Search NASA⌕ Search

Engineering topics

Peterson, R. C.

Publications and source records attributed to Peterson, R. C..

Radial velocities of stars in the globular cluster M4 and the cluster distance

The internal stellar velocity distribution of the globular cluster M4 is evaluated from nearly 200 new radial velocity measurements good to 1 km/s and a rederivation of existing proper motions. The mean radial velocity of the cluster is 70.9 +/- 0.6 km/s. The velocity dispersion is 3.5 +/- 0.3 km/s at the core, dropping marginally towards the outskirts. Such a low internal dispersion is somewhat at odds with the cluster's orbit, for which the perigalacticon is sufficiently close to the galactic center that the probability of cluster disruption is high; a tidal radius two-thirds the currently accepted value would eliminate the discrepancy. The cluster mass-to-light ratio is also small, M/L(sub V) = 1.0 +/- 0.4 in solar units. M4 thus joins M22 as a cluster of moderate and concentration with a mass-to-light ratio among the lowest known. The astrometric distance to the cluster is also smaller than expected, 1.72 +/- 0.14 kpc. This is only consistent with conventional estimates of the luminosity of horizontal branch stars provided an extinction law R = A(sub V)/E(B-V) approximately 4 is adopted, as has been suggested recently by several authors.

Peterson, R. C.↗

Large-aperture high-resolution X-ray collimator for the Solar Maximum Mission

A description is presented of a flight-qualified large-aperture 12 x 12-arcsec angular resolution multigrid X-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4-22.4-A wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. The grids are of a compound and bimetallic design, having 63.5-micron square holes on an 88.9-micron spacing in 8-micron thick gold, which is in turn supported by a 76-micron thick Invar grid having 600-micron square holes on a 739-micron spacing. The small apertures in the gold provide the 12-arcsec collimation with the Invar grids providing wide angle off-axis blocking out to an approximately 35 arcmin view angle. The collimator has seven individual channels, four of a 5.1- x 10-cm area and three of a 1.3- x 10-cm area. Laboratory measurements gave an average angular resolution of 12.5 arcsec FWHM with 0.259 transmission for the large-area channels and 12.0 arcsec and 0.200 transmission for the small-area channels. A thermal filter composed of two layers of approximately 1000-A thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the X radiation in the band of interest.

Nobles, R. A.↗

Total reduction of distorted echelle spectrograms - An automatic procedure

A total reduction procedure, notable for its use of a computer-controlled microdensitometer for semi-automatically tracing curved spectra, is applied to distorted high-dispersion echelle spectra recorded by an image tube. Microdensitometer specifications are presented and the FORTRAN, TRACEN and SPOTS programs are outlined. The intensity spectrum of the photographic or electrographic plate is plotted on a graphic display. The time requirements are discussed in detail.

Peterson, R. C.↗