Search NASA⌕ Search

Engineering topics

Petrasso, R. D.

Publications and source records attributed to Petrasso, R. D..

At least 37 records · Page 2

A magnetic particle time-of-flight (MagPTOF) diagnostic for measurements of shock and compression-bang time at the NIF [National Ignition Facility]

A magnetic particle time-of-flight (MagPTOF) diagnostic has been designed to measure shock- and compression-bang time using DHe-fusion protons and DD-fusion neutrons, respectively, at the National Ignition Facility (NIF). This capability, in combination with shock-burn weighted areal density measurements, will significantly constrain the modeling of the implosion dynamics. This design is an upgrade to the existing particle time-of-flight (pTOF) diagnostic, which records bang times using DD or DT neutrons with an accuracy better than ±70 ps [H. G. Rinderknecht et al., Rev. Sci. Instrum. 83, 10D902 (2012)]. The inclusion of a deflecting magnet will increase DHe-proton signal-to-background by a factor of 1000, allowing for the first time simultaneous measurements of shock and compression-bang times in DHe-filled surrogate implosions at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Yield degradation due to laser drive asymmetry in D 3 He backlit proton radiography experiments at OMEGA

Mono-energetic proton radiography is a vital diagnostic for numerous high-energy-density-physics, inertial-confinement-fusion, and laboratory-astrophysics experiments at OMEGA. With a large number of campaigns executing hundreds of shots, general trends in D 3 He backlighter performance are statistically observed. Each experimental configuration uses a different number of beams and drive symmetry, causing the backlighter to perform differently. Here, we analyze the impact of these variables on the overall performance of the D 3 He backlighter for proton-radiography studies. This study finds that increasing laser drive asymmetry can degrade the performance of the D 3 He backlighter. The results of this study can be used to help experimental designs that use proton radiography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An x-ray penumbral imager for measurements of electron–temperature profiles in inertial confinement fusion implosions at OMEGA

Hot-spot shape and electron temperature (T e ) are key performance metrics used to assess the efficiency of converting shell kinetic energy into hot-spot thermal energy in inertial confinement fusion implosions. X-ray penumbral imaging offers a means to diagnose hot-spot shape and T e , where the latter can be used as a surrogate measure of the ion temperature (T i ) in sufficiently equilibrated hot spots. We have implemented a new x-ray penumbral imager on OMEGA. We demonstrate minimal line-of-sight variations in the inferred T e for a set of implosions. Furthermore, we demonstrate spatially resolved T e measurements with an average uncertainty of 10% with 6 μm spatial resolution.

47 OTHER INSTRUMENTATION↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Using millimeter-sized carbon-deuterium foils for high-precision deuterium-tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA laser facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils better characterized, and impact of uncontrolled foil motion prior to detection investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗

Response of CR-39 nuclear track detectors to protons with non-normal incidence

This paper presents data from experiments with protons at non-normal incidence to CR-39 nuclear track detectors, analyzing the properties of detection efficiency, proton track diameter, track contrast, and track eccentricity. Understanding the CR-39 response to protons incident at an angle is important for designing charged particle detectors for inertial confinement fusion (ICF) applications. This study considers protons with incident energies less than 3 MeV. In this regime, an incident angle of 10° has no effect on CR-39 detection efficiency, and >85% detection efficiency is preserved up through 25° in the range of 1.0 MeV–2.1 MeV. For ICF applications, incident angles above 30° are deemed impractical for detector design due to significant drops in proton detection at all energies. We observe significant reductions in detection efficiency compared to theoretical predictions, particularly at low energies where proton tracks are etched away. The proton track diameter measured by the scan system is observed to decrease with higher incident angles. The track diameters are analyzed with two fitting models, and it is shown that the diameter–energy relation can be fit with the existing models at angles up to 30° . The optical contrast of the tracks tends to increase with the angle, meaning that the tracks are fainter, and a larger increase is observed for higher energies. Eccentricity, a measure of how elongated proton tracks are, increases with the incident angle and drops after the critical angle. The lowest energy tracks remain nearly circular even at higher angles.

47 OTHER INSTRUMENTATION↗

A neutron recoil-spectrometer for measuring yield and determining liner areal densities at the Z facility

For this study, a proof-of-principle CR-39 based neutron-recoil-spectrometer was built and fielded on the Z facility. Data from this experiment match indium activation yields within a factor of 2 using simplified instrument response function (IRF) models. The data also demonstrates the need for neutron shielding in order to infer liner areal densities. A new shielded design has been developed. The spectrometer is expected to achieve signal-to-background greater than 2 for the down-scattered neutron signal and greater than 30 for the primary signal.

47 OTHER INSTRUMENTATION↗

Platform development for dE/dx measurements on short-pulse laser facilities

We illustrate generating benchmark data on charged-particle stopping power in dense plasma is a challenge, motivating new experimental platforms for facilities such as short-pulse lasers. We report on several experiments that aimed to develop a platform for high-precision stopping power measurements at OMEGA EP, specifically developing target-normal sheath acceleration (TNSA) sources, proton isochoric heating, and radiatively heated foams. Integrated experiments were performed to measure stopping power, but several phenomena have been identified that would need to be mitigated for a stopping-power measurement, including irreproducibility of the TNSA sources, spurious electromagnetic fields around proton-heated targets, and cross-talk between the source and subject targets. This work provides a basis for potential future work towards mitigating these problems and performing stopping-power measurements, and is also valuable data for general understanding of TNSA and proton isochoric heating experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D xRAGE simulation of inertial confinement fusion implosion with imposed mode 2 laser drive asymmetry

Low-mode asymmetries represent an important obstacle to achieving high-gain inertial confinement fusion implosions. As a step in learning how to control such effects, an OMEGA experiment with imposed mode 2 laser drive asymmetries was done to study the expected signatures of this type of asymmetry [M. Gatu Johnson et al., PRE 2018]. In the present work, a 3D xRAGE simulation including the stalk mount has been brought to bear on the data from that experiment. Furthermore, comprehensive comparisons between simulated and measured observables are made. Good agreement between simulated and measured x-ray image-inferred shell trajectories, bang times and neutron emission widths are seen, showing that the hydrodynamics are well captured in the simulation. Asymmetries seen in simulated and measured time-resolved and time-integrated x-ray images and areal densities also compare well, showing impact of both stalk and mode 2. On the other hand, important differences in measured and simulated neutron emission histories, yield, and ion temperature (T ion ) asymmetries are seen, suggesting that the simulation is overestimating shock yield. Overall, the results clearly demonstrate the importance of considering all asymmetry sources when interpreting measured signatures of asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CR-39 nuclear track detector response to inertial confinement fusion relevant ions

The detection properties of CR-39 were investigated for protons, deuterons, and tritons of various energies. Two models for the relationship between the track diameter and particle energy are presented and demonstrated to match experimental data for all three species. Data demonstrate that CR-39 has 100% efficiency for protons between 1 MeV and 4 MeV, deuterons between 1 MeV and 12.2 MeV, and tritons between 1 MeV and 10 MeV. The true upper bounds for deuterons and tritons exceed what could be measured in data. Simulations were developed to further explore the properties of CR-39 and suggest that the diameter–energy relationship of alpha particles cannot be captured by the conventional c-parameter model. These findings provide confidence in CR-39 track diameter based spectroscopy of all three species and provide invaluable insight for designing filtering for all CR-39 based diagnostics.

47 OTHER INSTRUMENTATION↗

2 H(p,γ) 3 He cross section measurement using high-energy-density plasmas

An absolute cross section for the radiative capture reaction 2 H(p,γ) 3 He has been measured at the OMEGA laser facility using inertially confined plasmas. These high-temperature plasmas are created by imploding a fuel-containing capsule using laser ablation, and are advantageous in that they better mimic astrophysical systems. We measure an S factor for this reaction of 0.429 ± 0.026 stat ± 0.072 sys eV b at E c.m . = 16.35 ± 0.40 keV, which is higher than the adopted evaluations. Furthermore, this reaction is important as a source of nuclear energy in protostars and brown dwarfs. It is also a critical reaction during big-bang nucleosynthesis, and an accurate cross section can be used as a constraint on cosmology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of stalk on directly driven inertial confinement fusion implosions

Low-mode asymmetries have emerged as one of the primary challenges to achieving high-performing inertial confinement fusion (ICF) implosions. In direct-drive ICF, an important potential seed of such asymmetries is the capsule stalk mount, the impact of which has remained a contentious question. In this paper, we describe the results from an experiment on the OMEGA laser with intentional offsets at varying angles to the capsule stalk mount, which clearly demonstrates the impact of the stalk mount on implosion dynamics. The angle between stalk and offset is found to significantly impact observables. Specifically, a larger directional flow is observed in neutron spectrum measurements when the offset is toward rather than away from the stalk, while an offset at 42° to the stalk gives minimal directional flow but still generates a large flow field in the implosion. No significant directional flow is seen due to stalk only. Time-integrated x-ray images support these flow observations. A trend is also seen in implosion yield, with lower yield obtained for offsets with a smaller angle than with a larger angle toward the stalk. Radiation hydrodynamic simulations using 2D DRACO and 2D/3D Chimera not including the stalk mount and using 2D xRAGE including the stalk mount are brought to bear on the data. The yield trend, the minimal directional flow with stalk only, and the larger flow enhancement observed with the offset toward the stalk are all reproduced in the xRAGE simulations. Finally, the results strongly indicate that the stalk impact must be considered and mitigated to achieve high-performing implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A radiation belt monitor for the High Energy Transient Experiment Satellite

A Radiation Belt Monitor (RBM) sensitive to protons and electrons with energy approximately greater than 0.5 MeV has been designed for the High Energy Transient Experiment (HETE) satellite in order to: first, control the on-off configuration of the experiments (i.e. those susceptible to proton damage); and second, to indicate the presence of proton and/or electron events that could masquerade as legitimate high energy photon events. One of the two RBM channels has an enhanced sensitivity to electrons. Each channel of the RBM, based on a PIN silicon diode, requires a typical power of 6 milliwatts. Tests have been performed with protons with energies from approximately 0.1 to 2.5 MeV (generated by a Cockcroft-Walton linear accelerator via the d(d,p)t reaction), and with electrons with energies up to 1 MeV (from a 1.0 microcurie Bi-207 source).

Lo, D. H.↗

Study of the post-flare loops on 29 July 1973. IV - Revision of T and n sub e values and comparison with the flare of 21 May 1980

Revised temperature and density estimates are provided in a synthesis of previous studies of the two-ribbon solar flare of July 29, 1973 and results are compared with observations of a similar event by the Solar Maximum Mission on May 21, 1980. Photographs taken through X ray filters permitted determination of the spatial distribution of temperature and density in the loop system and variations over time. The entire growth process of the flare is detailed, including the magnetic field configurations and the enlargement of the Halpha flare ribbon separation distance. The temperature is revised to 8.8 million K during maximum soft X ray emission and 6.8 million K at the appearance of the last Halpha loops. The 1973 flare is noted to have occurred in an old, decaying spotless region, producing higher loops at lower density than the 1980 flare, which displayed ribbons imbedded in a sunspot group.

Svestka, Z.↗

Study of the post-flare loops on 29 July 1973. I - Dynamics of the X-ray loops

We derive an empirical model of the X-ray emitting post-flare loops observed during the decay phase of the 29 July 1973 flare. We find that the loops are elliptical, with the brightest emitting region at the tops. We determine the height, velocity of growth, and ratio of height to width of the loops at times from 3 to 12 hr after the flare onset.

Nolte, J. T.↗

Study of the post-flare loops on 29 July 1973. II - Physical parameters in the X-ray loops

We use the filter ratio method of analysis to determine spatially resolved values of plasma parameters in the X-ray emitting post-flare loop system which developed on 29 and 30 July 1973. We find that the loops were hotter and had higher plasma pressure at their tops than near their footpoints. The loop tops were at nearly the same temperature at different places 3 hr after the flare maximum and were also at nearly this same temperature 3 and 8 hr later. Variations in brightness transverse to the loops were due to variations in emission measure. We show by consideration of radiative losses alone that energy must have been added to the hottest part of the flare, at the tops of the loops, late in the decay phase of the flare.

Petrasso, R. D.↗

Do changes in coronal emission structure imply magnetic reconnection

Several physical processes that can affect the emission from structures in the corona are investigated on the basis of images of coronal X-ray and XUV emission structures. Changes in emission accompanied by little or no change in large-scale magnetic structure are examined, and three theoretically distinct processes by which magnetic structure can change are discussed: reconfiguration of potential (current-free) fields, reconfiguration of frozen-in fields, and reconfiguration by magnetic-field-line reconnection. The possibility is considered of determining by observation whether a change in emission results from a magnetic change and, if so, what kind of magnetic change has occurred. It is concluded that changes in coronal emission structure do not necessarily imply magnetic reconnection.

Nolte, J. T.↗