled germanium detectors with an energy resolution of 2.2 keV at 511 keV and an 18 deg FWHM field of view. The 511 keV gamma-rays from electron-positron annihilation and 1809 keV gamma-rays from the radioactive decay of Al-26 were observed to have fluxes of 8.9 x 10 exp -4 and 1.9 x 10 exp -4 ph/cm-s, respectively. Continuum emission was detected from 20 to 800 keV and preliminary results have been obtained for the spectrum. Below 120 keV this is well described by power law with a slope of -2.6. In the 120-250 keV band the spectrum contains a broad linelike feature. This is interpreted as the result of Compton backscattering of about 511 keV photons from a compact source of electron-positron annihilation radiation.

Matteson, J.↗