Search NASA⌕ Search

Engineering topics

Pfeiffer, F.

Publications and source records attributed to Pfeiffer, F..

Note: Gratings on low absorbing substrates for x-ray phase contrast imaging

Grating based X-ray phase contrast imaging is on the verge of being applied in clinical settings. To achieve this goal, compact setups with high sensitivity and dose efficiency are necessary. Both can be increased by eliminating unwanted absorption in the beam path, which is mainly due to the grating substrates. Fabrication of gratings via deep X-ray lithography can address this issue by replacing the commonly used silicon substrate with materials with lower X-ray absorption that fulfill certain boundary conditions. Gratings were produced on both graphite and polymer substrates without compromising on structure quality. These gratings were tested in a three-grating setup with a source operated at 40 kVp and lead to an increase in the detector photon count rate of almost a factor of 4 compared to a set of gratings on silicon substrates. As the visibility was hardly affected, this corresponds to a significant increase in sensitivity and therefore dose efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray grating interferometry at photon energies over 180 keV

We report on the implementation and characterization of grating interferometry operating at an x-ray energy of 183 keV. With the possibility to use this technique at high x-ray energies, bigger specimens could be studied in a quantitative way. Also, imaging strongly absorbing specimens will benefit from the advantages of the phase and dark-field signals provided by grating interferometry. However, especially at these high photon energies the performance of the absorption grating becomes a key point on the quality of the system, because the grating lines need to keep their small width of a couple of micrometers and exhibit a greater height of hundreds of micrometers. The performance of high aspect ratio absorption gratings fabricated with different techniques is discussed. Further, a dark-field image of an alkaline multicell battery highlights the potential of high energy x-ray grating based imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental comparison of grating- and propagation-based hard X-ray phase tomography of soft tissue

When imaging soft tissues with hard X-rays, phase contrast is often preferred over conventional attenuation contrast due its superior sensitivity. However, it is unclear which of the numerous phase tomography methods yields the optimized results at given experimental conditions. Therefore, we quantitatively compared the three phase tomography methods implemented at the beamline ID19 of the European Synchrotron Radiation Facility: X-ray grating interferometry (XGI), and propagation-based phase tomography, i.e., single-distance phase retrieval (SDPR) and holotomography (HT), using cancerous tissue from a mouse model and an entire heart of a rat. We show that for both specimens, the spatial resolution derived from the characteristic morphological features is about a factor of two better for HT and SDPR compared to XGI, whereas the XGI data generally exhibit much better contrast-to-noise ratios for the anatomical features. Moreover, XGI excels in fidelity of the density measurements, and is also more robust against low-frequency artifacts than HT, but it might suffer from phase-wrapping artifacts. Thus, we can regard the three phase tomography methods discussed as complementary. The application will decide which spatial and density resolutions are desired, for the imaging task and dose requirements, and, in addition, the applicant must choose between the complexity of the experimental setup and the one of data processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative electron density characterization of soft tissue substitute plastic materials using grating-based x-ray phase-contrast imaging

Many scientific research areas rely on accurate electron density characterization of various materials. For instance in X-ray optics and radiation therapy, there is a need for a fast and reliable technique to quantitatively characterize samples for electron density. We present how a precise measurement of electron density can be performed using an X-ray phase-contrast grating interferometer in a radiographic mode of a homogenous sample in a controlled geometry. A batch of various plastic materials was characterized quantitatively and compared with calculated results. We found that the measured electron densities closely match theoretical values. The technique yields comparable results between a monochromatic and a polychromatic X-ray source. Measured electron densities can be further used to design dedicated X-ray phase contrast phantoms and the additional information on small angle scattering should be taken into account in order to exclude unsuitable materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark-field X-ray imaging of unsaturated water transport in porous materials

We introduce in this Letter an approach to X-ray imaging of unsaturated water transport in porous materials based upon the intrinsic X-ray scattering produced by the material microstructural heterogeneity at a length scale below the imaging system spatial resolution. The basic principle for image contrast creation consists in a reduction of such scattering by permeation of the porosity by water. The implementation of the approach is based upon X-ray dark-field imaging via Talbot-Lau interferometry. The proof-of-concept is provided by performing laboratory-scale dark-field X-ray radiography of mortar samples during a water capillary uptake experiment. The results suggest that the proposed approach to visualizing unsaturated water transport in porous materials is complementary to neutron and magnetic resonance imaging and alternative to standard X-ray imaging, the latter requiring the use of contrast agents because based upon X-ray attenuation only.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ptychography with broad-bandwidth radiation

Ptychography, a scanning Coherent Diffractive Imaging (CDI) technique, has quickly gained momentum as a robust method to deliver quantitative images of extended specimens. A current conundrum for the development of X-ray CDI is the conflict between a need for higher flux to reach higher resolutions and the requirement to strongly filter the incident beam to satisfy the tight coherence prerequisite of the technique. Latest developments in algorithmic treatment of ptychographic data indicate that the technique is more robust than initially assumed, so that some experimental limitations can be substantially relaxed. Here, we demonstrate that ptychography can be conducted in conditions that were up to now considered insufficient, using a broad-bandwidth X-ray beam and an integrating scintillator-based detector. Our work shows the wide applicability of ptychography and paves the way to high-throughput, high-flux diffractive imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural optimization with constraints from dynamics in Lagrange

Structural optimization problems are mostly solved under constraints from statics, such as stresses, strains, or displacements under static loads. But in the design process, dynamic quantities like eigenfrequencies or accelerations under dynamic loads become more and more important. Therefore, it is obvious that constraints from dynamics must be considered in structural optimization packages. This paper addresses the dynamics branch in MBB-LAGRANGE. It will concentrate on two topics, namely on the different formulations for eigenfrequency constraints and on frequency response constraints. For the latter the necessity of a system reduction is emphasized. The methods implemented in LAGRANGE are presented and examples are given.

Pfeiffer, F.↗